Effect of compact thermosyphon height on boiling curve and thermal performance: A visualization analysis

被引:8
作者
Qin, Siyu [1 ]
Liu, Yijia [1 ]
Ji, Ruiyang [1 ,3 ]
Zhang, Haitao [1 ]
Jin, Liwen [1 ]
Yang, Chun [2 ]
Meng, Xiangzhao [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Bldg Environm & Sustainabil Technol, Sch Human Settlements & Civil Engn, Xian 710049, Peoples R China
[2] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
[3] Virginia Tech, Dept Mech Engn, Blacksburg, VA 24061 USA
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Thermal management; Compact thermosyphon; Bubble dynamics; Boiling curve; Thermal performance; CHANGE HEAT-TRANSFER; THIN VAPOR CHAMBER; LOOP THERMOSIPHON; COOLING SYSTEM; PART; PIPE; FLUX; CONFINEMENT; CONDENSER; DESIGN;
D O I
10.1016/j.applthermaleng.2023.122142
中图分类号
O414.1 [热力学];
学科分类号
摘要
The thermal management requirement of the servers for data centers has become an urgent issue to be addressed. The two-phase compact thermosyphon has been one of the highly-efficient passive cooling devices to solve heat dissipation problems. In this study, compact thermosyphons with different heights (20 mm, 25 mm, and 50 mm) and filling ratios (25 % - 75 %) were investigated. The corresponding boiling curves and thermal performance were analyzed. Thermal resistance was defined to evaluate the thermal performance in the thermosyphon system. The experimental results illustrate that the reduction in height significantly influences the thermal behaviors of the compact thermosyphon. For the 20 mm height case, the bubble adheres to the condensation surface for a longer time compared with the other cases, which increases the entire bubble growth period. Boiling curves of compact thermosyphons with different heights and filling ratios exhibit distinct characteristics. The heat flux on the boiling surface (qb) with 20 mm height at the low filling ratio (FR = 25 %) is 68.2 % of that with the 50 mm height, indicating the reduced boiling intensity. Both the delayed onset of boiling (ONB) and bubble films of large areas on the condensation surface are generated at FR = 75 % case with 20 mm height, which weakens the phase change heat transfer. For the 50 mm height case, a medium filling ratio and lower input heat flux provide the optimized performance (0.36 K & sdot;W- 1 of the thermal resistance). For the compact thermosyphon with lower height, low and medium filling ratios are preferred to minimize the deterioration of thermal performance. The outcomes are hoped to provide references for the optimal design and operation of the compact thermosyphon applied in the areas of thermal management and energy conservation.
引用
收藏
页数:15
相关论文
共 49 条
[21]   Thermal performance of a novel flat thermosyphon for avionics thermal management [J].
Junior, Antonio A. M. ;
Mantelli, Marcia B. H. .
ENERGY CONVERSION AND MANAGEMENT, 2019, 202
[22]   A predictive model for confined and unconfined nucleate boiling heat transfer coefficient [J].
Kiyomura, Igor Seicho ;
Mogaji, Taye Stephen ;
Manetti, Leonardo Lachi ;
Cardoso, Elaine Maria .
APPLIED THERMAL ENGINEERING, 2017, 127 :1274-1284
[23]   Enhancement of subcooled boiling in confined space using ultrasonic waves [J].
Li, Xiao ;
Tang, Jiguo ;
Sun, Licheng ;
Li, Jia ;
Bao, Jingjing ;
Liu, Hongli .
CHEMICAL ENGINEERING SCIENCE, 2020, 223
[24]   Visualization and heat transfer comparative analysis of two phase closed thermosyphon [J].
Liu, Hao ;
Gan, Wang ;
Yao, Huicong ;
Wang, Xiaoyuan ;
Wang, Yinfeng ;
Zhu, Yuezhao .
APPLIED THERMAL ENGINEERING, 2022, 217
[25]   Nucleate boiling inside small evaporating droplets: An experimental and numerical study [J].
Lu, Gui ;
Wang, Xiao-Dong ;
Yan, Wei-Mon .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 108 :2253-2261
[26]   An experimental investigation on the heat transfer characteristics of minichannel thermosyphon with multiports for cooling the modern miniaturized electronic devices [J].
Manova, Stephen ;
Asirvatham, Lazarus Godson ;
Appadurai, Anitha Angeline ;
Ribatski, Gherhardt ;
Kumar, Pradeep ;
Wongwises, Somchai .
ENERGY CONVERSION AND MANAGEMENT, 2022, 268
[27]   Air-Cooled Loop Thermosyphon Cooling System for High Heat Load CPUs-Part I: Design and Performance Simulation [J].
Marcinichen, Jackson B. ;
Armas, Guilherme S. R. B. ;
Rouaze, Gautier ;
Thome, John R. ;
Zhang, L. Winston .
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2021, 11 (10) :1679-1686
[28]   Nucleate boiling and critical heat flux of HFE-7100 in horizontal narrow spaces [J].
Misale, M. ;
Guglielmini, G. ;
Priarone, A. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2011, 35 (05) :772-779
[29]   Experimental investigation of a confined flat two-phase thermosyphon for electronics cooling [J].
Narcy, Marine ;
Lips, Stephane ;
Sartre, Valerie .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2018, 96 :516-529