Novel Hotspot Temperature Prediction of Oil-Immersed Distribution Transformers: An Experimental Case Study

被引:15
|
作者
Abdali, Ali [1 ,2 ]
Abedi, Ali [1 ]
Mazlumi, Kazem [3 ]
Rabiee, Abbas [3 ]
Guerrero, Josep M. [4 ]
机构
[1] Kooshkan Transformers Co, R&D Dept, Zanjan 1991647113, Iran
[2] Univ Zanjan, Fac Engn, Dept Elect Engn, Zanjan 4537138791, Iran
[3] Univ Zanjan, Fac Engn, Dept Elec tr Engn, Zanjan 4537138791, Iran
[4] Aalborg Univ, CROM Ctr Res Microgrids, AAU Energy, DK-9220 Aalborg, Denmark
关键词
Oil insulation; Mathematical models; Power transformer insulation; Windings; Transformers; Oils; IEC Standards; Computational fluid dynamics (CFD); corrugated wall distribution transformer (DT); hotspot temperature (HST); optical fiber sensor (OFS); thermal camera; HOT-SPOT TEMPERATURE; POWER TRANSFORMER; MODEL; OPTIMIZATION; MANAGEMENT;
D O I
10.1109/TIE.2022.3206690
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Distribution transformers (DTs) are deemed fundamental and high-priced equipment for power grids, and their failure influences grid reliability. The continuity of DT operation highly depends on its insulation conditions and following that to the hotspot temperature (HST). In this article, a novel formula is proposed for HST prediction of DTs by considering the effective electrical and mechanical parameters on heat dissipation capacity. Additionally, complete and accurate 3D modeling based on computational fluid dynamics (CFD) is presented to validate the proposed novel formula for HST prediction. In this modeling, the conservator, which plays a key role in the HST value, is accurately modeled. Optical fiber sensors are utilized in the studied 500-kVA DT to verify the accuracy of the proposed HST prediction formula during the experimental temperature rise test. Experimental results show that the proposed formula is highly accurate and has an acceptable correlation with the empirical values. The root-mean-square error, mean error, and average error percentage (AEP) of the proposed formula are 0.3?, 0.3 ?, and 0.37%, respectively, in HST transient values, and 0.3 ?, 0.3 ?, and 0.29% in HST steady-state values, which substantiate the precision and proficiency of the proposed HST prediction formula rather than IEC and IEEE equations. Finally, a thermal camera is employed to verify the results of CFD-based 3D modeling in top-oil temperature, bottom-oil temperature, and conservator oil temperature during the experimental tests. According to the measurement results, temperatures of CFD-based 3D simulation and thermal camera in the aforementioned three points are in good agreement with each other and AEP is less than 1.4%, which indicates the accuracy and efficiency of the proposed 3-D modeling.
引用
收藏
页码:7310 / 7322
页数:13
相关论文
共 50 条
  • [1] A review of temperature prediction methods for oil-immersed transformers
    Guo, Yi
    Chang, Yuan
    Lu, Bing
    MEASUREMENT, 2025, 239
  • [2] Experimental Studies on the Estimated Life of Oil-Immersed Insulation Paper in Traction Transformers
    Zhou, Lijun
    Liao, Wei
    Wang, Dongyang
    Cui, Yi
    Wang, Lujia
    Zhang, Liqing
    Guo, Lei
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (05) : 2646 - 2657
  • [3] A Novel Model for Thermal Behavior Prediction of Oil-Immersed Distribution Transformers With Consideration of Solar Radiation
    Taheri, Ali Asghar
    Abdali, Ali
    Rabiee, Abbas
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (04) : 1634 - 1646
  • [4] Review of Studies on the Hot Spot Temperature of Oil-Immersed Transformers
    Lin, Lin
    Qiang, Chengdan
    Zhang, Hui
    Chen, Qingguo
    An, Zhen
    Xu, Weijie
    ENERGIES, 2025, 18 (01)
  • [5] A Multivariable Sensing System for Condition Monitoring of Oil-Immersed Transformers
    Wani, Shufali Ashraf
    Sarathi, Ramanujam
    Subramanian, Venkatachalam
    IEEE SENSORS JOURNAL, 2025, 25 (06) : 9708 - 9717
  • [6] Distributed Thermal Circuit Model of Oil-immersed Distribution Transformers
    Ding Y.
    Zhang Q.
    Gao M.
    Li Y.
    Zhao Y.
    Yang H.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (03): : 968 - 974
  • [7] Lifetime Estimation and Optimal Maintenance Scheduling of Urban Oil-Immersed Distribution-Transformers Considering Weather-Dependent Intelligent Load Model and Unbalanced Loading
    Gorginpour, Hamed
    Ghimatgar, Hojat
    Toulabi, Mohammad Sedigh
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (05) : 4154 - 4165
  • [8] Research on temperature distribution characteristics of oil-immersed power transformers based on fluid network decoupling
    Xu, Yongming
    Xu, Ziyi
    Ren, Congrui
    Wang, Yaodong
    HIGH VOLTAGE, 2024, 9 (05): : 1136 - 1148
  • [9] Investigation of Electrostatic Charging Mechanism in Aged Oil-immersed Transformers
    Okabe, Shigemitsu
    Kohtoh, Masanori
    Amimoto, Tsuyoshi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (01) : 287 - 293
  • [10] Potential of Used Cooking Oil as Dielectric Liquid for Oil-Immersed Power Transformers
    Chairul, Imran Sutan
    Bakar, Norazhar Abu
    Othman, Md Nazri
    Ghani, Sharin Ab
    Khiar, Mohd Shahril Ahmad
    Talib, Mohd Aizam
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (04) : 1400 - 1407