Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism

被引:1
作者
Jin, Tianru [1 ]
Yu, Lan [1 ]
Li, Jingjing [1 ]
Zhou, Yanwen [1 ]
机构
[1] Shenyang Aier Eye Optometry Hosp, Dept Cataract Surg, Shenyang, Peoples R China
关键词
Posterior corneal astigmatism; refractive surgery; toric IOL; total corneal astigmatism; ANTERIOR; POPULATION; SURFACE;
D O I
10.4103/IJO.IJO_3385_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate whether the toric intra-ocular lens (IOL) power calculation based on total corneal astigmatism (TCA) in eyes with high posterior corneal astigmatism (PCA) could result in a systematic over-correction or under-correction after operation. Methods: The present study included a mono-centric retrospective study design. The data were collected from 62 consecutive eyes during uncomplicated cataract surgery by a single surgeon with a measured PCA of 0.50 diopters (D) or higher. Toric IOL calculations were made using TCA measurements. The eyes were grouped as either "with-the-rule" ( WTR) or "against-the-rule" (ATR) on the basis of the steep anterior corneal meridian. The post-operative refractive astigmatic prediction error was analyzed 1 month post-operatively using the vector analysis by the Alpins method and double-angle plots method. Results: The correction indexes were 1.14 +/- 0.29 in the ATR eyes and 1.25 +/- 0.18 for the WTR eyes, indicating a tendency toward over-correction. The mean over-correction was 0.22 +/- 0.52D in the ATR group and 0.65 +/- 0.60D in the WTR group. The magnitude of error (ME) values were significantly different from the ideal value of zero in both groups (ATR: P = 0.03; WTR: P = 0.00). No significant difference in mean absolute error (MAE) in predicted residual astigmatism was found between ATR and WTR groups (0.61 +/- 0.42 D versus 0.64 +/- 0.39 D; P = 0.54). The ATR group yielded better results, with 48% <0.50D prediction error in the main analysis. Conclusions: The results suggested that in cases of high PCA, the toric IOL calculation, which was performed using TCA, may cause a potential over-correction in the ATR and WTR eyes. For ATR eyes, over-correction led to slight disruption of post-operative visual quality because of the "with-the-rule" residual astigmatism after operation. Therefore, we suggested using TCA for toric IOL calculation in ATR eyes.
引用
收藏
页码:2967 / 2971
页数:5
相关论文
共 20 条
[1]   A NEW METHOD OF ANALYZING VECTORS FOR CHANGES IN ASTIGMATISM [J].
ALPINS, NA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (04) :524-533
[2]   The effect of posterior corneal flat meridian and astigmatism amount on the total corneal astigmatism estimated from anterior corneal measurements [J].
Eom, Youngsub ;
Kang, Su-Yeon ;
Kim, Hyo Myung ;
Song, Jong Suk .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (11) :1769-1777
[3]   Prevalence of corneal astigmatism before cataract surgery [J].
Ferrer-Blasco, Teresa ;
Montes-Mico, Robert ;
Peixoto-de-Matos, Sofia C. ;
Gonzalez-Meijome, Jose M. ;
Cervino, Alejandro .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) :70-75
[4]   Five-year refractive changes in an adult population - Reykjavik eye study [J].
Gudmundsdottir, E ;
Arnarsson, A ;
Jonasson, F .
OPHTHALMOLOGY, 2005, 112 (04) :672-677
[5]   With the rule astigmatism is not the rule in the elderly -: Reykjavik Eye Study:: A population based study of refraction and visual acuity in citizens of Reykjavik 50 years and older [J].
Gudmundsdottir, E ;
Jonasson, F ;
Jonsson, V ;
Stefánsson, E ;
Sasaki, H ;
Sasaki, K .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2000, 78 (06) :642-646
[6]   Effects of Aging on Anterior and Posterior Corneal Astigmatism [J].
Ho, Jau-Der ;
Liou, Shiow-Wen ;
Tsai, Ray Jui-Fang ;
Tsai, Ching-Yao .
CORNEA, 2010, 29 (06) :632-637
[7]   Accuracy of Corneal Astigmatism Estimation by Neglecting the Posterior Corneal Surface Measurement [J].
Ho, Jau-Der ;
Tsai, Ching-Yao ;
Liou, Shiow-Wen .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (05) :788-795
[8]   Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery A Systematic Review and Meta-analysis [J].
Kessel, Line ;
Andresen, Jens ;
Tendal, Britta ;
Erngaard, Ditte ;
Flesner, Per ;
Hjortdal, Jesper .
OPHTHALMOLOGY, 2016, 123 (02) :275-286
[9]   Contribution of posterior corneal astigmatism to total corneal astigmatism [J].
Koch, Douglas D. ;
Ali, Shazia F. ;
Weikert, Mitchell P. ;
Shirayama, Mariko ;
Jenkins, Richard ;
Wang, Li .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12) :2080-2087
[10]   Assessing the Likely Effect of Posterior Corneal Curvature on Toric IOL Calculation for IOLs of 2.50 D or Greater Cylinder Power [J].
LaHood, Benjamin R. ;
Goggin, Michael ;
Esterman, Adrian .
JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (11) :730-735