Experimental Study of an Air-Conditioning System in an Electric Vehicle with R1234yf

被引:2
作者
Song, Jeonghyun [1 ]
Eom, Seongyong [1 ]
Lee, Jaeseung [2 ]
Chu, Youngshin [2 ]
Kim, Jaewon [2 ]
Choi, Seohyun [2 ]
Choi, Minsung [3 ]
Choi, Gyungmin [1 ]
Park, Yeseul [4 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
[2] KORENS, R&D Div, Yangsan 50591, South Korea
[3] Gangneung Wonju Natl Univ, Dept Automot Engn, Wonju 26403, South Korea
[4] Pusan Natl Univ, Sch Convergence Sci, Busan 46241, South Korea
基金
新加坡国家研究基金会;
关键词
automotive heat pump; R1234yf; electric vehicle; empirical test; performance analysis; HEAT-PUMP SYSTEM; PERFORMANCE EVALUATION; REPLACEMENT; R134A;
D O I
10.3390/en16248017
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
R134a, a vehicle refrigerant used in the vehicle heat pump system, is regulated according to the Montreal Protocol. Refrigerants such as R1234yf, R744, and R290 in vehicle heat pump systems are being investigated to identify their alternatives. Because developing a new system exclusively for new refrigerants is costly, an empirical test was conducted on the R1234yf refrigerant in a heat pump system designed for the R134a refrigerant in an actual vehicle system. The heating, cooling, and battery-cooling modes were tested for the amount of refrigerant charge, and operability tests were conducted for the compressor load; heating, ventilation, air conditioning (HVAC) air flow rate; coolant temperature; and flow rate of each mode. The optimal refrigerant charge in heating mode was 0.7 kg, and the optimal refrigerant charge in the cooling and battery-cooling modes was 0.9 kg. To yield the highest coefficient of performance of the system, the compressor load was 50%, the HVAC fan was 12 V, and the coolant flow rate was 10 LPM. The most efficient system operation was possible at a coolant temperature of 30 degrees C in the cooling and heating modes and at 20 degrees C in battery-cooling mode.
引用
收藏
页数:13
相关论文
共 21 条
[1]  
[Anonymous], Amendment to the Montreal Protocol on Substances That Deplete the Ozone Layer
[2]  
[Anonymous], 2021, INT ENERGY AGENCY, P224
[3]  
Direk M., 2017, Therm. Sci
[4]   Experimental Evaluation of an Automotive Heat Pump System with R1234yf as an Alternative to R134a [J].
Direk, Mehmet ;
Yuksel, Fikret .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (02) :719-728
[5]   AUTOMOTIVE AIR CONDITIONING SYSTEM WITH AN INTERNAL HEAT EXCHANGER USING R1234YF AND DIFFERENT EVAPORATION AND CONDENSATION TEMPERATURES [J].
Direk, Mehmet ;
Kelesoglu, Alper .
THERMAL SCIENCE, 2019, 23 (02) :1115-1125
[6]   Drop-in Performance Analysis and Effect of IHX for an Automotive Air Conditioning System with R1234yf as a Replacement of R134a [J].
Direk, Mehmet ;
Kelesoglu, Alper ;
Akin, Ahmet .
STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2017, 63 (05) :314-319
[7]   COMPARATIVE PERFORMANCE ANALYSIS OF EXPERIMENTAL FRIGORIFIC AIR CONDITIONING SYSTEM USING R-134A AND HFO-1234YF AS A REFRIGERANT [J].
Direk, Mehmet ;
Tunckal, Cuneyt ;
Yuksel, Fikret .
THERMAL SCIENCE, 2016, 20 (06) :2065-2072
[8]  
Kim Ki Bum, 2013, [Journal of Korea Academia-Industrial cooperation Society, 한국산학기술학회논문지], V14, P4679, DOI 10.5762/KAIS.2013.14.10.4679
[9]  
Kopec P., 2015, Czas. Tech
[10]   Performance evaluation of a vapor injection heat pump system for electric vehicles [J].
Kwon, Chunkyu ;
Kim, Mo Se ;
Choi, Younguk ;
Kim, Min Soo .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 74 :138-150