Insight into contact force local impedance technology for predicting effective pulmonary vein isolation

被引:7
作者
Lepillier, Antoine [1 ]
Maggio, Ruggero [2 ]
De Sanctis, Valerio [3 ]
Malacrida, Maurizio [4 ]
Stabile, Giuseppe [5 ]
Zakine, Cyril [6 ]
Champ-Rigot, Laure [7 ]
Anselmino, Matteo [8 ]
Segreti, Luca [9 ]
Dell'Era, Gabriele [10 ]
Garnier, Fabien [11 ]
Mascia, Giuseppe [12 ]
Pandozi, Claudio [13 ]
Dello Russo, Antonio [14 ]
Scaglione, Marco [15 ]
Cosaro, Giuseppe [4 ]
Ferraro, Anna [2 ]
Paziaud, Olivier [1 ]
Maglia, Giampiero [16 ]
Solimene, Francesco [17 ]
机构
[1] Ctr Cardiol Nord, St Denis, France
[2] Infermi Hosp, Rivoli, Italy
[3] IRCCS Osped Galeazzi St Ambrogio, Milan, Italy
[4] Boston Sci, Milan, Italy
[5] Mediterranea Cardioctr, Naples, Italy
[6] Clin NCT, St Cyr Sur Loire, France
[7] Normandie Univ, UNICAEN, CHU Caen Normandie, Caen, France
[8] Univ Turin, Citta Salute & Sci Torino Hosp, Dept Med Sci, Div Cardiol, Turin, Italy
[9] Azienda Osp Univ Pisana, New St Chiara Hosp, Cardiac Thorac Vasc Dept, Div Cardiol 2, Pisa, Italy
[10] Azienda Osped Univ Maggiore Car, Novara, Italy
[11] Ctr Hosp Dijon Bourgogne, Dijon, France
[12] IRCCS San Martino Polyclin Hosp, Genoa, Italy
[13] San Filippo Neri Hosp, Rome, Italy
[14] Marche Polytech Univ, Cardiol & Arrhythmol Clin, Ancona, Italy
[15] Cardinal Massaia Hosp, Asti, Italy
[16] Azienda Osped Pugliese Ciaccio, Catanzaro, Italy
[17] Clin Montevergine, Dept Cardiac Electrophysiol & Arrhythmol, Mercogliano, Italy
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2023年 / 10卷
关键词
atrial fibrillation; catheter ablation; local impedance; contact force; lesion formation; pulmonary vein isolation; RADIOFREQUENCY CATHETER ABLATION;
D O I
10.3389/fcvm.2023.1169037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have the potential to act as a reliable predictor of the durability of the lesions created. Objective: We aimed to collect data on the procedural parameters affecting LI-guided ablation in a large multicenter registry. Methods: A total of 212 consecutive patients enrolled in the CHARISMA registry and undergoing their first pulmonary vein (PV) isolation for paroxysmal and persistent AF were included. Results: In all, 13,891 radiofrequency (RF) applications of >= 3 s duration were assessed. The first-pass PV isolation rate was 93.3%. A total of 80 PV gaps were detected. At successful ablation spots, baseline LI and absolute LI drop were larger than at PV gap spots (161.4 +/- 19 O vs. 153.0 +/- 13 Omega, p < 0.0001 for baseline LI; 22.1 +/- 9 Omega vs. 14.4 +/- 5 Omega, p < 0.0001 for LI drop). On the basis of Receiver operating characteristic curve analysis, the ideal LI drop, which predicted successful ablation, was >21 Omega at anterior sites and >18 Omega at posterior sites. There was a non-linear association between the magnitude of LI drop and contact-force (CF) (r= 0.14, 95% CI: 0.13-0.16, p < 0.0001) whereas both CF and LI drop were inversely related with delivery time (DT) (-0.22, -0.23 to -0.20, p < 0.0001 for CF; -0.27, -0.29 to -0.26, p < 0.0001 for LI drop). Conclusion: An LI drop >21 Omega at anterior sites and >18 Omega at posterior sites predicts successful ablation. A higher CF was associated with an increased likelihood of ideal LI drop. The combination of good CF and adequate LI drop allows a significant reduction in RF DT.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Requirement of larger local impedance reduction for successful lesion formation at carinal area during pulmonary vein isolation
    Ikenouchi, Takashi
    Takigawa, Masateru
    Goya, Masahiko
    Martin, Claire A.
