Deep Learning for Automatic Bone Marrow Apparent Diffusion Coefficient Measurements From Whole-Body Magnetic Resonance Imaging in Patients With Multiple Myeloma

被引:14
|
作者
Wennmann, Markus [1 ]
Neher, Peter [2 ]
Stanczyk, Nikolas [1 ,3 ]
Kahl, Kim-Celine [2 ]
Kaechele, Jessica [2 ]
Weru, Vivienn [4 ]
Hielscher, Thomas [4 ]
Groezinger, Martin [1 ]
Chmelik, Jiri [2 ,5 ]
Zhang, Kevin Sun [1 ]
Bauer, Fabian [1 ,3 ]
Nonnenmacher, Tobias [6 ]
Debic, Manuel [6 ]
Sauer, Sandra [7 ]
Rotkopf, Lukas Thomas [1 ,3 ]
Jauch, Anna [8 ]
Schlamp, Kai [6 ,9 ]
Mai, Elias Karl [7 ]
Weinhold, Niels [7 ]
Afat, Saif [10 ]
Horger, Marius [10 ]
Goldschmidt, Hartmut [7 ,11 ]
Schlemmer, Heinz-Peter [1 ]
Weber, Tim Frederik [6 ]
Delorme, Stefan [1 ]
Kurz, Felix Tobias [1 ]
Maier-Hein, Klaus [2 ,12 ]
机构
[1] German Canc Res Ctr, Div Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr, Div Med Image Comp, Heidelberg, Germany
[3] Heidelberg Univ, Med Fac, Heidelberg, Germany
[4] German Canc Res Ctr, Div Biostat, Heidelberg, Germany
[5] Brno Univ Technol, Fac Elect Engn & Commun, Dept Biomed Engn, Brno, Czech Republic
[6] Abt Diagnost & Intervent Radiol, Tubingen, Germany
[7] Heidelberg Univ Hosp, Dept Internal Med 5, Thorax Clin, Sect Multiple Myeloma, Heidelberg, Germany
[8] Heidelberg Univ Hosp, Inst Human Genet, Thorax Clin, Heidelberg, Germany
[9] Heidelberg Univ Hosp, Dept Diagnost & Intervent Radiol Nucl Med, Thorax Clin, Heidelberg, Germany
[10] Eberhard Karls Univ Tubingen, Tuebingen Univ Hosp, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[11] Univ Hosp Heidelberg, Natl Ctr Tumor Dis NCT, Heidelberg, Germany
[12] Univ Hosp Heidelberg, Dept Radiat Oncol, Pattern Anal & Learning Grp, Heidelberg, Germany
关键词
deep learning; segmentation; diffusion-weighted imaging; apparent diffusion coefficient; whole-body; magnetic resonance imaging; multiple myeloma; monoclonal plasma cell disorders; bone marrow; multicenter; INTERNATIONAL STAGING SYSTEM; INDEPENDENT PREDICTOR; EARLY RESPONSE; WEIGHTED MRI; SEGMENTATION; CRITERIA; ADULTS; MAPS; DWI;
D O I
10.1097/RLI.0000000000000932
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesDiffusion-weighted magnetic resonance imaging (MRI) is increasingly important in patients with multiple myeloma (MM). The objective of this study was to train and test an algorithm for automatic pelvic bone marrow analysis from whole-body apparent diffusion coefficient (ADC) maps in patients with MM, which automatically segments pelvic bones and subsequently extracts objective, representative ADC measurements from each bone.Materials and MethodsIn this retrospective multicentric study, 180 MRIs from 54 patients were annotated (semi)manually and used to train an nnU-Net for automatic, individual segmentation of the right hip bone, the left hip bone, and the sacral bone. The quality of the automatic segmentation was evaluated on 15 manually segmented whole-body MRIs from 3 centers using the dice score. In 3 independent test sets from 3 centers, which comprised a total of 312 whole-body MRIs, agreement between automatically extracted mean ADC values from the nnU-Net segmentation and manual ADC measurements from 2 independent radiologists was evaluated. Bland-Altman plots were constructed, and absolute bias, relative bias to mean, limits of agreement, and coefficients of variation were calculated. In 56 patients with newly diagnosed MM who had undergone bone marrow biopsy, ADC measurements were correlated with biopsy results using Spearman correlation.ResultsThe ADC-nnU-Net achieved automatic segmentations with mean dice scores of 0.92, 0.93, and 0.85 for the right pelvis, the left pelvis, and the sacral bone, whereas the interrater experiment gave mean dice scores of 0.86, 0.86, and 0.77, respectively. The agreement between radiologists' manual ADC measurements and automatic ADC measurements was as follows: the bias between the first reader and the automatic approach was 49 x 10-6 mm2/s, 7 x 10-6 mm2/s, and -58 x 10-6 mm2/s, and the bias between the second reader and the automatic approach was 12 x 10-6 mm2/s, 2 x 10-6 mm2/s, and -66 x 10-6 mm2/s for the right pelvis, the left pelvis, and the sacral bone, respectively. The bias between reader 1 and reader 2 was 40 x 10-6 mm2/s, 8 x 10-6 mm2/s, and 7 x 10-6 mm2/s, and the mean absolute difference between manual readers was 84 x 10-6 mm2/s, 65 x 10-6 mm2/s, and 75 x 10-6 mm2/s. Automatically extracted ADC values significantly correlated with bone marrow plasma cell infiltration (R = 0.36, P = 0.007).ConclusionsIn this study, a nnU-Net was trained that can automatically segment pelvic bone marrow from whole-body ADC maps in multicentric data sets with a quality comparable to manual segmentations. This approach allows automatic, objective bone marrow ADC measurements, which agree well with manual ADC measurements and can help to overcome interrater variability or nonrepresentative measurements. Automatically extracted ADC values significantly correlate with bone marrow plasma cell infiltration and might be of value for automatic staging, risk stratification, or therapy response assessment.
