Seismic Design and Performance Evaluation of Coupled Steel Plate and Reinforced Concrete Composite Walls

被引:1
作者
Liu, Aozhou [1 ]
Wu, Yuntian [2 ]
Wang, Bin [1 ]
Chen, Xiyue [1 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Univ Houston, Dept Civil & Environm Engn, Houston, TX 77204 USA
基金
中国国家自然科学基金;
关键词
steel plate; composite shear wall; coupled wall; energy balance; plastic design; coupling ratio; ENERGY;
D O I
10.3390/buildings13092242
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Coupled steel plate and reinforced concrete (SPRC) composite shear walls have been widely constructed in the core tube of super tall buildings in seismic regions. However, relevant research progress is far behind the practical application of this coupled composite wall system. Particularly, the current seismic design method does not consider the coupling mechanism and lacks efficiency in the computation of seismic base shear. In this research, the energy balance-based plastic design (EBPD) method is developed and used to design twelve prototype structures considering different structural heights and coupling ratios (CR). With the ABAQUS-based numerical techniques verified by relevant experimental results, all the prototype cases were studied by pushover analysis and nonlinear dynamic analysis to examine the effectiveness of the EBPD method in ensuring satisfactory seismic performance of coupled SPRC composite walls. The results indicate that the coupled SPRC composite walls designed by the EBPD method can satisfy the code requirements on lateral deformation under moderate and rare earthquakes. The analytical average story shear and bending moment distribution patterns have acceptable agreement with the relevant design assumptions. Favorable CR ranges are suggested for the coupled SPRC composite walls with different story numbers to achieve good earthquake-induced deformation characteristics.
引用
收藏
页数:24
相关论文
共 23 条
[1]  
[Anonymous], 2005, EN 1993-1-2:2005
[2]  
[Anonymous], 2010, GB 50011-2010
[3]  
[Anonymous], 2016, JGJ138
[4]  
[Anonymous], 2014, DESIGN CONCRETE STRU
[5]   Assessing and quantifying the earthquake response of reinforced concrete buckling-restrained brace frame structures [J].
Bai, Jiulin ;
Cheng, Feng ;
Jin, Shuangshuang ;
Ou, Jinping .
BULLETIN OF EARTHQUAKE ENGINEERING, 2019, 17 (07) :3847-3871
[6]   Improved Performance-Based Plastic Design for RC Moment Resisting Frames: Development and a Comparative Case Study [J].
Bai, Jiulin ;
Yang, T. Y. ;
Ou, Jinping .
INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2018, 18 (04)
[7]   Capacity Design of Coupled Composite Plate Shear Wall-Concrete-Filled System [J].
Broberg, Morgan ;
Shafaei, Soheil ;
Kizilarslan, Emre ;
Seo, Jungil ;
Varma, Amit H. ;
Bruneau, Michel ;
Klemencic, Ron .
JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (04)
[8]   Performance-based plastic design method for tall hybrid coupled walls [J].
Chan-Anan, Watchara ;
Leelataviwat, Sutat ;
Goel, Subhash C. .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2016, 25 (14) :681-699
[9]  
Chao S.H., 2006, P 4 INT C EARTHQ ENG
[10]   A seismic design lateral force distribution based on inelastic state of structures [J].
Chao, Shih-Ho ;
Goel, Subhash C. ;
Lee, Soon-Sik .
EARTHQUAKE SPECTRA, 2007, 23 (03) :547-569