A transformer-based dual-domain network for reconstructing FOV extended cone-beam CT images from truncated sinograms in radiation therapy

被引:1
作者
Gao, Liugang [1 ,2 ,3 ]
Xie, Kai [2 ,3 ]
Sun, Jiawei [2 ,3 ]
Lin, Tao [2 ,3 ]
Sui, Jianfeng [2 ,3 ]
Yang, Guanyu [1 ]
Ni, Xinye [2 ,3 ]
机构
[1] Southeast Univ, Sch Comp Sci & Engn, Nanjing, Peoples R China
[2] Nanjing Med Univ, Affiliated Changzhou Peoples Hosp 2, Changzhou, Peoples R China
[3] Jiangsu Prov Engn Res Ctr Med Phys, Changzhou, Peoples R China
关键词
CBCT; Sinogram; FOV; Reconstruction; Radiation therapy; FIELD-OF-VIEW; COMPUTED-TOMOGRAPHY; ALGORITHM;
D O I
10.1016/j.cmpb.2023.107767
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Cone-beam computed tomography (CBCT) is widely used in clinical radiotherapy, but its small field of view (sFOV) limits its application potential. In this study, a transformer-based dual-domain network (dual_swin), which combined image domain restoration and sinogram domain restoration, was proposed for the reconstruction of complete CBCT images with extended FOV from truncated sinograms.Methods: The planning CT images with large FOV (LFOV) of 330 patients who received radiation therapy were collected. The synthetic CBCT (sCBCT) images with LFOV were generated from CT images by the trained cycleGAN network, and CBCT images with sFOV were obtained through forward projection, projection truncation, and filtered back projection (FBP), comprising the training and test data. The proposed dual_swin includes sinogram domain restoration, image domain restoration, and FBP layer, and the swin transformer blocks were used as the basic feature extraction module in the network to improve the global feature extraction ability. The proposed dual_swin was compared with the image domain method, the sinogram domain method, the U-Net based dual domain network (dual_Unet), and the traditional iterative reconstruction method based on prior image and conjugate gradient least-squares (CGLS) in the test of sCBCT images and clinical CBCT images. The HU accuracy and body contour accuracy of the predicted images by each method were evaluated.Results: The images generated using the CGLS method were fuzzy and obtained the lowest structural similarity (SSIM) among all methods in the test of sCBCT and clinical CBCT images. The predicted images by the image domain methods are quite different from the ground truth and have low accuracy on HU value and body contour. In comparison with image domain methods, sinogram domain methods improved the accuracy of HU value and body contour but introduced secondary artifacts and distorted bone tissue. The proposed dual_swin achieved the highest HU and contour accuracy with mean absolute error (MAE) of 23.0 HU, SSIM of 95.7%, dice similarity coefficient (DSC) of 99.6%, and Hausdorff distance (HD) of 4.1 mm in the test of sCBCT images. In the test of clinical patients, images that were predicted by dual_swin yielded MAE, SSIM, DSC, and HD of 38.2 HU, 91.7%, 99.0%, and 5.4 mm, respectively. The predicted images by the proposed dual_swin has significantly higher accuracy than the other methods (P < 0.05).Conclusions: The proposed dual_swin can accurately reconstruct FOV extended CBCT images from the truncated sinogram to improve the application potential of CBCT images in radiotherapy.
引用
收藏
页数:12
相关论文
共 26 条
  • [1] Reducing axial truncation artifacts in iterative cone-beam CT for radiation therapy using a priori preconditioned information
    Cai, Meng
    Byrne, Mikel
    Ben Archibald-Heeren
    Metcalfe, Peter
    Rosenfeld, Anatoly
    Wang, Yang
    [J]. MEDICAL PHYSICS, 2021, 48 (11) : 7089 - 7098
  • [2] Cao H., 2021, arXiv
  • [3] Dosovitskiy A, 2021, INT C LEARNING REPRE
  • [4] Evaluation of a cycle-generative adversarial network-based cone-beam CT to synthetic CT conversion algorithm for adaptive radiation therapy
    Eckl, Miriam
    Hoppen, Lea
    Sarria, Gustavo R.
    Boda-Heggemann, Judit
    Simeonova-Chergou, Anna
    Steil, Volker
    Giordano, Frank A.
    Fleckenstein, Jens
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 308 - 316
  • [5] Evaluation of novel AI-based extended field-of-view CT reconstructions
    Fonseca, Gabriel Paiva
    Baer-Beck, Matthias
    Fournie, Eric
    Hofmann, Christian
    Rinaldi, Ilaria
    Ollers, Michel C.
    van Elmpt, Wouter J. C.
    Verhaegen, Frank
    [J]. MEDICAL PHYSICS, 2021, 48 (07) : 3583 - 3594
  • [6] Fournie E., 2019, Medical Imaging with Deep Learning (MIDL)
  • [7] Paired cycle-GAN-based image correction for quantitative cone-beam computed tomography
    Harms, Joseph
    Lei, Yang
    Wang, Tonghe
    Zhang, Rongxiao
    Zhou, Jun
    Tang, Xiangyang
    Curran, Walter J.
    Liu, Tian
    Yang, Xiaofeng
    [J]. MEDICAL PHYSICS, 2019, 46 (09) : 3998 - 4009
  • [8] Helgason S., 1965, ACTA MATH-DJURSHOLM, V113, P153, DOI [10.1007/BF02391776, DOI 10.1007/BF02391776]
  • [9] A novel reconstruction algorithm to extend the CT scan field-of-view
    Hsieh, J
    Chao, E
    Thibault, J
    Grekowicz, B
    Horst, A
    McOlash, S
    Myers, TJ
    [J]. MEDICAL PHYSICS, 2004, 31 (09) : 2385 - 2391
  • [10] Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy
    Islam, Mohammad K.
    Purdie, Thomas G.
    Norrlinger, Bernhard D.
    Alasti, Hamideh
    Moseley, Douglas J.
    Sharpe, Michael B.
    Siewerdsen, Jeffrey H.
    Jaffray, David A.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1573 - 1582