Insight into contact force local impedance technology for predicting effective pulmonary vein isolation

被引:7
作者
Lepillier, Antoine [1 ]
Maggio, Ruggero [2 ]
De Sanctis, Valerio [3 ]
Malacrida, Maurizio [4 ]
Stabile, Giuseppe [5 ]
Zakine, Cyril [6 ]
Champ-Rigot, Laure [7 ]
Anselmino, Matteo [8 ]
Segreti, Luca [9 ]
Dell'Era, Gabriele [10 ]
Garnier, Fabien [11 ]
Mascia, Giuseppe [12 ]
Pandozi, Claudio [13 ]
Dello Russo, Antonio [14 ]
Scaglione, Marco [15 ]
Cosaro, Giuseppe [4 ]
Ferraro, Anna [2 ]
Paziaud, Olivier [1 ]
Maglia, Giampiero [16 ]
Solimene, Francesco [17 ]
机构
[1] Ctr Cardiol Nord, St Denis, France
[2] Infermi Hosp, Rivoli, Italy
[3] IRCCS Osped Galeazzi St Ambrogio, Milan, Italy
[4] Boston Sci, Milan, Italy
[5] Mediterranea Cardioctr, Naples, Italy
[6] Clin NCT, St Cyr Sur Loire, France
[7] Normandie Univ, UNICAEN, CHU Caen Normandie, Caen, France
[8] Univ Turin, Citta Salute & Sci Torino Hosp, Dept Med Sci, Div Cardiol, Turin, Italy
[9] Azienda Osp Univ Pisana, New St Chiara Hosp, Cardiac Thorac Vasc Dept, Div Cardiol 2, Pisa, Italy
[10] Azienda Osped Univ Maggiore Car, Novara, Italy
[11] Ctr Hosp Dijon Bourgogne, Dijon, France
[12] IRCCS San Martino Polyclin Hosp, Genoa, Italy
[13] San Filippo Neri Hosp, Rome, Italy
[14] Marche Polytech Univ, Cardiol & Arrhythmol Clin, Ancona, Italy
[15] Cardinal Massaia Hosp, Asti, Italy
[16] Azienda Osped Pugliese Ciaccio, Catanzaro, Italy
[17] Clin Montevergine, Dept Cardiac Electrophysiol & Arrhythmol, Mercogliano, Italy
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2023年 / 10卷
关键词
atrial fibrillation; catheter ablation; local impedance; contact force; lesion formation; pulmonary vein isolation; RADIOFREQUENCY CATHETER ABLATION;
D O I
10.3389/fcvm.2023.1169037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have the potential to act as a reliable predictor of the durability of the lesions created. Objective: We aimed to collect data on the procedural parameters affecting LI-guided ablation in a large multicenter registry. Methods: A total of 212 consecutive patients enrolled in the CHARISMA registry and undergoing their first pulmonary vein (PV) isolation for paroxysmal and persistent AF were included. Results: In all, 13,891 radiofrequency (RF) applications of >= 3 s duration were assessed. The first-pass PV isolation rate was 93.3%. A total of 80 PV gaps were detected. At successful ablation spots, baseline LI and absolute LI drop were larger than at PV gap spots (161.4 +/- 19 O vs. 153.0 +/- 13 Omega, p < 0.0001 for baseline LI; 22.1 +/- 9 Omega vs. 14.4 +/- 5 Omega, p < 0.0001 for LI drop). On the basis of Receiver operating characteristic curve analysis, the ideal LI drop, which predicted successful ablation, was >21 Omega at anterior sites and >18 Omega at posterior sites. There was a non-linear association between the magnitude of LI drop and contact-force (CF) (r= 0.14, 95% CI: 0.13-0.16, p < 0.0001) whereas both CF and LI drop were inversely related with delivery time (DT) (-0.22, -0.23 to -0.20, p < 0.0001 for CF; -0.27, -0.29 to -0.26, p < 0.0001 for LI drop). Conclusion: An LI drop >21 Omega at anterior sites and >18 Omega at posterior sites predicts successful ablation. A higher CF was associated with an increased likelihood of ideal LI drop. The combination of good CF and adequate LI drop allows a significant reduction in RF DT.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Comparing cryoballoon and contact-force guided radiofrequency ablation in pulmonary vein isolation for atrial fibrillation in patients with hypertrophic cardiomyopathy
    Kinjo, Takahiko
    Kimura, Masaomi
    Horiuchi, Daisuke
    Itoh, Taihei
    Ishida, Yuji
    Nishizaki, Kimitaka
    Toyama, Yuichi
    Hamaura, Shogo
    Sasaki, Shingo
    Tomita, Hirofumi
