Long-term electrocardiogram signal quality assessment pipeline based on a frequency-adaptive mean absolute deviation curve

被引:3
作者
Yuan, Shuaiying [1 ]
He, Ziyang [1 ]
Zhao, Jianhui [1 ]
Yang, Zheng [2 ]
Yuan, Zhiyong [1 ]
机构
[1] Wuhan Univ, Sch Comp Sci, Wuhan 430072, Hubei, Peoples R China
[2] Wuhan Univ, Renmin Hosp, Wuhan 430060, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Mean Absolute Deviation(MAD); E-DWT Estimation; Frequency-adaptive; Electrocardiogram(ECG); Signal Quality Assessment(SQA); QRS DETECTION; LINE WANDER; ECG; REMOVAL; CLASSIFICATION; INTERFERENCE; INDEXES; SYSTEM;
D O I
10.1007/s10489-023-04549-w
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Health monitoring is hindered by various types of noise (especially motion artifacts) in electrocardiogram (ECG) collected via wearable devices. The main way to solve this problem is through denoising techniques or signal quality assessment(SQA). When denoising techniques cannot completely suppress motion artifacts, SQA is the most promising approach to address the problem. However, the performance of SQA based on morphological and RR interval features for expressing ECG quality features contaminated by motion artifacts remains unsatisfactory. Here, a frequency-adaptive pipeline based on the mean absolute deviation curve is proposed to achieve a simple and efficient SQA. The greatest advantage of the proposed pipeline is to implement SQA from a new perspective, without considering the influence of motion artifacts or paying attention to the morphological and RR interval features of ECG data. Specifically, the discrete wavelet transform (DWT) is used to capture the abrupt local changes in ECG and noise in a local time window and to form a curve that can reflect the ECG quality distribution. By setting thresholds appropriately (we select two threshold ranges: [0.107,0.143] and [0.324,0.390]), the curve can accurately reflect the ECG quality distribution and label it as three quality levels according to the noise-contamination degrees. On an artificial dataset based on the QT dataset, the F-1 value of our pipeline reaches 97.01%, outperforming the SQA method based on morphology and RR interval features. More importantly, the proposed pipeline achieves SQA without corrupting pathological information, and has great potential for deployment in wearable devices.
引用
收藏
页码:20418 / 20440
页数:23
相关论文
共 47 条
  • [1] Application of deep convolutional neural network for automated detection of myocardial infarction using ECG signals
    Acharya, U. Rajendra
    Fujita, Hamido
    Oh, Shu Lih
    Hagiwara, Yuki
    Tan, Jen Hong
    Adam, Muhammad
    [J]. INFORMATION SCIENCES, 2017, 415 : 190 - 198
  • [2] Fractal and EMD based removal of baseline wander and powerline interference from ECG signals
    Agrawal, Sakshi
    Gupta, Anubha
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (11) : 1889 - 1899
  • [3] Assessing the signal quality of electrocardiograms from varied acquisition sources: A generic machine learning pipeline for model generation
    Albaba, Adnan
    Simo, Neide
    Wang, Yuyang
    Hendriks, Richard C.
    De Raedt, Walter
    Van Hoof, Chris
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 130
  • [4] Assessing ECG signal quality on a coronary care unit
    Allen, J
    Murray, A
    [J]. PHYSIOLOGICAL MEASUREMENT, 1996, 17 (04) : 249 - 258
  • [5] ECG Signal Quality During Arrhythmia and Its Application to False Alarm Reduction
    Behar, Joachim
    Oster, Julien
    Li, Qiao
    Clifford, Gari D.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (06) : 1660 - 1666
  • [6] Clifford G., 2006, ADV METHODS TOOLS EC
  • [7] Signal quality indices and data fusion for determining clinical acceptability of electrocardiograms
    Clifford, G. D.
    Behar, J.
    Li, Q.
    Rezek, I.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2012, 33 (09) : 1419 - 1433
  • [8] Adapting to unknown smoothness via wavelet shrinkage
    Donoho, DL
    Johnstone, IM
    [J]. JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1995, 90 (432) : 1200 - 1224
  • [9] Cubic-spline interpolation: Part 1
    Dyer, SA
    Dyer, JS
    [J]. IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2001, 4 (01) : 44 - 46
  • [10] A COMPARISON OF THE NOISE SENSITIVITY OF 9 QRS DETECTION ALGORITHMS
    FRIESEN, GM
    JANNETT, TC
    JADALLAH, MA
    YATES, SL
    QUINT, SR
    NAGLE, HT
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) : 85 - 98