Modeling and Simulation of DVR and D-STATCOM in Presence of Wind Energy System

被引:6
作者
Kamarposhti, Mehrdad Ahmadi [1 ]
Colak, Ilhami [2 ]
Thounthong, Phatiphat [3 ]
Eguchi, Kei [4 ]
机构
[1] Islamic Azad Univ, Dept Elect Engn, Jouybar Branch, Jouybar, Iran
[2] Nisantasi Univ, Fac Engn & Architectures, Dept Elect & Elect Engn, Istanbul, Turkiye
[3] King Mongkuts Univ Technol North Bangkok, Renewable Energy Res Ctr RERC, Dept Teacher Training Elect Engn, Fac Tech Educ, 1518,Pracharat 1 Rd, Bangkok 10800, Thailand
[4] Fukuoka Inst Technol, Dept Informat Elect, Fukuoka, Japan
来源
CMC-COMPUTERS MATERIALS & CONTINUA | 2023年 / 74卷 / 02期
关键词
Power quality; distribution system; DVR; D-STATCOM; wind turbine; PID CONTROLLER; POWER; GENERATION; ALGORITHM;
D O I
10.32604/cmc.2023.034082
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The present study suggests that series voltage injection is more effective than parallel current injection to improve voltage quality on the load side. The line voltage can be accurately symmetrized at the connection point by creating and controlling a series voltage component in each phase. This is more reliable and effective than parallel current injection. A dynamic voltage restorer (DVR) and a distribution static synchronous compensator (DSTATCOM) were utilized to provide the required power. The DVR is an effective andmodern device utilized in parallel within the grid and can protect sensitive loads from voltage problems in the grid by injecting voltage. The DVR and D-STATCOM were used to improve voltage stability in faults. A standard 13-bus system was studied in the presence of a wind farm. The simulation results demonstrated that single and three-phase overloads dramatically altered the voltage of the system, making it necessary to use compensators to improve voltage stability. The DVR and D-STATCOM showed similar performance under normal conditions and somewhat improved grid voltage unbalance. However, the DVR outperformed D-STATCOM under asymmetric faults conditions and led to lower voltage variations.
引用
收藏
页码:4547 / 4570
页数:24
相关论文
共 49 条
[1]   A new fast-converged estimation approach for Dynamic Voltage Restorer (DVR) to compensate voltage sags in waveform distortion conditions [J].
Abdollahzadeh, Hamed ;
Jazaeri, Mostafa ;
Tavighi, Arash .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 54 :598-609
[2]   Autonomous Appliance Scheduling for Household Energy Management [J].
Adika, Christopher O. ;
Wang, Lingfeng .
IEEE TRANSACTIONS ON SMART GRID, 2014, 5 (02) :673-682
[3]   Power quality improvement using STS and DVR in wind energy system [J].
Agalar, Sener ;
Kaplan, Yusuf Alper .
RENEWABLE ENERGY, 2018, 118 :1031-1040
[4]   Improving fault ride-through capability of wind generation system using DVR [J].
Amutha, N. ;
Kumar, B. Kalyan .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 46 :326-333
[5]  
Cai T., 2022, MATHEMATICS-BASEL, V10, P1
[6]   Uncertainty-Aware Household Appliance Scheduling Considering Dynamic Electricity Pricing in Smart Home [J].
Chen, Xiaodao ;
Wei, Tongquan ;
Hu, Shiyan .
IEEE TRANSACTIONS ON SMART GRID, 2013, 4 (02) :932-941
[7]   Spatiotemporal characteristics and attribution of dry/wet conditions in the Weihe River Basin within a typical monsoon transition zone of East Asia over the recent 547 years [J].
Chen, Xinyu ;
Quan, Quan ;
Zhang, Ke ;
Wei, Jiahua .
ENVIRONMENTAL MODELLING & SOFTWARE, 2021, 143 (143)
[8]  
El-Gammal M. A., 2015, INT J ELECT ENG INFO, V3, P1
[9]  
Ferdi B., 2010, Journal of Electrical Engineering: Theory and Application, V1, P165
[10]   Energy-Efficient Buildings Facilitated by Microgrid [J].
Guan, Xiaohong ;
Xu, Zhanbo ;
Jia, Qing-Shan .
IEEE TRANSACTIONS ON SMART GRID, 2010, 1 (03) :243-252