Does intraoperative fluoroscopy improve acetabular component positioning and limb-length discrepancy during direct anterior total hip arthroplasty? A meta-analysis

被引:3
|
作者
Sun, Changjiao [1 ]
Lee, Woo Guan [2 ]
Ma, Qi [1 ]
Zhang, Xiaofei [3 ]
Zhao, Zhe [1 ]
Cai, Xu [1 ]
机构
[1] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Sch Clin Med, Dept Orthoped, 168 Litang Rd, Beijing 102218, Peoples R China
[2] FRCS Edinburgh Kuching Specialist Hosp Sarawak, Tabuan Stutong Commercial Ctr, Kuching Sarawak 93350, Malaysia
[3] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Sch Clin Med, Dept Clin Epidemiol & Biostat, 168 Litang Rd, Beijing 102218, Peoples R China
关键词
Total hip arthroplasty; Intraoperative fluoroscopy; Component positioning; Limb-length discrepancy; RADIATION-EXPOSURE; DISLOCATION; RISK;
D O I
10.1186/s13018-023-04023-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe positioning of implant components for total hip arthroplasty (THA) is essential for joint stability, polyethylene liner wear, and range of motion. One potential benefit of the direct anterior approach (DAA) for THA is the ability to use intraoperative fluoroscopy for acetabular cup positioning and limb-length evaluation. Previous studies comparing intraoperative fluoroscopy with no fluoroscopy during DAA have reported conflicting results. This meta-analysis aimed to evaluate whether intraoperative fluoroscopy improves component positioning compared to no fluoroscopy during direct anterior total hip arthroplasty.MethodsA systematic review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was conducted. We searched Web of Science, EMBASE, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database in May 2023 to identify studies involving intraoperative fluoroscopy versus no fluoroscopy during direct anterior total hip arthroplasty. Finally, we identified 1262 hips assessed in seven studies.ResultsThere were no significant differences in terms of acetabular cup inclination angle (ACIA, P = 0.21), ACIA within safe zone rate (P = 0.97), acetabular cup anteversion angle (ACAA, P = 0.26); ACAA within safe zone rate (P = 0.07), combined safe zone rate (P = 0.33), and limb-length discrepancy (LLD, P = 0.21) between two groups.ConclusionEven though intraoperative fluoroscopy was not related to an improvement in cup location or LDD. With fewer experienced surgeons, the benefit of intraoperative fluoroscopy might become more evident. More adequately powered and well-designed long-term follow-up studies were required to determine whether the application of the intraoperative fluoroscopy for direct anterior total hip arthroplasty will have clinical benefits and improve the survival of prostheses.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Does intraoperative fluoroscopy improve acetabular component positioning and limb-length discrepancy during direct anterior total hip arthroplasty? A meta-analysis
    Changjiao Sun
    Woo Guan Lee
    Qi Ma
    Xiaofei Zhang
    Zhe Zhao
    Xu Cai
    Journal of Orthopaedic Surgery and Research, 18
  • [2] Does Intraoperative Fluoroscopy Improve Limb-Length Discrepancy and Acetabular Component Positioning During Direct Anterior Total Hip Arthroplasty?
    Bingham, Joshua S.
    Spangehl, Mark J.
    Hines, Jeremy T.
    Taunton, Michael J.
    Schwartz, Adam J.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (09): : 2927 - 2931
  • [3] Does Intraoperative Fluoroscopy Improve Component Positioning in Total Hip Arthroplasty?
    Rathod, Parthiv A.
    Deshmukh, Ajit J.
    Rodriguez, Jose A.
    ORTHOPEDICS, 2016, 39 (02) : 71 - 71
  • [4] Does Intraoperative Fluoroscopy Improve Component Positioning in Total Hip Arthroplasty?
    Tischler, Eric H.
    Orozco, Fabio
    Aggarwal, Vinay K.
    Pacheco, Haroldo
    Post, Zachary
    Ong, Alvin
    ORTHOPEDICS, 2015, 38 (01) : E1 - E6
  • [5] The effect of intraoperative fluoroscopy on acetabular component positioning and patient anatomy restoration during total hip arthroplasty: A systematic review and meta-analysis
    Sun, Changjiao
    Gao, Hong
    Ma, Qi
    Li, Huimin
    Zhang, Xiaofei
    Cai, Xu
    MEDICINE, 2024, 103 (37)
  • [6] Does Fluoroscopy Improve Acetabular Component Placement in Total Hip Arthroplasty?
    Beamer, Brandon S.
    Morgan, Jordan H.
    Barr, Christopher
    Weaver, Michael J.
    Vrahas, Mark S.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (12) : 3953 - 3962
  • [7] The effect of intraoperative fluoroscopy on acetabular component positioning and patient anatomy restoration during posterior or posterolateral approach total hip arthroplasty: a meta-analysis
    Sun, Changjiao
    Lee, Woo Guan
    Ma, Qi
    Zhang, Xiaofei
    Song, Fei
    Cai, Xu
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (04) : 1781 - 1792
  • [8] The effect of intraoperative fluoroscopy on acetabular component positioning and patient anatomy restoration during posterior or posterolateral approach total hip arthroplasty: a meta-analysis
    Changjiao Sun
    Woo Guan Lee
    Qi Ma
    Xiaofei Zhang
    Fei Song
    Xu Cai
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 1781 - 1792
  • [9] Are We Being Fooled by Fluoroscopy? Distortion May Affect Limb-Length Measurements in Direct Anterior Total Hip Arthroplasty
    Carlson, Victor R.
    Elliott, Iain S.
    DeKeyser, Graham J.
    Pelt, Christopher E.
    Anderson, Lucas A.
    Gililland, Jeremy M.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (05): : 1799 - 1803
  • [10] Accuracy of Fluoroscopic Guided Acetabular Component Positioning During Direct Anterior Total Hip Arthroplasty
    Slotkin, Eric M.
    Patel, Preetesh D.
    Suarez, Juan C.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (09): : 102 - 106