Dosimetric verification of four dose calculation algorithms for spine stereotactic body radiotherapy

被引:4
作者
Hirashima, Hideaki [1 ]
Nakamura, Mitsuhiro [1 ,2 ]
Nakamura, Kiyonao [1 ]
Matsuo, Yukinori [1 ]
Mizowaki, Takashi [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Radiat Oncol & Image Appl Therapy, 54 Kawahara Cho,Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Adv Med Phys, 53 Kawahara Cho,Sakyo Ku, Kyoto 6068507, Japan
关键词
dosimetric verification; dose calculation algorithm; spine SBRT; HIGH-Z INHOMOGENEITY; RADIATION-THERAPY; MONTE-CARLO; HIP-PROSTHESIS; ACUROS XB; METASTASES; PROBABILITY; MULTICENTER; CONSENSUS;
D O I
10.1093/jrr/rrad086
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The applications of Type B [anisotropic analytical algorithm (AAA) and collapsed cone (CC)] and Type C [Acuros XB (AXB) and photon Monte Carlo (PMC)] dose calculation algorithms in spine stereotactic body radiotherapy (SBRT) were evaluated. Water- and bone-equivalent phantoms were combined to evaluate the percentage depth dose and dose profile. Subsequently, 48 consecutive patients with clinical spine SBRT plans were evaluated. All treatment plans were created using AXB in Eclipse. The prescription dose was 24 Gy in two fractions at a 10 MV FFF on TrueBeam. The doses were then recalculated with AAA, CC and PMC while maintaining the AXB-calculated monitor units and beam arrangement. The dose index values obtained using the four dose calculation algorithms were then compared. The AXB and PMC dose distributions agreed with the bone-equivalent phantom measurements (within +/- 2.0%); the AAA and CC values were higher than those in the bone-equivalent phantom region. For the spine SBRT plans, PMC, AAA and CC were overestimated compared with AXB in terms of the near minimum and maximum doses of the target and organ at risk, respectively; the mean dose difference was within 4.2%, which is equivalent with within 1 Gy. The phantom study showed that the results from AXB and PMC agreed with the measurements within +/- 2.0%. However, the mean dose difference ranged from 0.5 to 1 Gy in the spine SBRT planning study when the dose calculation algorithms changed. Users should incorporate a clinical introduction that includes an awareness of these differences.
引用
收藏
页码:109 / 118
页数:10
相关论文
共 33 条
[1]   Monte Carlo-based correction factors for ion chamber dosimetry in heterogeneous phantoms for megavoltage photon beams [J].
Araki, Fujio .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22) :7615-7627
[2]   Stereotactic body radiation therapy: The report of AAPM Task Group 101 [J].
Benedict, Stanley H. ;
Yenice, Kamil M. ;
Followill, David ;
Galvin, James M. ;
Hinson, William ;
Kavanagh, Brian ;
Keall, Paul ;
Lovelock, Michael ;
Meeks, Sanford ;
Papiez, Lech ;
Purdie, Thomas ;
Sadagopan, Ramaswamy ;
Schell, Michael C. ;
Salter, Bill ;
Schlesinger, David J. ;
Shiu, Almon S. ;
Solberg, Timothy ;
Song, Danny Y. ;
Stieber, Volker ;
Timmerman, Robert ;
Tome, Wolfgang A. ;
Verellen, Dirk ;
Wang, Lu ;
Yin, Fang-Fang .
MEDICAL PHYSICS, 2010, 37 (08) :4078-4101
[3]  
Biggs S., 2022, J OPEN SOURCE SOFTW, V7, P4555
[4]   Outcomes for Spine Stereotactic Body Radiation Therapy and an Analysis of Predictors of Local Recurrence [J].
Bishop, Andrew J. ;
Tao, Randa ;
Rebueno, Neal C. ;
Christensen, Eva N. ;
Allen, Pamela K. ;
Wang, Xin A. ;
Amini, Behrang ;
Tannir, Nizar M. ;
Tatsui, Claudio E. ;
Rhines, Laurence D. ;
Li, Jing ;
Chang, Eric L. ;
Brown, Paul D. ;
Ghia, Amol J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 92 (05) :1016-1026
[5]   Normal tissue complication probability of vertebral compression fracture after stereotactic body radiotherapy for de novo spine metastasis [J].
Chen, Xuguang ;
Gui, Chengcheng ;
Grimm, Jimm ;
Huang, Ellen ;
Kleinberg, Lawrence ;
Lo, Larry ;
Sciubba, Daniel ;
Khan, Majid ;
Redmond, Kristin J. .
RADIOTHERAPY AND ONCOLOGY, 2020, 150 :142-149
[6]   International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic Radiosurgery [J].
Cox, Brett W. ;
Spratt, Daniel E. ;
Lovelock, Michael ;
Bilsky, Mark H. ;
Lis, Eric ;
Ryu, Samuel ;
Sheehan, Jason ;
Gerszten, Peter C. ;
Chang, Eric ;
Gibbs, Iris ;
Soltys, Scott ;
Sahgal, Arjun ;
Deasy, Joe ;
Flickinger, John ;
Quader, Mubina ;
Mindea, Stefan ;
Yamada, Yoshiya .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (05) :E597-E605
[7]   VALIDITY OF TRANSITION-ZONE DOSIMETRY AT HIGH ATOMIC-NUMBER INTERFACES IN MEGAVOLTAGE PHOTON BEAMS [J].
DAS, IJ ;
KASE, KR ;
MEIGOONI, AS ;
KHAN, FM ;
WERNER, BL .
MEDICAL PHYSICS, 1990, 17 (01) :10-16
[8]   UK 2022 Consensus on Normal Tissue Dose-Volume Constraints for Oligometastatic, Primary Lung and Hepatocellular Carcinoma Stereotactic Ablative Radiotherapy [J].
Diez, P. ;
Hanna, G. G. ;
Aitken, K. L. ;
van As, N. ;
Carver, A. ;
Colaco, R. J. ;
Conibear, J. ;
Dunne, E. M. ;
Eaton, D. J. ;
Franks, K. N. ;
Good, J. S. ;
Harrow, S. ;
Hatfield, P. ;
Hawkins, M. A. ;
Jain, S. ;
McDonald, F. ;
Patel, R. ;
Rackley, T. ;
Sanghera, P. ;
Tree, A. ;
Murray, L. .
CLINICAL ONCOLOGY, 2022, 34 (05) :288-300
[9]   Maintaining dosimetric quality when switching to a Monte Carlo dose engine for head and neck volumetric-modulated arc therapy planning [J].
Feygelman, Vladimir ;
Latifi, Kujtim ;
Bowers, Mark ;
Greco, Kevin ;
Moros, Eduardo G. ;
Isacson, Max ;
Angerud, Agnes ;
Caudell, Jimmy .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (05)
[10]   Estimated Risk Level of Unified Stereotactic Body Radiation Therapy Dose Tolerance Limits for Spinal Cord [J].
Grimm, Jimm ;
Sahgal, Arjun ;
Soltys, Scott G. ;
Luxton, Gary ;
Patel, Ashish ;
Herbert, Scott ;
Xue, Jinyu ;
Ma, Lijun ;
Yorke, Ellen ;
Adler, John R. ;
Gibbs, Iris C. .
SEMINARS IN RADIATION ONCOLOGY, 2016, 26 (02) :165-171