Experimental Analysis of the Mechanical Response of Masonry Columns Partially Confined with PBO FRCM (Fabric Reinforced Cementitious Mortar) Composites

被引:3
作者
Ombres, Luciano [1 ]
Campolongo, Francesco [1 ]
Guglielmi, Marielda [1 ]
Verre, Salvatore [2 ]
机构
[1] Univ Calabria, Dept Civil Engn, Arcavacata Rende, I-87063 Cosenza, Italy
[2] Univ E Campus, Fac Engn, via Isimbardi 10, I-22060 Novedrate, Italy
关键词
columns; composites; confinement; masonry; partial;
D O I
10.3390/ma16134812
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An experimental investigation on partially PBO (short of Polyparaphenylenebenzobisthiazole) FRCM (Fiber Reinforced Cementitious Mortar) confined clay brick masonry columns has been conducted. Ten small-scale specimens measuring 445 mm high with a square cross-section of the 250 mm side have been tested under monotonic axial loading until collapse. Two columns were unconfined, while the remaining ones were confined with single-layer PBO FRCM jackets varying the geometric configuration along their height. The vertical spacing ratio sf'/sf, being sf' and sf the center-to-center and the net spacings between two consecutive jackets, respectively, was considered as the key parameter of the confinement configuration. The failure modes, stress-strain curves and peak axial stress and strain values are reported. The experimental results have been compared to the predictions of models found in the Italian guidelines CNR DT 215/2018 and the American ACI 549-R20 standards. The main aspects analyzed involved (i) the evaluation of the effectiveness of partial confinement on the mechanical response of columns, (ii) the definition of the mechanical and geometrical parameters that influence the structural response of partially confined columns, and (iii) the development of appropriate analytical models for the prediction of the resisting capacity of masonry columns partially confined with PBO FRCM.
引用
收藏
页数:19
相关论文
共 33 条
  • [1] Masonry columns confined with fabric reinforced cementitious matrix (FRCM) systems: A round robin test
    Aiello, M. A.
    Bencardino, F.
    Cascardi, A.
    D'Antino, T.
    Fagone, M.
    Frana, I.
    La Mendola, L.
    Lignola, G. P.
    Mazzotti, C.
    Micelli, F.
    Minafo, G.
    Napoli, A.
    Ombres, L.
    Oddo, M. C.
    Poggi, C.
    Prota, A.
    Ramaglia, G.
    Ranocchiai, G.
    Realfonzo, R.
    Verre, S.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2021, 298
  • [2] Confinement of Masonry Columns with the FRCM-System: Theoretical and Experimental Investigation
    Aiello, Maria Antonietta
    Cascardi, Alessio
    Ombres, Luciano
    Verre, Salvatore
    [J]. INFRASTRUCTURES, 2020, 5 (11) : 1 - 14
  • [3] A new predictive model for FRCM-confined columns: A reflection on the composite behavior at peak stress
    Ameli, Zahra
    D'Antino, Tommaso
    Carloni, Christian
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2022, 337
  • [4] [Anonymous], 2018, 617 DM IT SUP COUNC
  • [5] [Anonymous], 2011, 7721 EN UNI
  • [6] [Anonymous], 2020, 2152018 CNRDT NAT RE
  • [7] [Anonymous], 2020, 549R20 ACI COMM
  • [8] [Anonymous], 2013, 139341 ISO EN
  • [9] [Anonymous], 2000, 12190 UNI EN
  • [10] [Anonymous], 2013, 200R1 CNRDT NAT RES