Mercury determination in bioresorbable calcium phosphate using a new electrothermal vaporization system coupled to ICP-MS

被引:7
作者
Silva, Jussiane S. S. [1 ]
Heidrich, Graciela M. M. [1 ]
Poletto, Bruno O. O. [1 ]
Paniz, Jose N. G. [1 ]
Dressler, Valderi L. L. [1 ]
Flores, Erico M. M. [1 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
关键词
SAMPLE PREPARATION METHODS; PLASMA-MASS SPECTROMETRY; MULTIELEMENT ANALYSIS; ATOMIC-ABSORPTION; SPECIATION; EMISSION; ANALYZER(R); DIGESTION; ELEMENTS;
D O I
10.1039/d2ja00414c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A direct solid sampling method was developed for determining mercury in bioresorbable calcium phosphate-based materials by electrothermal vaporization (ETV) coupled to an inductively coupled plasma mass spectrometry (ICP-MS) instrument. The ETV system is based on fast sample heating using a halogen lamp enclosed in a glass chamber. The heating program comprises only a vaporization step (10 s) followed by a cooling step (120 s) when a solid sample was analyzed. An additional step of 20 s at 80 degrees C was necessary when aqueous solutions were used for calibration. Mercury was vaporized at a relatively low temperature (650 degrees C) without co-vaporizing the main matrix (more than 95% of the matrix remains in the lamp dimpled cavity). External calibration with aqueous reference solutions deposited on the sample residue was used for Hg quantification. The accuracy of the proposed method was evaluated by certified reference material analysis (MESS-3) and by pneumatic nebulization ICP-MS (NEB-ICP-MS), and no statistical difference was observed between the results. Relatively high masses (up to 10 mg) can be analyzed without interferences. The limit of quantification (0.2 ng g(-1)) by ETV-ICP-MS was lower than that by NEB-ICP-MS (60 ng g(-1)), the precision was better than 15% and the sample throughput was 20 per hour. Therefore, the proposed low-cost ETV system is attractive for determining Hg at the ultra-trace level in biomaterials and can be used for routine analyses.
引用
收藏
页码:1000 / 1006
页数:7
相关论文
共 38 条
  • [21] Total determination and direct chemical speciation of Hg in fish by solid sampling GF AAS
    Naozuka, Juliana
    Nomura, Cassiana Seimi
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (11) : 2257 - 2262
  • [22] Determination of Inorganic Contaminants in Electrical and Electronic Equipment after Digestion Using Microwave-Assisted Single Reaction Chamber
    Oliveira, Jussiane S. S.
    Krzyzaniak, Sindy R.
    Picoloto, Rochele S.
    Bolzan, Rodrigo C.
    Mello, Paola A.
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2017, 28 (09) : 1657 - 1664
  • [23] Evaluation of sample preparation methods for polymer digestion and trace elements determination by ICPMS and ICPOES
    Pereira, J. S. F.
    Knorr, C. L.
    Pereira, L. S. F.
    Moraes, D. P.
    Paniz, J. N. G.
    Flores, E. M. M.
    Knapp, G.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (09) : 1849 - 1857
  • [24] Determination of elemental impurities in poly(vinyl chloride) by inductively coupled plasma optical emission spectrometry
    Pereira, Leticia S. F.
    Pedrotti, Matheus F.
    Miceli, Tatiane M.
    Pereira, Juliana S. F.
    Flores, Erico M. M.
    [J]. TALANTA, 2016, 152 : 371 - 377
  • [25] Biomonitoring of essential and toxic elements in small biological tissues by ICP-MS
    Pozebon, Dirce
    Dressler, Valderi L.
    Becker, J. Susanne
    Matusch, Andreas
    Zoriy, Miroslav
    Becker, J. Sabine
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (09) : 1281 - 1284
  • [26] Ceramic biomaterials: Properties, state of the art and future prospectives
    Punj, Shivani
    Singh, Jashandeep
    Singh, K.
    [J]. CERAMICS INTERNATIONAL, 2021, 47 (20) : 28059 - 28074
  • [27] Ratner B., 2013, Biomaterials science
  • [28] Rde C. B., 2009, ARCH ENVIRON OCCUP H, V64, P266
  • [29] Electrothermal vaporization for sample introduction in atomic absorption, atomic emission and plasma mass spectrometry-a critical review with focus on solid sampling and slurry analysis
    Resano, M.
    Vanhaecke, F.
    de Loos-Vollebregt, M. T. C.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (11) : 1450 - 1475
  • [30] Multi-element analysis of a thermographic material by means of solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry
    Resano, M
    Balcaen, L
    Vanhaecke, F
    Moens, L
    Geuens, I
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (03) : 495 - 511