A Preclinical Feasibility Study of Single-Port Robotic Subcostal Anatomical Lung Resection and Subxiphoid Thymectomy Using the da Vinci(R) SP System

被引:9
|
作者
Wu, Ching Feng [1 ]
Cheng, Chuan [2 ]
Suen, Ka Hei [3 ]
Stein, Hubert [3 ]
Chao, Yin Kai [1 ]
机构
[1] Chang Gung Univ, Chang Gung Mem Hosp Linkou, Coll Med, Div Thorac Surg, Taoyuan, Taiwan
[2] New Taipei Municipal Tu Cheng Hosp, Div Thorac Surg, New Taipei 25162, Taiwan
[3] Intuit Surg Inc, Dept Surg Applicat Engn, Sunnyvale, CA 94086 USA
关键词
da Vinci(R) SP system; single-port thoracic surgery; subxiphoid surgery; subcostal surgery; CLINICAL-TRIAL; SURGERY;
D O I
10.3390/diagnostics13030460
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Despite the recent introduction of technologically advanced single-port (SP) robotic systems, their use in the field of thoracic surgery has been rarely explored. Here, we report our preclinical experience concerning SP robotic thoracic surgery using the da Vinci(R) SP system. The da Vinci(R) SP system was used to perform subcostal anatomical lung resection and subxiphoid thymectomy in three cadavers. The operative settings that best met the surgeon's requirements for each resection were also determined. Four subcostal anatomical lung resections and two subxiphoid thymectomies were completed. While both procedures did not require additional incisions, the use of an observation port in the intercostal spaces was strongly recommended to safely create subcostal access. Dissection of hilar structures and mediastinal lymph nodes was feasible. However, due to the current unavailability of a robotic stapler, a handheld stapling instrument was required to perform a transection of vital structures. When the stapling process proved to be difficult, the table surgeon temporarily removed a robotic arm to acquire the necessary space to complete the procedure. Our data represent a promising preclinical step in understanding the feasibility of using the da Vinci(R) SP system to perform an SP subcostal anatomical lung resection and a subxiphoid thymectomy.
引用
收藏
页数:8
相关论文
共 19 条
  • [1] Technical feasibility of da Vinci SP single-port robotic cholecystectomy: a case report
    Cruz, Charles Jimenez
    Yang, Hye Yeon
    Kang, Incheon
    Kang, Chang Moo
    Lee, Woo Jung
    ANNALS OF SURGICAL TREATMENT AND RESEARCH, 2019, 97 (04) : 217 - 221
  • [2] Robotic Single-Port Donor Nephrectomy with the da Vinci SP® Surgical System
    Garden, Evan B.
    Al-Alao, Osama
    Razdan, Shirin
    Mullen, Gregory R.
    Florman, Sander
    Palese, Michael A.
    JSLS-JOURNAL OF THE SOCIETY OF LAPAROENDOSCOPIC SURGEONS, 2021, 25 (04)
  • [3] Subxiphoid Single-Port Robotic Thymectomy Using the Single-Port Robotic System versus VATS: A Multi-Institutional, Retrospective, and Propensity Score-Matched Study
    Lee, Jun Hee
    Hwang, Jinwook
    Park, Tae Hyun
    Gu, Byung Mo
    Jung, Younggi
    Yi, Eunjue
    Lee, Sungho
    Hwang, Soon Young
    Chung, Jae ho
    Kim, Hyun Koo
    CANCERS, 2024, 16 (16)
  • [4] A retrospective multicentre study on the evaluation of perioperative outcomes of single-port robotic cholecystectomy comparing the Xi and SP versions of the da Vinci robotic surgical system
    Kang, Yoon Hyung
    Kang, Jae Seung
    Cho, Yo Seok
    Kim, Hyeong Seok
    Lee, Mirang
    Han, Youngmin
    Sohn, Hee Ju
    Kim, Hongbeom
    Kwon, Wooil
    Jang, Jin-Young
    Lee, Hyeon Kook
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2022, 18 (01)
  • [5] Adrenalectomy Performed with the Da Vinci Single-Port Robotic System: A Systematic Review and Pooled Analysis
    Reitano, Giuseppe
    Tumminello, Arianna
    Prevato, Carlo
    Cacco, Anna
    Gaggiato, Greta
    Bau, Giorgia
    Sabato, Lorenzo
    Tonet, Elisa
    Gambarotto, Anna
    Fusca, Valerio
    Martina, Kevin
    Visentin, Silvia
    Betto, Giovanni
    Novara, Giacomo
    Dal Moro, Fabrizio
    Zattoni, Fabio
    CANCERS, 2025, 17 (08)
  • [6] Transoral robotic thyroidectomy on two human cadavers using the Intuitive da Vinci single port robotic surgical system and CO2 insufflation: Preclinical feasibility study
    Park, Dawon
    Shaear, Mohammad
    Chen, Yu-Hsien
    Russell, Jonathon O.
    Kim, Hoon Yub
    Tufano, Ralph P.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2019, 41 (12): : 4229 - 4233
  • [7] Single-port robotic-assisted laparoscopic sacrocolpopexy with magnetic retraction: first experience using the SP da Vinci platform
    Ganesan, Vishnu
    Goueli, Ramy
    Rodriguez, Dayron
    Hess, Deborah
    Carmel, Maude
    JOURNAL OF ROBOTIC SURGERY, 2020, 14 (05) : 753 - 758
  • [8] Single-Port Versus Multiport da Vinci System for Transoral Robotic Surgery of Hypopharyngeal and Laryngeal Carcinoma
    Sampieri, Claudio
    Pirola, Francesca
    Costantino, Andrea
    Kim, Dahee
    Ho, Jung J.
    Lee, Kyuin
    De Virgilio, Armando
    Park, Young M.
    Kim, Se-Heon
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2023, 169 (03) : 548 - 555
  • [9] Transoral robotic surgery in oropharyngeal squamous cell carcinoma: A comparative study between da Vinci Single-Port and da Vinci Xi systems
    Costantino, Andrea
    Sampieri, Claudio
    Meliante, Piero Giuseppe
    De Virgilio, Armando
    Kim, Se-Heon
    ORAL ONCOLOGY, 2024, 148
  • [10] First report comparing the two types of single-incision robotic sacrocolpopexy: Single site using the da Vinci Xi or Si system and single port using the da Vinci SP system
    Lee, Sa Ra
    Roh, A-mi
    Jeong, Kyungah
    Kim, Sung Hoon
    Chae, Hee Dong
    Moon, Hye-Sung
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2021, 60 (01): : 60 - 65