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (07) : 1635 - 1645
  • [32] Lesion effects in terms of local impedance variations after pulsed-field ablation during pulmonary vein isolation: a case report
    Iacopino, Saverio
    Fabiano, Gennaro
    Malacrida, Maurizio
    Petretta, Andrea
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2023, 7 (05)
  • [33] Lower contact force predicts right pulmonary vein carina breakthrough after ablation index-guided pulmonary vein isolation using high-power short-duration
    Chen, Wei-Tso
    Chung, Fa-Po
    Lin, Yenn-Jiang
    Chang, Shih-Lin
    Lo, Li-Wei
    Hu, Yu-Feng
    Tuan, Ta-Chuan
    Chao, Tze-Fan
    Liao, Jo-Nan
    Lin, Chin-Yu
    Chang, Ting-Yung
    Kuo, Ling
    Wu, Cheng-, I
    Liu, Chih-Min
    Liu, Shin-Huei
    Hsieh, Yu-Cheng
    Li, Cheng-Hung
    Chen, Shih-Ann
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (01) : 60 - 68
  • [34] Superior efficacy of pulmonary vein isolation with online contact force measurement persists after the learning period: a prospective case control study
    Michael Wolf
    Johan B. Saenen
    Wim Bories
    Hielko P. Miljoen
    Sara Nullens
    Christiaan J. Vrints
    Andrea Sarkozy
    Journal of Interventional Cardiac Electrophysiology, 2015, 43 : 287 - 296
  • [35] Electrical Reconnection After Pulmonary Vein Isolation Is Contingent on Contact Force During Initial Treatment Results From the EFFICAS I Study
    Neuzil, Petr
    Reddy, Vivek Y.
    Kautzner, Josef
    Petru, Jan
    Wichterle, Dan
    Shah, Dipen
    Lambert, Hendrik
    Yulzari, Aude
    Wissner, Erik
    Kuck, Karl-Heinz
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (02) : 327 - 333
  • [36] Contact force facilitates the achievement of an unexcitable ablation line during pulmonary vein isolation
    Benjamin Schaeffer
    Stephan Willems
    Christian Meyer
    Jakob Lüker
    Ruken Ö. Akbulak
    Julia Moser
    Mario Jularic
    Christian Eickholt
    Jana M. Schwarzl
    Melanie Gunawardene
    Pawel Kuklik
    Arian Sultan
    Boris A. Hoffmann
    Daniel Steven
    Clinical Research in Cardiology, 2018, 107 : 632 - 641
  • [37] Requirement of larger local impedance reduction for successful lesion formation at carinal area during pulmonary vein isolation
    Ikenouchi, Takashi
    Takigawa, Masateru
    Goya, Masahiko
    Martin, Claire A.
    Takahashi, Yoshihide
    Shimizu, Yuki
    Amemiya, Miki
    Kamata, Tatsuaki
    Nishimura, Takuro
    Tao, Susumu
    Miyazaki, Shinsuke
    Sasano, Tetsuo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 65 (02) : 509 - 518
  • [38] Combined local impedance and contact force for radiofrequency ablation assessment
    Garrott, Kara
    Laughner, Jacob
    Gutbrod, Sarah
    Sugrue, Alan
    Shuros, Allan
    Sulkin, Matt
    Yasin, Omar
    Bush, Jamie
    Pottinger, Nathan
    Meyers, Jason
    Kapa, Suraj
    HEART RHYTHM, 2020, 17 (08) : 1371 - 1380
  • [39] Requirement of larger local impedance reduction for successful lesion formation at carinal area during pulmonary vein isolation
    Takashi Ikenouchi
    Masateru Takigawa
    Masahiko Goya
    Claire A. Martin
    Yoshihide Takahashi
    Yuki Shimizu
    Miki Amemiya
    Tatsuaki Kamata
    Takuro Nishimura
    Susumu Tao
    Shinsuke Miyazaki
    Tetsuo Sasano
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 509 - 518
  • [40] General anesthesia improves contact force and reduces gap formation in pulmonary vein isolation: a comparison with conscious sedation
    Akio Chikata
    Takeshi Kato
    Takanori Yaegashi
    Satoru Sakagami
    Chieko Kato
    Takahiro Saeki
    Keiichi Kawai
    Shin-ichiro Takashima
    Hisayoshi Murai
    Soichiro Usui
    Hiroshi Furusho
    Shuichi Kaneko
    Masayuki Takamura
    Heart and Vessels, 2017, 32 : 997 - 1005