An Improved Design of the MultiCal On-Site Calibration Device for Industrial Robots

被引:4
作者
Wan, Ziwei [1 ,2 ]
Zhou, Chunlin [1 ]
Lin, Zhaohui [3 ]
Yan, Huapeng [4 ]
Tang, Weixi [1 ]
Wang, Zhen [5 ]
Wu, Jun [1 ]
机构
[1] Zhejiang Univ, Coll Control Sci & Engn, Hangzhou 310063, Peoples R China
[2] Zhejiang Univ, Huzhou Inst, Lab Med Robots, Huzhou 313098, Peoples R China
[3] Zhejiang Univ, Sch Mech Engn, Hangzhou 310030, Peoples R China
[4] Univ Elect Sci & Technol China, Sch Automation Engn, Chengdu 611731, Peoples R China
[5] Huzhou Univ, Sch Engn, Huzhou 313000, Peoples R China
基金
中国国家自然科学基金;
关键词
calibration device; kinematic calibration; on-site calibration; industrial robot; accuracy measurement; KINEMATIC CALIBRATION;
D O I
10.3390/s23125717
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
MultiCal is an affordable, high-precision measuring device designed for the on-site calibration of industrial robots. Its design features a long measuring rod with a spherical tip that is attached to the robot. By restricting the rod's tip to multiple fixed points under different rod orientations, the relative positions of these points are accurately measured beforehand. A common issue with MultiCal is the gravity deformation of the long measuring rod, which introduces measurement errors into the system. This problem becomes especially serious when calibrating large robots, as the length of the measuring rod needs to be increased to enable the robot to move in a sufficient space. To address this issue, we propose two improvements in this paper. Firstly, we suggest the use of a new design of the measuring rod that is lightweight yet has high rigidity. Secondly, we propose a deformation compensation algorithm. Experimental results have shown that the new measuring rod improves calibration accuracy by 20% to 39%, while by using the deformation compensation algorithm, the accuracy increases by 6% to 16%. In the best configuration, the calibration accuracy is similar to that of a measuring arm with a laser scanner, producing an average positioning error of 0.274 mm and a maximum positioning error of 0.838 mm. The improved design is cost-affordable, robust, and has sufficient accuracy, making MultiCal a more reliable tool for industrial robot calibration.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Research on Modular Design of Perpendicular Jointed Industrial Robots
    Song, Lin
    Yang, Suixian
    INTELLIGENT ROBOTICS AND APPLICATIONS, PT I: ICIRA 2011, 2011, 7101 : 63 - 72
  • [42] The Research of Industrial Robots Design Based on Synchronous Technology
    Wang, Xuejun
    Chi, Yilin
    Li, Fuyu
    Gao, Li
    Peng, Yongxin
    FLUID DYNAMIC AND MECHANICAL & ELECTRICAL CONTROL ENGINEERING, 2012, 233 : 347 - +
  • [43] Knowledge-based functional design of industrial robots
    Tor, S. B.
    Lee, S. G.
    Britton, G. A.
    Zhang, W. Y.
    INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2008, 46 (16) : 4501 - 4519
  • [44] Position Calibration Method for Large size Industrial Robots Based on Random Forest
    Kato, D.
    Maeda, N.
    Hirogaki, T.
    Aoyama, E.
    Takahashi, K.
    2021 21ST INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2021), 2021, : 607 - 612
  • [45] Compensation of Trajectory Error for Industrial Robots by Interpolation and Calibration Method in the Joint Space
    Gao G.
    Zhang S.
    Na J.
    Liu F.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2021, 57 (21): : 55 - 67
  • [46] Hierarchical calibration method of industrial robots based on PSO-SVR algorithm
    Xue X.
    Zhang C.
    Hu T.
    Chen Q.
    Ding X.
    Jisuanji Jicheng Zhizao Xitong/Computer Integrated Manufacturing Systems, CIMS, 2023, 29 (01): : 51 - 60
  • [47] A fast on-site calibration method designed based on hierarchical coupled discrete mathematical model
    Wang Zemin
    Xie Mengtao
    Lei Zhiyong
    Gao Junchai
    JOURNAL OF DIFFERENCE EQUATIONS AND APPLICATIONS, 2017, 23 (1-2) : 429 - 442
  • [48] A Two-Step Self-calibration Method with Portable Measurement Devices for Industrial Robots Based on POE Formula
    Gu, Lefeng
    Yang, Guilin
    Fang, Zaojun
    Shen, Wenjun
    Zheng, Tianjiang
    Chen, Chinyin
    Zhang, Chi
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2019, PT I, 2019, 11740 : 715 - 727
  • [49] A Comprehensive On-Load Calibration Method for Industrial Robots Based on a Unified Kinetostatic Error Model and Gaussian Process Regression
    Zhou, Yaohua
    Chen, Chin-Yin
    Tang, Ye
    Wan, Hongyu
    Luo, Jingbo
    Yang, Guilin
    Zhang, Chi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 11
  • [50] Study of Neural-Kinematics Architectures for Model-Less Calibration of Industrial Robots
    Tiboni, Monica
    Legnani, Giovanni
    Pellegrini, Nicola
    JOURNAL OF ROBOTICS AND MECHATRONICS, 2021, 33 (01) : 158 - 171