Assessment of the Apical Transportation and Quantity of Root Canal Dentin Removed Using Different New Rotary File Systems: An Original Study

被引:0
|
作者
Singh, Harmeet [1 ]
Shukla, Anuj K. [2 ]
Jadhav, Apurva A. [3 ]
Shetty, Anshuman [4 ]
Shetty, Chitharanjan [4 ]
Dutta, Smita D. [5 ]
Mustafa, Mohammed [6 ]
机构
[1] Maharaja Ganga Singh Dent Coll, Dept Conservat Dent & Endodont, Sri Ganganagar, Rajasthan, India
[2] Govt Med Coll, Dept Dent, Ratlam, Madhya Pradesh, India
[3] GD POL Fdn, YMT Dent Coll, Dept Endodont, Kharghar, Maharashtra, India
[4] Nitte Deemed Be Univ, AB Shetty Mem Inst Dent Sci, Dept Conservat Dent & Endodont, Mangalore, Karnataka, India
[5] Qassim Univ, Dept Conservat Dent Sci & Endodont, Coll Dent, Buraydah, Saudi Arabia
[6] Sankalchand Patel Univ, Dept Conservat Dent & Endodont, Narsinhbhai Patel Dent Coll & Hosp, Visnagar, Gujarat, India
关键词
Canal transportation; dentine; rotary; SHAPING ABILITY; METALLURGICAL CHARACTERIZATION; MECHANICAL-PROPERTIES; BT-RACE; INSTRUMENTS; PROTAPER; MEMORY; TOMOGRAPHY; FRACTURE; MOLARS;
D O I
10.4103/jpbs.jpbs_440_22
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: The rotary systems have found a common application in the clinical practice for the endodontic therapies. Hence, we compared three recent endodontic systems for the comparison of the dentine removal and the apical transportation particularly in the curved canals. Methods: Oneshape, Pro Taper Next, and Edgefile X3 were the three systems that were compared. Thirty maxillary mesio buccal canals of the human permanent teeth were compared due to its curved nature. The volume of dentin removed and apical transportation (mm) were measured using micro-computed tomographic imaging (mm). Both the coronal section and the entire canal length had their dentin removed in accordance with measurements. Total dentine removed, coronal dentine removed, and the canal transportations were compared for the three rotary file systems. The values were compared with appropriate statistical tests for evaluating the significance. Results: There was no statistically significant difference between the three file systems for the dentin removed. The mean canal transportation was 0.33 +/- 0.12, 0.21 +/- 0.25, and 0.23 +/- 0.21 mm, respectively, for Oneshape, Pro Taper Next, and Typhoon CM. In terms of statistics, there were no appreciable variations among the three rotary tools for apical transfer. Conclusions: The three rotary systems were comparable for the apical transportation and the dentine removal. Despite variations in the magnitude of apical enlargements, none of the instrumentation methods detected apical transportation.
引用
收藏
页码:S141 / S145
页数:5
相关论文
共 41 条
  • [21] Canal transportation caused by one single-file and two multiple-file rotary systems: A comparative study using cone-beam computed tomography
    Saberi, Eshagh Ali
    Mollashahi, Narges Farhad
    Farahi, Forugh
    GIORNALE ITALIANO DI ENDODONZIA, 2018, 32 (02): : 57 - 62
  • [22] Comparative Assessment of Canal Transportation, Dentin Loss, and Remaining Root Filling Material by Different Retreatment Files - An in vitro Cross-Sectional Study
    Ali, Afzal
    Saraf, Prahiad
    Kamatagi, Laxmikant
    Khasnis, Sandhya
    CONTEMPORARY CLINICAL DENTISTRY, 2021, 12 (01) : 14 - 20
  • [23] Comparative Evaluation of the Removal of Gutta Percha From the Root Canal Using Various Retreatment File Systems With and Without Magnification: An In Vitro Study
    Arun, Nishitha
    Solete, Pradeep
    Jeevanandan, Ganesh
    Antony, Delphine P.
    Sairaman, Sruthi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (06)
  • [24] The Effect of Cervical Preflaring Using Different Rotary Nickel-Titanium Systems on the Accuracy of Apical File Size Determination
    Tennert, Christian
    Herbert, Josef
    Altenburgen, Markus Joerg
    Wrbas, Karl-Thomas
    JOURNAL OF ENDODONTICS, 2010, 36 (10) : 1669 - 1672
  • [25] Evaluation of Root Dentin Removal and Apical Debris Extrusion during Root Canal Preparation Related to the Different Endodontic Access Cavities: An In-vitro Study
    Modi, Shreya
    Joshi, Chintan
    Patel, Aashray
    Khunt, Ankita
    Parmar, Anisha
    Jadawala, Kruti
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2023, 17 (10) : ZC38 - ZC43
  • [26] Comparison of Cutting Efficiency and Safety of 10/0.04 RaCe and Mtwo Rotary File Systems in Reaching the Full Root Canal Working Length: An In Vitro Study
    Abedi, Pouya
    Gilani, Peiman
    Fathollahi, Mahmood Sheikh
    Iranmanesh, Foad
    DENTAL HYPOTHESES, 2022, 13 (01): : 6 - 9
  • [27] Compare the Centering Ability, Canal Transportation and Root Canal Area Increase of XP Endoshaper, Hyflex CM and K3 XF File System by using Cone Beam: An Original Research
    Vinodhini, V.
    Baig, Mirza M.
    Attur, Kailash
    Singh, Shalini
    Sharma, Sehaj
    Padda, Puneet
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S380 - S382
  • [28] Evaluation of the Effect of Rotary Systems on Stresses in a New Testing Model Using a 3-Dimensional Printed Simulated Resin Root with an Oval-shaped Canal: A Finite Element Analysis Study
    Eken, Rahmi
    Sen, Ozgur Genc
    Eskitascioglu, Gurcan
    Belli, Sema
    JOURNAL OF ENDODONTICS, 2016, 42 (08) : 1273 - 1278
  • [29] Evaluation of Apically Extruded Debris During Retreatment Procedures Using Various File Systems in Teeth With Simulated Apical Root Resorption: An In Vitro Study
    Gayatri, Sasti
    Mathew, Sebeena
    Kumaravadivel, Karthick
    Thangavel, Boopathi
    Thangaraj, Deepa N.
    Shaji, Athira
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (06)
  • [30] Light emitting diode assessment of dentinal microcracks after root canal preparation with 4 different heat-treated file systems
    Pandey, Sanket H.
    Patni, Pallav M.
    Jain, Pradeep
    Raghuwanshi, Swadhin
    Sanwatsarkar, Gauri
    Chaturvedi, Arpita
    MINERVA DENTAL AND ORAL SCIENCE, 2021, 70 (06) : 257 - 262