Development of correlations for predicting Nusselt number and friction factor of roughened solar air heater duct for sustainable development

被引:10
作者
Karmveer
Gupta, Naveen Kumar [1 ]
Alam, Tabish [2 ,3 ]
机构
[1] GLA Univ, Inst Engn & Technol, Mathura, India
[2] CSIR, Cent Bldg Res Inst, Architecture Planning & Energy Efficieny Div, Roorkee, India
[3] CSIR, Cent Bldg Res Inst, Roorkee 247667, India
关键词
Multiple Open Trapezoidal Rib (MOTR); heat transmission; absorber; solar air heater; roughness; PRESSURE-DROP PENALTY; ARC-SHAPED WIRE; TRANSFER ENHANCEMENT; RECTANGULAR DUCT; RIB ROUGHNESS; PERFORMANCE EVALUATION; THERMAL PERFORMANCE; FLUID-FLOW; TRANSVERSE; CHANNELS;
D O I
10.1080/08916152.2023.2189329
中图分类号
O414.1 [热力学];
学科分类号
摘要
The solar air heater (SAH), which utilizes solar energy to satisfy the building's heating demands, is an important integrated component of the building. However, SAH's performance isn't good enough for it to be used in building. Adding roughness component to the effective zone of heat transfer underneath the absorber plate is the most successful and efficient technique to augment the thermal performance of solar air heater (SAH). In this regards, artificial roughness consisting of several Multiple Open Trapezoidal Rib (MOTR) has been devised with intention of capitalizing on the benefits of secondary flows with regard to the improvement of heat transmission. The geometrical parameters of MOTRs such as relative limb length (L/w = 0.2-1.0), Reynold number (Re = 2000-16000), relative rib height (e/D-h = 0.023-0.054), and relative roughness pitch (p/e = 6-12) have been exploited, while relative width ratio (W/w = 6) and angle of attack (alpha = 60 degrees) are maintained constant in all the set of experiments. The highest augmentation in Nusselt number (Nu) is observed as 6.07 times as that of smooth absorber plate. In addition, following empirical correlations have been developed for Nu & f with accuracy of average absolute deviation of 5.47% and 5.02%, respectively.
引用
收藏
页码:704 / 722
页数:19
相关论文
共 48 条
[1]   Experimental investigation on heat transfer enhancement due to V-shaped perforated blocks in a rectangular duct of solar air heater [J].
Alam, Tabish ;
Saini, R. P. ;
Saini, J. S. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 81 :374-383
[2]   Experimental investigation of solar air heater with new symmetrical GAP ARC GEOMETRY and staggered element [J].
Ambade, Jaigopal ;
Lanjewar, Atul .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 146
[3]   Influence of stepped cylindrical turbulence generators on the thermal enhancement factor of a flat plate solar air heater [J].
Antony, A. Leander ;
Shetty, Shreyas P. ;
Madhwesh, N. ;
Sharma, N. Yagnesh ;
Karanth, K. Vasudeva .
SOLAR ENERGY, 2020, 198 :295-310
[4]  
Ashrae, 1977, 9397 REFR AIR COND E
[5]   Numerical and experimental study of the heat transfer and hydraulic performance of solar air heaters with different baffle positions [J].
Bensaci, Charaf-Eddine ;
Moummi, Abdelhafid ;
Sanchez de la Flor, Francisco J. ;
Rodriguez Jara, Enrique A. ;
Rincon-Casado, Alejandro ;
Ruiz-Pardo, Alvaro .
RENEWABLE ENERGY, 2020, 155 :1231-1244
[6]   Heat transfer enhancement and pressure drop penalty in porous solar heaters: Numerical simulations [J].
Bovand, M. ;
Rashidi, S. ;
Esfahani, J. A. .
SOLAR ENERGY, 2016, 123 :145-159
[7]   Thermal performance of tubular heat exchanger with multiple twisted-tape inserts [J].
Chokphoemphun, Suriya ;
Pimsarn, Monsak ;
Thianpong, Chinaruk ;
Promvonge, Pongjet .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2015, 23 (05) :755-762
[8]  
Han J. C., 1991, J HEAT TRANS-T ASME, V35, P513, DOI [10.1016/0017-9310(92)90286-2, DOI 10.1016/0017-9310(92)90286-2]
[9]   Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs [J].
Hans, V. S. ;
Saini, R. P. ;
Saini, J. S. .
SOLAR ENERGY, 2010, 84 (06) :898-911
[10]  
Holman J.P., 2004, Experimental methods for engineers