Assessment of the Apical Transportation and Quantity of Root Canal Dentin Removed Using Different New Rotary File Systems: An Original Study

被引:0
|
作者
Singh, Harmeet [1 ]
Shukla, Anuj K. [2 ]
Jadhav, Apurva A. [3 ]
Shetty, Anshuman [4 ]
Shetty, Chitharanjan [4 ]
Dutta, Smita D. [5 ]
Mustafa, Mohammed [6 ]
机构
[1] Maharaja Ganga Singh Dent Coll, Dept Conservat Dent & Endodont, Sri Ganganagar, Rajasthan, India
[2] Govt Med Coll, Dept Dent, Ratlam, Madhya Pradesh, India
[3] GD POL Fdn, YMT Dent Coll, Dept Endodont, Kharghar, Maharashtra, India
[4] Nitte Deemed Be Univ, AB Shetty Mem Inst Dent Sci, Dept Conservat Dent & Endodont, Mangalore, Karnataka, India
[5] Qassim Univ, Dept Conservat Dent Sci & Endodont, Coll Dent, Buraydah, Saudi Arabia
[6] Sankalchand Patel Univ, Dept Conservat Dent & Endodont, Narsinhbhai Patel Dent Coll & Hosp, Visnagar, Gujarat, India
关键词
Canal transportation; dentine; rotary; SHAPING ABILITY; METALLURGICAL CHARACTERIZATION; MECHANICAL-PROPERTIES; BT-RACE; INSTRUMENTS; PROTAPER; MEMORY; TOMOGRAPHY; FRACTURE; MOLARS;
D O I
10.4103/jpbs.jpbs_440_22
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: The rotary systems have found a common application in the clinical practice for the endodontic therapies. Hence, we compared three recent endodontic systems for the comparison of the dentine removal and the apical transportation particularly in the curved canals. Methods: Oneshape, Pro Taper Next, and Edgefile X3 were the three systems that were compared. Thirty maxillary mesio buccal canals of the human permanent teeth were compared due to its curved nature. The volume of dentin removed and apical transportation (mm) were measured using micro-computed tomographic imaging (mm). Both the coronal section and the entire canal length had their dentin removed in accordance with measurements. Total dentine removed, coronal dentine removed, and the canal transportations were compared for the three rotary file systems. The values were compared with appropriate statistical tests for evaluating the significance. Results: There was no statistically significant difference between the three file systems for the dentin removed. The mean canal transportation was 0.33 +/- 0.12, 0.21 +/- 0.25, and 0.23 +/- 0.21 mm, respectively, for Oneshape, Pro Taper Next, and Typhoon CM. In terms of statistics, there were no appreciable variations among the three rotary tools for apical transfer. Conclusions: The three rotary systems were comparable for the apical transportation and the dentine removal. Despite variations in the magnitude of apical enlargements, none of the instrumentation methods detected apical transportation.
引用
收藏
页码:S141 / S145
页数:5
相关论文
共 41 条
  • [1] Evaluation of the Amount of Root Canal Dentin Removed and Apical Transportation Occurrence after Instrumentation with ProTaper Next, OneShape, and EdgeFile Rotary Systems
    Yilmaz, Funda
    Eren, Irem
    Eren, Hakan
    Badi, Mustafa A.
    Ocak, Mert
    Celik, Hakan Hamdi
    JOURNAL OF ENDODONTICS, 2020, 46 (05) : 662 - 667
  • [2] Apical transportation and canal straightening with different continuously tapered rotary file systems in severely curved root canals: F6 SkyTaper and OneShape versus Mtwo
    Buerklein, S.
    Jaeger, P. G.
    Schaefer, E.
    INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (10) : 983 - 990
  • [3] Apical transportation during removal of root canal filling with different retreatment systems
    Saglam, Baran C.
    Cicek, Ersan
    Kocak, Mustafa M.
    Kocak, Sibel
    Kivanc, Bagdagul H.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2016, 39 (10) : 541 - 545
  • [4] Canal Transportation and Volumetric Dentin Removal Abilities of Ni-Ti Rotary File Systems in Curved Primary Root Canals: CBCT Study
    Islam, Aylin
    Unsal, Gurkan
    Almashharawi, Alaa
    APPLIED SCIENCES-BASEL, 2021, 11 (19):
  • [5] Comparative Evaluation of Root Dentin Integrity after Root Canal Preparation with Rotary File Systems of Different Ni-Ti Alloys
    Algarni, Youssef A.
    Elshinawy, Mohamed I.
    Nahi, Zainah A.
    Algarni, Asma S.
    Alghamdi, Nuha S.
    ANNALS OF MEDICAL AND HEALTH SCIENCES RESEARCH, 2019, 9 (03) : 614 - 620
  • [6] Cleaning Efficiency and Apical Transportation of Different Endodontic File Systems in Simulated Curved Root Canals
    Ivacson, Andrea Csinszka Kovacs
    Monea, Monica
    Kovacs, Monika
    Pop, Mihai
    Pacurar, Mariana
    Borda, Angela
    REVISTA DE CHIMIE, 2017, 68 (12): : 2892 - 2895
  • [7] A Comparative Study of Four Rotary Endodontic File Systems: Assessing Canal Transportation and Centering Ability using Cone-beam Computed Tomography
    Chhabra, Ajay
    Ramya, Kp
    Prathap, B. Saravana
    Murjani, Bhavana
    Yadav, Priyanka
    CONTEMPORARY CLINICAL DENTISTRY, 2025, 16 (01) : 44 - 48
  • [8] Computed tomography evaluation of root canal transportation using ProTaper, Race and Sendoline rotary systems: an ex vivo study
    Saberi, Eshaghali
    Aramesh, Bita
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2018, 10 : 93 - 98
  • [9] Effect of continuous irrigation on apical transportation, centering ability and volume of removed dentin in curved root canals: a micro computed tomography study
    Kirmizibekmez, Ozgen
    Karatas, Ertugrul
    Topcuoglu, Huseyin Sinan
    GIORNALE ITALIANO DI ENDODONZIA, 2022, 36 (02): : 30 - 38
  • [10] Efficiency of Different Nickel-Titanium Endodontic File Systems in Cleaning and Apical Transportation of Simulated Curved Root Canals
    Ivacson, Andrea Csinszka Kovacs
    Pacurar, Mariana
    Monea, Monica
    Kovacs, Monika
    Pop, M.
    Bechir, Anamaria
    Borda, Angela
    REVISTA DE CHIMIE, 2017, 68 (05): : 957 - 961