Microextraction by packed sorbent of synthetic tryptamines from urine and ion mobility spectrometry determination

被引:4
|
作者
Aparici-Lozano, Maria [1 ]
Armenta, Sergio [1 ]
Garrigues, Salvador [1 ]
Esteve-Turrillas, Francesc A. [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, Jeronimo Munoz Bldg 50th Dr Moliner St, Burjassot 46100, Spain
来源
关键词
New psychoactive substances; Tryptamines; Urine; Microextraction by packed sorbent; Ion mobility spectrometry; Green analytical chemistry; DAMAGE DETECTION; PSYCHOACTIVE SUBSTANCES; CRACK DETECTION; IDENTIFICATION; OPTIMIZATION; FREQUENCY; BEAMS; BLOOD; MS/MS;
D O I
10.1016/j.sampre.2023.100055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure for the determination of N,N-dipropyltryptamine, 5 -methoxy-N,N-dimethyltryptamine, and 5 -methoxy-N-methyl-N-isopropyltryptamine in urine has been developed based on a microextraction by packed sorbent (MEPS) followed by ion mobility spectrometry determination. The combination of microextraction by packed sorbent with ion mobility spectrometry provided promising advantages for in-field screening of new psy-choactive substances in urine, due to its simplicity, automation, and portability. The effect of sample pH and ionic strength, and the number of loading and elution steps has been evaluated. The obtained limits of quantification ranged from 21 to 29 mu g L-1, and accuracy and precision were evaluated by the determination of blank urine samples spiked at limits of quantification, 250, and 500 mu g L-1 synthetic tryptamines, with recovery values in the range of 76-95% and relative standard deviations lower than 20%. Moreover, the environmental impact and greenness of the proposed extraction method has been evaluated, providing an AGREEprep score of 0.62. Thus, the developed methodology can be considered a reliable and green screening methodology for in-field abuse drug consumption detection.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Methylone determination in oral fluid using microextraction by packed sorbent coupled to ion mobility spectrometry
    Sorribes-Soriano, A.
    Sanchez-Martinez, S.
    Arraez-Gonzalez, R.
    Esteve-Turrillas, F. A.
    Armenta, S.
    MICROCHEMICAL JOURNAL, 2020, 153
  • [2] Determination of the new psychoactive substance dichloropane in saliva by microextraction by packed sorbent - Ion mobility spectrometry
    Sorribes-Soriano, Aitor
    Monedero, Amparo
    Esteve-Turrillas, Francesc A.
    Armenta, Sergio
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1603 : 61 - 66
  • [3] The Determination of Cannabinoids in Urine Samples Using Microextraction by Packed Sorbent and Gas Chromatography-Mass Spectrometry
    Rosendo, Luana M.
    Rosado, Tiago
    Oliveira, Patrik
    Simao, Ana Y.
    Margalho, Claudia
    Costa, Suzel
    Passarinha, Luis A.
    Barroso, Mario
    Gallardo, Eugenia
    MOLECULES, 2022, 27 (17):
  • [4] Determination of synthetic hallucinogens in oral fluids by microextraction by packed sorbent and liquid chromatography–tandem mass spectrometry
    Evan Lesne
    Miguel Muñoz-Bartual
    Francesc A. Esteve-Turrillas
    Analytical and Bioanalytical Chemistry, 2023, 415 : 3607 - 3617
  • [5] Determination of synthetic hallucinogens in oral fluids by microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry
    Lesne, Evan
    Munoz-Bartual, Miguel
    Esteve-Turrillas, Francesc A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (17) : 3607 - 3617
  • [6] Miniaturized extraction method for analysis of synthetic opioids in urine by microextraction with packed sorbent and liquid chromatography-tandem mass spectrometry
    da Cunha, Kelly Francisco
    Rodrigues, Leonardo Costalonga
    Huestis, Marilyn A.
    Costa, Jose Luiz
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1624
  • [7] Microextraction by packed sorbent coupled with gas chromatography—mass spectrometry: application to the determination of metabolites of monoterpenes in small volumes of human urine
    Silke Matysik
    Frank-Michael Matysik
    Microchimica Acta, 2009, 166 : 109 - 114
  • [8] Determination of amphetamine-type stimulants in urine samples using microextraction by packed sorbent and gas chromatography-mass spectrometry
    Malaca, Sara
    Rosado, Tiago
    Restolho, Jose
    Rodilla, Jesus M.
    Rocha, Pedro M. M.
    Silva, Lucia
    Margalho, Claudia
    Barroso, Mario
    Gallardo, Eugenia
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1120 : 41 - 50
  • [9] Sorbent-packed needle microextraction trap for synthetic musks determination in wastewater samples
    Vallecillos, Laura
    Borrull, Francesc
    Sanchez, Juan M.
    Pocurull, Eva
    TALANTA, 2015, 132 : 548 - 556
  • [10] Sol-gel/nanoclay composite as a sorbent for microextraction in packed syringe combined with corona discharge ionization ion mobility spectrometry for the determination of diazinon in water samples
    Saraji, Mohammad
    Jafari, Mohammad Taghi
    Amooshahi, Mohammad Mehdi
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (02) : 493 - 500