Entropy generation and exergy analysis of Ag-MgO/water hybrid nanofluid within a circular heatsink with different number of outputs
被引:31
作者:
Aghakhani, Saeed
[1
]
Pordanjani, Ahmad Hajatzadeh
[2
]
Afrand, Masoud
[1
]
Farsani, Ayoob Khosravi
[3
]
Karimi, Nader
[4
]
Sharifpur, Mohsen
[5
,6
]
机构:
[1] Islamic Azad Univ, Dept Mech Engn, Najafabad Branch, Najafabad, Iran
[2] Shahid Chamran Univ Ahvaz, Dept Mech Engn, Ahvaz, Iran
[3] Tech & Vocat Univ TVU, Dept Mech Engn, Tehran, Iran
[4] Queen Mary Univ London, Sch Engn & Mat Sci, London E1 4NS, England
[5] Univ Pretoria, Dept Mech & Aeronaut Engn, ZA-0002 Pretoria, South Africa
[6] China Med Univ, China Med Univ Hosp, Dept Med Res, Taichung, Taiwan
关键词:
Circular heatsink;
Hybrid nanofluid;
Entropy;
Exergy;
BIOLOGICAL NANOFLUID;
TRANSFER ENHANCEMENT;
FORCED-CONVECTION;
SINK;
FLOW;
WATER;
PERFORMANCE;
CHANNEL;
BLOCK;
D O I:
10.1016/j.ijthermalsci.2022.107891
中图分类号:
O414.1 [热力学];
学科分类号:
摘要:
This paper presents a thermodynamic analysis of a mini circular heatsink (HS). The investigated HS features four different types with a varying number of outputs and Ag-MgO/water hybrid nanofluid (NF) as the working fluid. In different types of HSs, the number of doors created between the parts of HSs is different. Computational and experimental analyses of this system are conducted to examine the first and second law efficiencies. A physical model of the HSs is, firstly, fabricated and tested for various flow rates. Numerical simulations are then performed using a finite element method. By changing the Reynolds number (Re) and the volume fraction of nanoparticles (phi) for all types of the HS, entropy generation (EnG) and exergy losses are evaluated. The results show that the copper HS could perform more cooling than the aluminum HS. Further, an increment in the Re substantiates thermal EnG (S-Th)and reduces the frictional EnG (S-F), which ultimately reduces the total EnG rate (S-Tot). Yet, the addition of phi slightly enhances EnG. Among the investigated types of HSs, the 4-door type features the lowest EnG. An enhancement in the Re leads to a reduction in the exergy loss as well as the first and second law efficiencies. It is concluded that the addition of phi does not make any favorable effect on the system thermodynamics, as it amplifies EnG, and boosts the losses. An increase of 2% of nanoparticles reduces the maximum the first and second law efficiencies of system by 5.6% and 2.5%, respectively.