Evaluating Contrast Sensitivity in Early and Intermediate Age-Related Macular Degeneration With the Quick Contrast Sensitivity Function

被引:6
|
作者
Anders, Philipp [1 ,2 ,3 ,4 ]
Traber, Ghislaine L. [1 ]
Hall, Ursula [1 ]
Garobbio, Simona A. [5 ]
Chan, Eric J. [1 ]
Gabrani, Chrysoula [1 ]
Camenzind, Hanna
Pfau, Maximilian [1 ,2 ]
Herzog, Michael [5 ]
Scholl, Hendrik P. N. [1 ,2 ]
机构
[1] Inst Mol & Clin Ophthalmol Basel, Mittlere Str 91, CH-4031 Basel, Switzerland
[2] Univ Basel, Dept Ophthalmol, Basel, Switzerland
[3] Ctr Hosp & Univ Coimbra CHUC, Ophthalmol Unit, Coimbra, Portugal
[4] Assoc Innovat & Biomed Res Light & Image, AIBILI, Coimbra, Portugal
[5] Ecole Polytech Fed Lausanne EPFL, Lab Psychophy, Lausanne, Switzerland
基金
瑞士国家科学基金会; 英国惠康基金;
关键词
age-related macular degeneration (AMD); quick contrast sensitivity function (qCSF); lower spatial frequencies; candidate functional markers; EYE DISEASE; MICROPERIMETRY; PIGMENT; AREDS;
D O I
10.1167/iovs.64.14.7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The purpose of this study was to describe, validate, and compare the contrast sensitivity functions (CSFs) acquired with the novel quick CSF (qCSF) method from patients with early and intermediate age-related macular degeneration (eAMD and iAMD) and healthy controls. METHODS. This is a cross-sectional analysis of contrast sensitivity (CS) and visual acuity (VA) baseline data from the prospective Multimodal Functional and Structural Visual System Characterization (MUMOVI) study. The qCSF testing was conducted with the manifold contrast vision meter (Adaptive Sensory Technology, San Diego, CA, USA). CS levels at spatial frequencies from 1 cycle per degree (CPD) to 18 CPD, the area underneath the logarithmic contrast sensitivity function (AULCSF), and contrast acuity (CA) were analyzed. The association of functional metrics with variables of interest was tested with linear models. RESULTS. Ninety-four study eyes from 94 study patients were included in the analysis (13 patients with eAMD, 33 patients with iAMD, and 48 healthy controls). Significant differences between the eAMD and the iAMD model estimates were only found for CS at 1 CPD (t value = -2.9, P value = 0.006) and CS at 1.5 CPD (-2.7, 0.01). A specific association between smoking years and CS at 1 CPD (P = 0.02) and CS at 1.5 CPD (P = 0.03) could be described in patients with AMD. CONCLUSIONS. The qCSF testing allows the fast measurement of the whole CSF, enabling the integration into clinical routine. We showed that novel qCSF-derived metrics detect slight functional differences between AMD stages, which testing by Pelli-Robson charts or VA testing would miss. This study, therefore, yields novel qCSF-derived candidate metrics for therapeutic trials in AMD.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Retinal Sensitivity in Macular Subfields and Their Association with Contrast Sensitivity in Early and Intermediate Age-Related Macular Degeneration
    Chan, Eric J.
    Anders, Philipp
    Garobbio, Simona A.
    Hall, Ursula
    Gabrani, Chrysoula
    Pfau, Kristina
    Zuche, Hanna Camenzind
    Futterknecht, Stefan
    Pfau, Maximilian
    Herzog, Michael
    Traber, Ghislaine L.
    Scholl, Hendrik P. N.
    OPHTHALMIC RESEARCH, 2024, 67 (01) : 458 - 469
  • [2] VISUAL FUNCTION MEASURES IN EARLY AND INTERMEDIATE AGE-RELATED MACULAR DEGENERATION
    Chandramohan, Arthika
    Stinnett, Sandra S.
    Petrowski, John T.
    Schuman, Stefanie G.
    Toth, Cynthia A.
    Cousins, Scott W.
    Lad, Eleonora M.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (05): : 1021 - 1031
  • [3] Home Monitoring of Retinal Sensitivity on a Tablet Device in Intermediate Age-Related Macular Degeneration
    Adams, Matthew
    Ho, Chi Yun Doreen
    Baglin, Elizabeth
    Sharangan, Pyrawy
    Wu, Zhichao
    Lawson, David J.
    Luu, Chi D.
    Turpin, Andrew
    McKendrick, Allison M.
    Guymer, Robyn H.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (05):
  • [4] Assessment of macular function by microperimetry in intermediate age-related macular degeneration
    Dinc, U. A.
    Yenerel, M.
    Gorgun, E.
    Oncel, M.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (04) : 595 - 600
  • [5] Macular function in eyes with early age-related macular degeneration with or without contralateral late age-related macular degeneration
    Parisi, Vincenzo
    Perillo, Loredana
    Tedeschi, Massimiliano
    Scassa, Cecilia
    Gallinaro, Geltrude
    Capaldo, Nicoletta
    Varano, Monica
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2007, 27 (07): : 879 - 890
  • [6] Normal- and Low-Luminance Automated Quantitative Contrast Sensitivity Assessment in Eyes With Age-Related Macular Degeneration
    Ou, William C.
    Lesmes, Luis Andres
    Christie, Abigail H.
    Denlar, Renee A.
    Csaky, Karl G.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 226 : 148 - 155
  • [7] Choroidal Thickness and Microperimetry Sensitivity in Age-Related Macular Degeneration
    Broadhead, Geoffrey K.
    Hong, Thomas
    McCluskey, Peter
    Grigg, John R.
    Schlub, Timothy E.
    Chang, Andrew A.
    OPHTHALMIC RESEARCH, 2017, 58 (01) : 27 - 34
  • [8] Impairment of Neurovascular Function in Intermediate Age-Related Macular Degeneration
    Bui, Bang
    Guymer, Robyn H.
    Heriot, Wilson
    Metha, Andrew
    Luu, Chi D.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (11):
  • [9] Spatial Cluster Patterns of Retinal Sensitivity Loss in Intermediate Age-Related Macular Degeneration Features
    Trinh, Matt
    Kalloniatis, Michael
    Alonso-Caneiro, David
    Nivison-Smith, Lisa
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (09):
  • [10] Mesopic Pelli-Robson contrast sensitivity and MP-1 microperimetry in healthy ageing and age-related macular degeneration
    Maynard, Michelle L.
    Zele, Andrew J.
    Feigl, Beatrix
    ACTA OPHTHALMOLOGICA, 2016, 94 (08) : E772 - E778