    Takahashi, Yoshihide
    Shimizu, Yuki
    Amemiya, Miki
    Kamata, Tatsuaki
    Nishimura, Takuro
    Tao, Susumu
    Miyazaki, Shinsuke
    Sasano, Tetsuo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 65 (02) : 509 - 518
  • [42] Reduced residual conduction gaps and favourable outcome in contact force-guided circumferential pulmonary vein isolation
    Itoh, Taihei
    Kimura, Masaomi
    Tomita, Hirofumi
    Sasaki, Shingo
    Owada, Shingen
    Horiuchi, Daisuke
    Sasaki, Kenichi
    Ishida, Yuji
    Kinjo, Takahiko
    Okumura, Ken
    EUROPACE, 2016, 18 (04): : 531 - 537
  • [43] General anesthesia improves contact force and reduces gap formation in pulmonary vein isolation: a comparison with conscious sedation
    Akio Chikata
    Takeshi Kato
    Takanori Yaegashi
    Satoru Sakagami
    Chieko Kato
    Takahiro Saeki
    Keiichi Kawai
    Shin-ichiro Takashima
    Hisayoshi Murai
    Soichiro Usui
    Hiroshi Furusho
    Shuichi Kaneko
    Masayuki Takamura
    Heart and Vessels, 2017, 32 : 997 - 1005
  • [44] Arrhythmia-free survival and pulmonary vein reconnection patterns after second-generation cryoballoon and contact-force radiofrequency pulmonary vein isolation
    Buist, Thomas J.
    Adiyaman, Ahmet
    Smit, Jaap Jan J.
    Misier, Anand R. Ramdat
    Elvan, Arif
    CLINICAL RESEARCH IN CARDIOLOGY, 2018, 107 (06) : 498 - 506
  • [45] Evaluation and comparison of impedance and amplitude changes in lesion index-guided pulmonary vein isolation
    Kaneko, Yutaro
    Naruse, Yoshihisa
    Narumi, Taro
    Sano, Makoto
    Urushida, Tsuyoshi
    Maekawa, Yuichiro
    JOURNAL OF ARRHYTHMIA, 2024, 40 (01) : 100 - 108
  • [46] Comparison of lesion formation between contact force-guided and non-guided circumferential pulmonary vein isolation: A prospective, randomized study
    Kimura, Masaomi
    Sasaki, Shingo
    Owada, Shingen
    Horiuchi, Daisuke
    Sasaki, Kenichi
    Itoh, Taihei
    Ishida, Yuji
    Kinjo, Takahiko
    Tomita, Hirofumi
    Okumura, Ken
    HEART RHYTHM, 2014, 11 (06) : 984 - 991
  • [47] Real-Time Contact Force Sensing for Pulmonary Vein Isolation in the Setting of Paroxysmal Atrial Fibrillation: Procedural and 1-Year Results
    Marijon, Eloi
    Fazaa, Samia
    Narayanan, Kumar
    Guy-Moyat, Benoit
    Bouzeman, Abdeslam
    Providencia, Rui
    Treguer, Frederic
    Combes, Nicolas
    Bortone, Agustin
    Boveda, Serge
    Combes, Stephane
    Albenque, Jean-paul
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (02) : 130 - 137
  • [48] The incidence and location of epicardial connections in the era of contact force guided ablation for pulmonary vein isolation
    Sun, Xuerong
    Niu, Guodong
    Lin, Jinxuan
    Suo, Ni
    Guo, Tao
    Lu, Jiang
    Feng, Tianjie
    Zheng, Lihui
    Yao, Yan
    Zhang, Shu
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (09) : 2381 - 2390
  • [49] Comparison of contact force-guided procedure with non-contact force-guided procedure during left atrial mapping and pulmonary vein isolation: impact of contact force on recurrence of atrial fibrillation
    Hisaki Makimoto
    Christian-H Heeger
    Tina Lin
    Andreas Rillig
    Andreas Metzner
    Erik Wissner
    Shibu Mathew
    Sebastian Deiss
    Peter Rausch
    Christine Lemeš
    Karl-Heinz Kuck
    Feifan Ouyang
    Roland Richard Tilz
    Clinical Research in Cardiology, 2015, 104 : 861 - 870
  • [50] Prospective Characterization of Catheter-Tissue Contact Force at Different Anatomic Sites During Antral Pulmonary Vein Isolation
    Kumar, Saurabh
    Morton, Joseph B.
    Lee, Justin
    Halloran, Karen
    Spence, Steven J.
    Gorelik, Alexandra
    Hepworth, Graham
    Kistler, Peter M.
    Kalman, Jonathan M.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (06) : 1124 - 1129