An Improved Design of the MultiCal On-Site Calibration Device for Industrial Robots

被引:4
作者
Wan, Ziwei [1 ,2 ]
Zhou, Chunlin [1 ]
Lin, Zhaohui [3 ]
Yan, Huapeng [4 ]
Tang, Weixi [1 ]
Wang, Zhen [5 ]
Wu, Jun [1 ]
机构
[1] Zhejiang Univ, Coll Control Sci & Engn, Hangzhou 310063, Peoples R China
[2] Zhejiang Univ, Huzhou Inst, Lab Med Robots, Huzhou 313098, Peoples R China
[3] Zhejiang Univ, Sch Mech Engn, Hangzhou 310030, Peoples R China
[4] Univ Elect Sci & Technol China, Sch Automation Engn, Chengdu 611731, Peoples R China
[5] Huzhou Univ, Sch Engn, Huzhou 313000, Peoples R China
基金
中国国家自然科学基金;
关键词
calibration device; kinematic calibration; on-site calibration; industrial robot; accuracy measurement; KINEMATIC CALIBRATION;
D O I
10.3390/s23125717
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
MultiCal is an affordable, high-precision measuring device designed for the on-site calibration of industrial robots. Its design features a long measuring rod with a spherical tip that is attached to the robot. By restricting the rod's tip to multiple fixed points under different rod orientations, the relative positions of these points are accurately measured beforehand. A common issue with MultiCal is the gravity deformation of the long measuring rod, which introduces measurement errors into the system. This problem becomes especially serious when calibrating large robots, as the length of the measuring rod needs to be increased to enable the robot to move in a sufficient space. To address this issue, we propose two improvements in this paper. Firstly, we suggest the use of a new design of the measuring rod that is lightweight yet has high rigidity. Secondly, we propose a deformation compensation algorithm. Experimental results have shown that the new measuring rod improves calibration accuracy by 20% to 39%, while by using the deformation compensation algorithm, the accuracy increases by 6% to 16%. In the best configuration, the calibration accuracy is similar to that of a measuring arm with a laser scanner, producing an average positioning error of 0.274 mm and a maximum positioning error of 0.838 mm. The improved design is cost-affordable, robust, and has sufficient accuracy, making MultiCal a more reliable tool for industrial robot calibration.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Contribution to Uncertainty Propagation Associated with On-Site Calibration of Infrasound Monitoring Systems
    Demeyer, Severine
    Kristoffersen, Samuel K.
    Le Pichon, Alexis
    Larsonnier, Franck
    Fischer, Nicolas
    REMOTE SENSING, 2023, 15 (07)
  • [32] Critical technology of on-site calibration system for DC electronic instrument transformer
    Zhang J.
    Hu Y.
    Liu F.
    Yao X.
    Yao J.
    Gaodianya Jishu/High Voltage Engineering, 2016, 42 (09): : 3003 - 3010
  • [33] The Study of HVDC Current Transformer on Operational Status and On-site Calibration Technology
    Zhang, Dingqu
    Pan, Feng
    Lin, Guoying
    Xiao, Yong
    INTERNATIONAL CONFERENCE ON NEW ENERGY AND RENEWABLE RESOURCES (ICNERR 2015), 2015, : 53 - 63
  • [34] A novel method to enhance the accuracy of parameter identification in elasto-geometrical calibration for industrial robots
    Yu, Shihang
    Nan, Jie
    Sun, Yuwen
    ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2024, 90
  • [35] Full pose measurement system for industrial robots kinematic calibration based on a sensorized spatial linkage mechanism
    Tiboni, Monica
    Legnani, Giovanni
    Bussola, Roberto
    Tosi, Diego
    MECHANISM AND MACHINE THEORY, 2024, 197
  • [36] Study on On-Site Calibration Technology for Fixed Ambient Dose Equivalent Radiation Ratemeters
    Gao F.
    Xu Y.
    Xiao X.
    Ni N.
    Hou J.
    2018, Atomic Energy Press (39): : 111 - 115
  • [37] An On-site calibration method for on-line detection system of wheelset geometric parameters
    Tu, YiMeng
    He, Qixin
    Ran, Yunfeng
    Feng, Qibo
    2019 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2020, 11439
  • [38] A Novel Multifeature Based On-Site Calibration Method for LiDAR-IMU System
    Liu, Wanli
    Li, Zhixiong
    Malekian, Reza
    Angel Sotelo, Miguel
    Ma, Zhenjun
    Li, Weihua
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (11) : 9851 - 9861
  • [39] Multiple Natural Features Fusion for On-Site Calibration of LiDAR Boresight Angle Misalignment
    Liu, Wanli
    Gardoni, Paolo
    Li, Zhixiong
    Krolczyk, Grzegorz M.
    Du, Haiping
    Li, Weihua
    Sotelo, Miguel Angel
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [40] On-site transient performance calibration of DC current transformer for HVDC transmission project
    Pang F.
    Liu Y.
    Ji J.
    Bu Q.
    Zhang C.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (14): : 179 - 187