An Improved Design of the MultiCal On-Site Calibration Device for Industrial Robots

被引:4
|
作者
Wan, Ziwei [1 ,2 ]
Zhou, Chunlin [1 ]
Lin, Zhaohui [3 ]
Yan, Huapeng [4 ]
Tang, Weixi [1 ]
Wang, Zhen [5 ]
Wu, Jun [1 ]
机构
[1] Zhejiang Univ, Coll Control Sci & Engn, Hangzhou 310063, Peoples R China
[2] Zhejiang Univ, Huzhou Inst, Lab Med Robots, Huzhou 313098, Peoples R China
[3] Zhejiang Univ, Sch Mech Engn, Hangzhou 310030, Peoples R China
[4] Univ Elect Sci & Technol China, Sch Automation Engn, Chengdu 611731, Peoples R China
[5] Huzhou Univ, Sch Engn, Huzhou 313000, Peoples R China
基金
中国国家自然科学基金;
关键词
calibration device; kinematic calibration; on-site calibration; industrial robot; accuracy measurement; KINEMATIC CALIBRATION;
D O I
10.3390/s23125717
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
MultiCal is an affordable, high-precision measuring device designed for the on-site calibration of industrial robots. Its design features a long measuring rod with a spherical tip that is attached to the robot. By restricting the rod's tip to multiple fixed points under different rod orientations, the relative positions of these points are accurately measured beforehand. A common issue with MultiCal is the gravity deformation of the long measuring rod, which introduces measurement errors into the system. This problem becomes especially serious when calibrating large robots, as the length of the measuring rod needs to be increased to enable the robot to move in a sufficient space. To address this issue, we propose two improvements in this paper. Firstly, we suggest the use of a new design of the measuring rod that is lightweight yet has high rigidity. Secondly, we propose a deformation compensation algorithm. Experimental results have shown that the new measuring rod improves calibration accuracy by 20% to 39%, while by using the deformation compensation algorithm, the accuracy increases by 6% to 16%. In the best configuration, the calibration accuracy is similar to that of a measuring arm with a laser scanner, producing an average positioning error of 0.274 mm and a maximum positioning error of 0.838 mm. The improved design is cost-affordable, robust, and has sufficient accuracy, making MultiCal a more reliable tool for industrial robot calibration.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] A fast calibration method of the tool frame for industrial robots
    Jiang, Lichen
    Gao, Guanbin
    Na, Jing
    Xing, Yashan
    2023 IEEE 12TH DATA DRIVEN CONTROL AND LEARNING SYSTEMS CONFERENCE, DDCLS, 2023, : 875 - 880
  • [22] POE-Based Parameter Calibration for Industrial Robots Considering Joint Compliance
    Luo, Ruiqing
    Gao, Wenbin
    Huang, Qi
    2021 5TH INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION SCIENCES (ICRAS 2021), 2021, : 15 - 22
  • [23] On-site calibration method of the AACMM based on a high-precision CNC machine tool
    Wang, Wen
    Sun, Jiahuan
    Sun, Tao
    Lu, Keqing
    Yang, He
    Chen, Zhanfeng
    Wang, Chuanyong
    Weng, Yixin
    Cui, Xueguang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (11)
  • [24] Improved subspace modal identification of industrial robots
    Qiao, Yuting
    Cao, Junyi
    Huang, Guohui
    Liu, Huan
    Lei, Yaguo
    Liu, Qinghua
    JOURNAL OF FIELD ROBOTICS, 2023, 40 (06) : 1327 - 1338
  • [25] An on-site approach for the self-calibration of terrestrial laser scanner
    Abbas, Mohd Azwan
    Lichti, Derek D.
    Chong, Albert K.
    Setan, Halim
    Majid, Zulkepli
    MEASUREMENT, 2014, 52 : 111 - 123
  • [26] On-Site Calibration Procedure and Uncertainty Contributions on Air Temperature Sensors
    Aranda, Natali Giselle
    Merlone, Andrea
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2024, 45 (01)
  • [27] On-site Metrology Calibration Method for River-piping Flowmeter
    Wang, Li
    Wang, Cheng
    Yang, Fei
    CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE II, PTS 1 AND 2, 2013, 438-439 : 1294 - 1298
  • [28] On-Site Calibration Procedure and Uncertainty Contributions on Air Temperature Sensors
    Natali Giselle Aranda
    Andrea Merlone
    International Journal of Thermophysics, 2024, 45
  • [29] Positioning Error Calibration of Industrial Robots Based on Random Forest
    Kato, Daiki
    Yoshitsugu, Kenya
    Maeda, Naoki
    Hirogaki, Toshiki
    Aoyama, Eiichi
    Takahashi, Kenichi
    INTERNATIONAL JOURNAL OF AUTOMATION TECHNOLOGY, 2021, 15 (05) : 581 - 589
  • [30] The Kinematic Calibration of an Industrial Robot With an Improved Beetle Swarm Optimization Algorithm
    Chen, Xiangzhen
    Zhan, Qiang
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2022, 7 (02) : 4694 - 4701