The AWaveECG: The differences to the normal 12-lead ECG amplitudes

被引:1
作者
Proniewska, Klaudia K. [1 ]
Abaecherli, Roger [2 ]
van Dam, Peter M. [3 ,4 ]
机构
[1] Jagiellonian Univ Med Coll, Krakow, Poland
[2] Lucerne Univ Appl Sci & Arts, HSLU, Luzern, Switzerland
[3] Univ Med Ctr Utrecht, Dept Cardiol, Utrecht, Netherlands
[4] AGH Univ Sci & Technol, Dept Automat & Robot, Krakow, Poland
关键词
Normal ECG; AWaveECG; ECG amplitude distribution; NORMAL LIMITS; ELECTROCARDIOGRAM;
D O I
10.1016/j.jelectrocard.2022.10.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The QRS, ST segment, and T-wave waveforms of electrocardiogram are difficult to interpret, especially for non-ECG experts readers, like general practitioners. As the ECG waveforms are influenced by many factors, like body build, age, sex, electrode placement, even for experience ECG readers the waveform is difficult to interpret. In this research we have created a novel method to distinguish normal from abnormal ECG waveforms for an individual ECG based on the ECG amplitude distribution derived from normal standard 12-lead ECG recordings. Aim: Creation of a normal ECG amplitude distribution to enable the distinction by non-ECG experts of normal from abnormal waveforms of the standard 12-lead ECG. Methods: The ECGs of healthy normal controls in the PTB-XL database were used to construct a normal amplitude distribution of the 12 lead ECG for males and females. All ECGs were resampled to have the same number of samples to enable the classification of an individual ECG as either normal or abnormal, i.e. within the normal amplitude distribution or outside, the AWaveECG. Results: From the same PTB-XL database six ECG's were selected, normal, left and right bundle branch block, and three with a myocardial infarction. The normal ECG was obviously within the normal distribution, and all other five showed clear abnormal ECG amplitudes outside the normal distribution in any of the ECG segments (QRS, ST segment and remaining STT segment). Conclusion: The AWaveECG can distinguish the abnormal from normal ECG waveform segments, making the ECG easier to classify as normal or abnormal. Conduction disorders and ST changes due to ischemia and abnormal Twaves are effortless to detect, also by non-ECG expert readers, thus improving the early detection of cardiac patients.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 50 条
  • [31] All-ECG: A Least-number of Leads ECG Monitor for Standard 12-lead ECG Tracking during Motion
    Zhang, Qingxue
    Frick, Kyle
    2019 IEEE HEALTHCARE INNOVATIONS AND POINT OF CARE TECHNOLOGIES (HI-POCT), 2019, : 103 - 106
  • [32] 12-LEAD AND CONTINUOUS ECG RECORDINGS OF SUBJECTS DURING INPATIENT ADMINISTRATION OF SMOKED COCAINE
    PENTEL, PR
    THOMPSON, T
    HATSUKAMI, DK
    SALERNO, DM
    DRUG AND ALCOHOL DEPENDENCE, 1994, 35 (02) : 107 - 116
  • [33] Data Fusion of Multivariate Time Series: Application to Noisy 12-Lead ECG Signals
    Diao, Chen
    Wang, Bin
    Cai, Ning
    APPLIED SCIENCES-BASEL, 2019, 9 (01):
  • [34] Digital Phenotyping of Myocardial Dysfunction With 12-Lead ECG Tiptoeing Into the Future With Machine Learning
    Nasir, Khurram
    Khera, Rohan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (08) : 942 - 944
  • [35] Detection of culprit coronary lesion location in pre-hospital 12-lead ECG
    Gregg, Richard E.
    Babaeizadeh, Saeed
    JOURNAL OF ELECTROCARDIOLOGY, 2014, 47 (06) : 890 - 894
  • [36] Atrial Electrical Activity Detection Using Linear Combination of 12-Lead ECG Signals
    Perlman, Or
    Katz, Amos
    Weissman, Noam
    Amit, Guy
    Zigel, Yaniv
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (04) : 1034 - 1043
  • [37] How to use the 12-lead ECG to predict the site of origin of idiopathic ventricular arrhythmias
    Enriquez, Andres
    Baranchuk, Adrian
    Briceno, David
    Saenz, Luis
    Garcia, Fermin
    HEART RHYTHM, 2019, 16 (10) : 1538 - 1544
  • [38] A new approach to confirming or excluding ventricular pre-excitation on a 12-lead ECG
    Eisenberger, Martin
    Davidson, Neil Colin
    Todd, Derick Michael
    Garratt, Clifford John
    Fitzpatrick, Adam Paul
    EUROPACE, 2010, 12 (01): : 119 - 123
  • [39] Accurate and reliable 3-lead to 12-lead ECG reconstruction methodology for remote health monitoring applications
    Maheshwari, S.
    Acharyya, A.
    Rajalakshmi, P.
    Puddu, P. E.
    Schiariti, M.
    IRBM, 2014, 35 (06) : 341 - 350
  • [40] Estimation performance of a reduced lead system during continuous 12-lead ECG ST-segment monitoring
    Guldenring, Daniel
    Finlay, Dewar D.
    Nelwan, Stefan P.
    Nugent, Chris D.
    Donnelly, Mark P.
    Bond, Raymond R.
    JOURNAL OF ELECTROCARDIOLOGY, 2012, 45 (06) : 604 - 608