Vortex-induced vibration performance and mechanism of long-span railway bridge streamlined box girder

被引:2
|
作者
Duan, Qingsong [1 ,5 ]
Ma, Cunming [2 ,3 ,6 ]
Li, Qiusheng [4 ]
机构
[1] Southwest Univ Sci & Technol, Sch Civil Engn & Architecture, Mianyang, Peoples R China
[2] Southwest Jiaotong Univ, Dept Bridge Engn, Chengdu, Peoples R China
[3] SouthwestJiaotong Univ, Wind Engn Key Lab Sichuan Prov, Chengdu, Peoples R China
[4] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Peoples R China
[5] Southwest Univ Sci & Technol, Sch Civil Engn & Architecture, 59, Qinglong Rd, Mianyang 621010, Peoples R China
[6] Southwest Jiaotong Univ, Dept Bridge Engn, 111, 2nd Ring Rd, Chengdu 610031, Peoples R China
基金
中国博士后科学基金;
关键词
narrow streamlined box girder; aspect ratio between width and height; railing base; vortex-induced vibration; sectional model; wind tunnel testing; virtual model wind tunnel testing; MODEL; FLOW;
D O I
10.1177/13694332231190708
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To investigate the vortex-induced vibration (VIV) characteristics of a narrow-streamlined railway box girder and optimize its VIV performance, a long-span railway cable-stayed bridge was analyzed. Based on sectional model wind tunnel tests, the influence of the wind attack angle and the damping ratio on the VIV performance of the girder was investigated. The main inducing factors of the VIV of the narrow railway box girder were explored and a series of corresponding optimization schemes was put forward. The results show that there is no VIV when the wind attack angles are -5 & DEG;, -3 & DEG; and 0 & DEG;, and the damping ratio is 0.2%. The non-dimensional maximum amplitudes 1000y/D of the girder at wind attack angles of +3 & DEG; and +5 & DEG; are 14.4 and 19.4, respectively. The maximum amplitudes decrease with the increase of the damping ratios. The railing base is the influence factor that induces the vertical VIV, because the separation vortices between the railing base and ballast wall, as well as behind the railings, cause the VIV of the railway steel box girder. Compared with that of the girder section with the ballastless track board, the non-dimensional maximum vertical VIV amplitude of the girder without the ballastless track board greatly increases from 19.4 to 63.5, which could effectively suppress the VIV of the main girder. Lastly, in the construction state, vertical VIV occurs for girder sections I and II, which have respective aspect ratios of 4.3 and 4.6, at wind attack angles of +3 & DEG; and +5 & DEG;. Girder section III, which has a 6.7 aspect ratio and is more streamlined, does not have a VIV. The greater the aspect ratio of the bridge girder, the better the VIV performance. The relevant results could serve as a guide for wind resistance design of railway streamlined box girders.
引用
收藏
页码:2506 / 2519
页数:14
相关论文
共 50 条
  • [1] Calculation of spanwise vortex-induced vibration responses of long-span bridge girder
    Research Center of Wind Eng., Southwest Jiaotong University, Chengdu 610031, China
    Xinan Jiaotong Daxue Xuebao, 2008, 6 (740-746): : 740 - 746
  • [2] Vortex-induced vibration characteristics of twin-box girder section in long-span bridge: A numerical evaluation method
    Duan, Qingsong
    Shang, Jingmiao
    Ma, Cunming
    Li, Zhiguo
    PHYSICS OF FLUIDS, 2025, 37 (01)
  • [3] Mitigation effect of guide vanes on the vortex-induced vibration of a long-span closed-box girder suspension bridge
    Li, Ming
    Yang, Xiongwei
    Zhang, Haicheng
    Zhang, Hao
    Zhang, Tianyi
    Li, Mingshui
    JOURNAL OF VIBRATION AND CONTROL, 2024,
  • [4] Vortex-induced vibration analysis of a long-span arch bridge
    Tang, Chunping
    Zhang, Liangliang
    International Journal of Applied Mathematics and Statistics, 2013, 49 (19): : 324 - 332
  • [5] Study on The vortex-induced vibration of a long-span arch bridge
    Tang, Chunping
    Zhang, Liangliang
    MATERIALS SCIENCE, CIVIL ENGINEERING AND ARCHITECTURE SCIENCE, MECHANICAL ENGINEERING AND MANUFACTURING TECHNOLOGY, PTS 1 AND 2, 2014, 488-489 : 681 - +
  • [6] Case study of vortex-induced vibration and mitigation mechanism for a long-span suspension bridge
    Ge, Yaojun
    Zhao, Lin
    Cao, Jinxin
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2022, 220
  • [7] Control of Vortex-Induced Vibration of a Long-Span Bridge by Inclined Railings
    Xin, Dabo
    Zhan, Jian
    Zhang, Hongfu
    Ou, Jinping
    JOURNAL OF BRIDGE ENGINEERING, 2021, 26 (12)
  • [8] Reliability Evaluation of Vortex-Induced Vibration for a Long-Span Arch Bridge
    Li, Lingyao
    Wu, Teng
    He, Xuhui
    Hao, Jianming
    Wang, Hanfeng
    Xu, Hanyong
    JOURNAL OF BRIDGE ENGINEERING, 2018, 23 (05)
  • [9] Vortex-Induced Vibration Performance and Suppression Mechanism for a Long Suspension Bridge with Wide Twin-Box Girder
    Ma, C. M.
    Wang, J. X.
    Li, Q. S.
    Qin, H.
    Liao, H. L.
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (11)
  • [10] Aerodynamic Force Distribution Characteristics around a Double-Slotted Box Girder of a Long-Span Bridge during Vortex-Induced Vibration
    Wu, Fengying
    Wang, Zilong
    Zhao, Lin
    Pan, Tao
    Xiao, Haizhu
    Ge, Yaojun
    JOURNAL OF BRIDGE ENGINEERING, 2023, 28 (01)