Achieving Precise Cup Positioning in Direct Anterior Total Hip Arthroplasty: A Narrative Review

被引:11
作者
Streck, Laura Elisa [1 ]
Boettner, Friedrich [1 ]
机构
[1] Hosp Special Surg, 535 East 70th St, New York, NY 10021 USA
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 02期
关键词
hip replacement; safe zone; component positioning; fluoroscopy; navigation; imaging; ACETABULAR COMPONENT POSITION; RADIATION-EXPOSURE; RISK-FACTORS; PELVIC TILT; PLACEMENT; REPLACEMENT; ORIENTATION; DISLOCATION; ANTEVERSION; NAVIGATION;
D O I
10.3390/medicina59020271
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Malpositioned implants in total hip arthroplasty are associated with impingement, increased wear, and dislocations, thus precise cup positioning is crucial. However, significant deviations between targeted and actually achieved cup positions have been found even in patients operated by experienced surgeons. When aiming for higher accuracy, various methods based on freehand positioning lead by anatomic landmarks, C-arm fluoroscopy, imageless navigation, or robotic-assisted-surgery have been described. There is a constant development of new products aiming to simplify and improve intraoperative guidance. Both the literature and expert opinions on this topic are often quite controversial. This article aims to give an overview of the different methods and systems with their specific advantages and potential pitfalls while also taking a look into the future of cup positioning in anterior hip replacements.
引用
收藏
页数:14
相关论文
共 97 条
[1]   ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT [J].
ACKLAND, MK ;
BOURNE, WB ;
UHTHOFF, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :409-413
[2]   The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement - A preliminary study of 1000 cases investigating postoperative stability [J].
Archbold, H. A. P. ;
Mockford, B. ;
Molloy, D. ;
McConway, J. ;
Ogonda, L. ;
Beverland, D. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07) :883-886
[3]  
Arulampalam Jevan, 2022, Surg Technol Int, V41, P381, DOI 10.52198/22.STI.41.OS1615
[4]   Accuracy of Acetabular Component Position in Hip Arthroplasty [J].
Barrack, Robert L. ;
Krempec, Jeffrey A. ;
Clohisy, John C. ;
McDonald, Douglas J. ;
Ricci, William M. ;
Ruh, Erin L. ;
Nunley, Ryan M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (19) :1760-1768
[5]   Can a simple iPad app improve C-arm based component position in anterior THA? [J].
Bechler, Ulrich ;
Springer, Bernhard ;
Rueckl, Kilian ;
Rolvien, Tim ;
Boettner, Friedrich .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (08) :1401-1409
[6]   Placement of the acetabular component [J].
Beverland, D. E. ;
O'Neill, C. K. J. ;
Rutherford, M. ;
Molloy, D. ;
Hill, J. C. .
BONE & JOINT JOURNAL, 2016, 98B (01) :37-43
[7]  
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[8]   The Accuracy of Acetabular Component Position Using a Novel Method to Determine Anteversion [J].
Boettner, Friedrich ;
Zingg, Matthieu ;
Emara, Ahmed K. ;
Waldstein, Wenzel ;
Faschingbauer, Martin ;
Kasparek, Maximilian F. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (04) :1180-1185
[9]   Historical overview of hip arthroplasty: From humble beginnings to a high-tech future [J].
Bota, Nicolae Ciprian ;
Nistor, Dan-Viorel ;
Caterev, Sergiu ;
Todor, Adrian .
ORTHOPEDIC REVIEWS, 2021, 13 (01)
[10]   The Epidemiology of Revision Total Hip Arthroplasty in the United States [J].
Bozic, Kevin J. ;
Kurtz, Steven M. ;
Lau, Edmund ;
Ong, Kevin ;
Vail, Thomas P. ;
Berry, Daniel J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01) :128-133