Alignment-Based Optically Pumped Magnetometer Using a Buffer-Gas Cell

被引:11
作者
Rushton, L. M. [1 ]
Elson, L. [1 ]
Meraki, A. [1 ]
Jensen, K. [1 ]
机构
[1] Univ Nottingham, Sch Phys & Astron, Univ Pk, Nottingham NG7 2RD, England
基金
英国工程与自然科学研究理事会;
关键词
Cells - Cytology - Gases - Laser beams - Magnetic fields - Magnetometers - Microfabrication - Optical pumping;
D O I
10.1103/PhysRevApplied.19.064047
中图分类号
O59 [应用物理学];
学科分类号
摘要
Alignment-based optically pumped magnetometers (OPMs) are capable of measuring oscillating mag-netic fields with high sensitivity in the fT/& RADIC;Hz range. Until now, alignment-based magnetometers have only used paraffin-coated vapour cells to extend the spin relaxation lifetimes of the alkali vapour. The drawback of these cells is that they are hand blown and are therefore time intensive, and somewhat unreliable, to produce. Buffer-gas cells, on the other hand, can be manufactured on a mass scale using microfabrication techniques. In this work we use hand-blown cells, but our methods also apply to micro -fabricated buffer-gas cells. We present the first demonstration of an alignment-based magnetometer using a buffer-gas vapour cell containing caesium (Cs) alkali vapour and nitrogen (N2) buffer gas. The OPM is operated at 55 degrees C and we achieve a 325 fT/& RADIC;Hz sensitivity to 10 kHz oscillating magnetic fields with an 800 Hz bandwidth. The alignment-based magnetometer uses a single low-power laser beam for optical pumping and probing and could potentially allow for more rapid commercialization of radio-frequency OPMs, due to the robustness of the one-beam geometry.
引用
收藏
页数:11
相关论文
共 53 条
[1]   High-resolution measurement of the pressure broadening and shift of the Cs D1 and D2 lines by N2 and He buffer gases -: art. no. 032708 [J].
Andalkar, A ;
Warrington, RB .
PHYSICAL REVIEW A, 2002, 65 (03) :7
[2]  
[Anonymous], 2023, MEDA MGCH 2 SINGLE A
[3]  
[Anonymous], 2023, BARTINGTON MAG639 WI
[4]   Can a quantum nondemolition measurement improve the sensitivity of an atomic magnetometer? [J].
Auzinsh, M ;
Budker, D ;
Kimball, DF ;
Rochester, SM ;
Stalnaker, JE ;
Sushkov, AO ;
Yashchuk, VV .
PHYSICAL REVIEW LETTERS, 2004, 93 (17) :173002-1
[5]  
Auzinsh M., 2014, OPTICALLY POLARIZED
[6]   Polarized Alkali-Metal Vapor with Minute-Long Transverse Spin-Relaxation Time [J].
Balabas, M. V. ;
Karaulanov, T. ;
Ledbetter, M. P. ;
Budker, D. .
PHYSICAL REVIEW LETTERS, 2010, 105 (07)
[7]   Suppression of the Nonlinear Zeeman Effect and Heading Error in Earth-Field-Range Alkali-Vapor Magnetometers [J].
Bao, Guzhi ;
Wickenbrock, Arne ;
Rochester, Simon ;
Zhang, Weiping ;
Budker, Dmitry .
PHYSICAL REVIEW LETTERS, 2018, 120 (03)
[8]   Theory of a 4He parametric-resonance magnetometer based on atomic alignment [J].
Beato, Francois ;
Belorizky, Elie ;
Labyt, Etienne ;
Le Prado, Matthieu ;
Palacios-Laloy, Agustin .
PHYSICAL REVIEW A, 2018, 98 (05)
[9]   Object detection with an alkali-metal spin maser [J].
Bevington, P. ;
Gartman, R. ;
Chalupczak, W. .
JOURNAL OF APPLIED PHYSICS, 2021, 130 (21)
[10]   Enhanced material defect imaging with a radio-frequency atomic magnetometer [J].
Bevington, P. ;
Gartman, R. ;
Chalupczak, W. .
JOURNAL OF APPLIED PHYSICS, 2019, 125 (09)