Negative-Sequence Current Compensation-Based Coordinated Control Strategy for Dual-Cage-Rotor Brushless Doubly Fed Induction Generator Under Unbalanced Grid Conditions

被引:6
作者
Cheng, Ming [1 ]
Yan, Xiaoming [1 ]
Zhou, Jiawei [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
Rotors; Voltage control; Doubly fed induction generators; PI control; Reactive power; Wind turbines; Voltage; Brushless doubly fed induction generator (BDFIG); coordinated control; negative-sequence current compensation; unbalanced grid voltage;
D O I
10.1109/TIE.2022.3186317
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this article, we propose a negative-sequence current compensation-based coordinated control strategy for dual-cage-rotor brushless doubly fed induction generator, where the machine-side converter (MSC) and the grid-side converter (GSC) cooperate to mitigate the imbalance in the control winding current, total output power, and total grid current. Based on the machine dynamic model withstanding unbalanced grid voltage, the negative-sequence current references, including four targets for MSC and three targets for GSC, are calculated and sent to the inner-current-loop controllers, where the GSC current controller is designed based on the supertwisting sliding-mode control with the stability analyzed. This proposed control strategy omits the outer-loop controller in the negative-sequence frame, which has a more simple control structure and becomes more easy-implemented. Finally, the whole proposed coordinated control system is designed and implemented in both simulation and experiments under unbalanced grid conditions, verifying the effectiveness of the proposed control strategy.
引用
收藏
页码:4762 / 4773
页数:12
相关论文
共 29 条
[1]  
Abad G., 2011, DOUBLY FED INDUCTION, DOI [10.1002/9781118104965, DOI 10.1002/9781118104965]
[2]  
[Anonymous], 2021, Global Solar Council, P2021, DOI [10.1787/39351842-en, DOI 10.1787/39351842-EN]
[3]  
Barrena JA, 2006, IEEE IND ELEC, P1773
[4]   Reduced-Order State Observer-Based Feedback Control Methodologies for Doubly Fed Induction Machine [J].
Bhattarai, Rojan ;
Gurung, Niroj ;
Thakallapelli, Abilash ;
Kamalasadan, Sukumar .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (03) :2845-2856
[5]  
Bollen M. H. J., 2002, IEEE Power Engineering Review, V22, P49, DOI 10.1109/MPER.2002.1045567
[6]   Implementation of Super-Twisting Control: Super-Twisting and Higher Order Sliding-Mode Observer-Based Approaches [J].
Chalanga, Asif ;
Kamal, Shyam ;
Fridman, Leonid M. ;
Bandyopadhyay, Bijnan ;
Moreno, Jaime A. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (06) :3677-3685
[7]   Improved Vector Control of Brushless Doubly Fed Induction Generator under Unbalanced Grid Conditions for Offshore Wind Power Generation [J].
Chen, Jiansheng ;
Zhang, Wei ;
Chen, Bojian ;
Ma, Yunlong .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (01) :293-302
[8]   Unbalanced and Low-Order Harmonic Voltage Mitigation of Stand-Alone Dual-Stator Brushless Doubly Fed Induction Wind Generator [J].
Cheng, Ming ;
Jiang, Yunlei ;
Han, Peng ;
Wang, Qingsong .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (11) :9135-9146
[9]   The state of the art of wind energy conversion systems and technologies: A review [J].
Cheng, Ming ;
Zhu, Ying .
ENERGY CONVERSION AND MANAGEMENT, 2014, 88 :332-347
[10]   Indirect Torque Control of a Cascaded Brushless Doubly-Fed Induction Generator Operating With Unbalanced Power Grid [J].
Dauksha, Gennadiy ;
Iwanski, Grzegorz .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2020, 35 (02) :1065-1077