Thermal assessment of lithium-ion battery pack system with heat pipe assisted passive cooling using Simulink

被引:12
作者
Kim, Dae Yun [1 ]
Lee, Byeongyong [2 ]
Kim, Myeongjin [3 ]
Moon, Joo Hyun [4 ]
机构
[1] LG Display Co Ltd, Virtual Design Dept, Seoul, South Korea
[2] Pusan Natl Univ, Sch Mech Engn, Pusan, South Korea
[3] Kyungpook Natl Univ, Dept Hydrogen & Renewable Energy, Daegu, South Korea
[4] Hanbat Natl Univ, Dept Bldg & Plant Engn, Daejeon, South Korea
基金
新加坡国家研究基金会;
关键词
Battery pack; Computational Fluid Dynamics (CFD); Lithium -ion battery; Simulink; Heat pipe; Passive cooling devices; Thermal management; MANAGEMENT-SYSTEM; PERFORMANCE; MODULE;
D O I
10.1016/j.tsep.2023.102230
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study explores a novel application of heat pipes as passive cooling devices, addressing complex electric resistance behaviors in lithium-ion batteries, which lead to manufacturing and thermal safety issues. The aim is to effectively manage battery temperatures, thereby reducing manufacturing and operational costs. An innovative heat generation model was designed based on the Equivalent Circuit Model, leveraging Simulink and MATLAB to predict battery pack power. This intricate electrochemical calculation process is integrated and validated with system-level thermal modeling to compare the viability of heat pipe specifications and to forecast cooling availability via simulation. This research presents both numerical and experimental validations for voltage, state of charge, and cell temperatures. Crucially, we found that in high power output scenarios, such as at rates from 4C to 8C, the use of a heat pipe can reduce the temperature deviation between the cell and the ambient environment to less than three degrees. Furthermore, this paper discusses battery pack system configurations to compare thermal resistance between active and passive cooling systems. This study's novelty lies in its integrated approach to thermal management using heat pipes in the context of lithium-ion batteries, an aspect that has not been extensively explored in previous literature yet. It points to a new direction for future passive cooling strategies in battery pack thermal management.
引用
收藏
页数:14
相关论文
共 45 条
[31]   Boiling-driven, wickless, and orientation-independent thermal ground plane [J].
Moon, Joo Hyun ;
Fadda, Dani ;
Shin, Dong Hwan ;
Kim, Jin Sub ;
Lee, Jungho ;
You, Seung M. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 167
[32]   Thermal performance of liquid cooling based thermal management system for cylindrical lithium-ion battery module with variable contact surface [J].
Rao, Zhonghao ;
Qian, Zhen ;
Kuang, Yong ;
Li, Yimin .
APPLIED THERMAL ENGINEERING, 2017, 123 :1514-1522
[33]   A large scale Titanium Thermal Ground Plane [J].
Sigurdson, Mann ;
Liu, YuWei ;
Bozorgi, Payam ;
Bothman, David ;
MacDonald, Noel ;
Meinhart, Carl .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 62 :178-183
[34]   Battery thermal management system for electric vehicle using heat pipes [J].
Smith, Joshua ;
Singh, Randeep ;
Hinterberger, Michael ;
Mochizuki, Masataka .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 134 :517-529
[35]   Thermal analysis of conjugated cooling configurations using phase change material and liquid cooling techniques for a battery module [J].
Song, Limin ;
Zhang, Hengyun ;
Yang, Chun .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 133 :827-841
[36]   Three-dimensional thermal modeling of a lithium-ion battery pack [J].
Sun, Hongguang ;
Wang, Xiaohui ;
Tossan, Brian ;
Dixon, Regan .
JOURNAL OF POWER SOURCES, 2012, 206 :349-356
[37]   A state-of-the art review on advancing battery thermal management systems for fast-charging [J].
Thakur, Amrit Kumar ;
Sathyamurthy, Ravishankar ;
Velraj, R. ;
Saidur, R. ;
Pandey, A. K. ;
Ma, Z. ;
Singh, Punit ;
Hazra, Soumya Kanti ;
Sharshir, Swellam Wafa ;
Prabakaran, Rajendran ;
Kim, Sung Chul ;
Panchal, Satyam ;
Ali, Hafiz Muhammad .
APPLIED THERMAL ENGINEERING, 2023, 226
[38]   Adaptive state of charge algorithm for nickel metal hydride batteries including hysteresis phenomena [J].
Verbrugge, M ;
Tate, E .
JOURNAL OF POWER SOURCES, 2004, 126 (1-2) :236-249
[39]   Experimental investigations of thermal resistance of a heat sink with horizontal embedded heat pipes [J].
Wang, Jung-Chang ;
Huang, Hsiang-Sheng ;
Chen, Sih-Li .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2007, 34 (08) :958-970
[40]   Optimization of liquid cooling technology for cylindrical power battery module [J].
Wang, Ye ;
Zhang, Guoqing ;
Yang, Xiaoqing .
APPLIED THERMAL ENGINEERING, 2019, 162