引用
收藏
页码:273 / 282
页数:10
相关论文
共 50 条
  • [41] Diffusion-weighted magnetic resonance imaging of mandibular bone marrow: do apparent diffusion coefficient values of the cervical vertebrae and mandible correlate with age?
    Luciana Munhoz
    Reinaldo Abdala Júnior
    Isabela Goulart Gil Choi
    Emiko Saito Arita
    Oral Radiology, 2022, 38 : 72 - 79
  • [42] Diffusion-weighted magnetic resonance imaging of mandibular bone marrow: do apparent diffusion coefficient values of the cervical vertebrae and mandible correlate with age?
    Munhoz, Luciana
    Abdala Junior, Reinaldo
    Gil Choi, Isabela Goulart
    Arita, Emiko Saito
    ORAL RADIOLOGY, 2022, 38 (01) : 72 - 79
  • [43] Monitoring bone marrow lesions by magnetic resonance imaging in patients with multiple myeloma after autologous stem-cell transplantation
    Solovyev, M., V
    Mendeleeva, L. P.
    Yatsyk, G. A.
    Lutsik, N. S.
    Firsova, M., V
    Gemdzhian, E. G.
    Savchenko, V. G.
    GEMATOLOGIYA I TRANSFUZIOLOGIYA, 2018, 63 (02): : 103 - 112
  • [44] Whole-body magnetic resonance imaging for detecting bone metastases: Comparison with bone scintigraphy
    Cascini G.
    Falcone C.
    Greco C.
    Bertucci B.
    Cipullo S.
    Tamburrini O.
    La radiologia medica, 2008, 113 (8) : 1157 - 1170
  • [45] Evaluation of Diffuse Bone Marrow Infiltration Pattern in Monoclonal Plasma Cell Diseases by Quantitative Whole-body Magnetic Resonance Imaging
    Sun, Mengtian
    Cheng, Jingliang
    Ren, Cuiping
    Zhang, Yong
    Li, Yinhua
    Wang, Linlin
    Zhang, Suping
    Lin, Liangjie
    ACADEMIC RADIOLOGY, 2022, 29 (04) : 490 - 500
  • [46] Whole-body magnetic resonance imaging for detecting bone metastases: comparison with bone scintigraphy
    Cascini, G.
    Falcone, C.
    Greco, C.
    Bertucci, B.
    Cipullo, S.
    Tamburrini, O.
    RADIOLOGIA MEDICA, 2008, 113 (08): : 1157 - 1170
  • [47] Prognostic significance of magnetic resonance imaging of bone marrow in previously untreated patients with multiple myeloma
    Moulopoulos, LA
    Gika, D
    Anagnostopoulos, A
    Delasalle, K
    Weber, D
    Alexanian, R
    Dimopoulos, MA
    ANNALS OF ONCOLOGY, 2005, 16 (11) : 1824 - 1828
  • [49] 3D CNN-based Deep Learning Model-based Explanatory Prognostication in Patients with Multiple Myeloma using Whole-body MRI
    Morita, Kento
    Karashima, Shigehiro
    Terao, Toshiki
    Yoshida, Kotaro
    Yamashita, Takeshi
    Yoroidaka, Takeshi
    Tanabe, Mikoto
    Imi, Tatsuya
    Zaimoku, Yoshitaka
    Yoshida, Akiyo
    Maruyama, Hiroyuki
    Iwaki, Noriko
    Aoki, Go
    Kotani, Takeharu
    Murata, Ryoichi
    Miyamoto, Toshihiro
    Machida, Youichi
    Matsue, Kosei
    Nambo, Hidetaka
    Takamatsu, Hiroyuki
    JOURNAL OF MEDICAL SYSTEMS, 2024, 48 (01)
  • [50] Apparent diffusion coefficient measurements with diffusion-weighted magnetic resonance imaging for evaluation of hepatic fibrosis
    Koinuma, M
    Ohashi, I
    Hanafusa, K
    Shibuya, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (01) : 80 - 85