Smart Glasses to Facilitate Ultrasound Guided Peripheral Intravenous Access in the Simulation Setting for Thai Emergency Medical Service Providers

被引:8
作者
Ienghong, Kamonwon [1 ]
Cheung, Lap Woon [2 ,3 ]
Wongwan, Pornpawit [1 ]
Apiratwarakul, Korakot [1 ,4 ]
机构
[1] Khon Kaen Univ, Fac Med, Dept Emergency Med, Khon Kaen, Thailand
[2] Princess Margaret Hosp, Accid & Emergency Dept, Kowloon, Hong Kong, Peoples R China
[3] Univ Hong Kong, Li Ka Shing Fac Med, Dept Emergency Med, Pokfulam, Hong Kong, Peoples R China
[4] Khon Kaen Univ, Fac Med, Dept Emergency Med, 123 Mittraphap Rd, Khon Kaen 40002, Thailand
关键词
smart glasses; ultrasonography; emergency medical services; VENOUS ACCESS; DISPLAY;
D O I
10.2147/JMDH.S424487
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose: The ultrasound-guided peripheral venous access (USGPIV) was reported as difficult for novices to perform. Smart glasses equipped with teleconference systems can display real-time ultrasound images to sonographers and consultants which can increase the success rate of this procedure. The purpose of this study was to assess the effectiveness of employing smart glasses for USGPIV. Patients and Methods: A randomized, simulation study was conducted in emergency medical service (EMS) providers at Srinagarind Hospital, Thailand, from January to April 2023. We randomized participants into two groups which included participants who wore smart glasses during procedures requiring USGPIV (the smart glasses group) and participants who performed USGPIV with no smart glasses (the non-smart glasses group). After participating in USGPIV cannulation training, the simulations were carried out. The primary outcome was the first-attempt success rate, with secondary outcomes including the procedure time and subjective difficulty. Results: Fifty participants were recruited for the study. The smart glasses group was superior to the non-smart glasses group both in terms of first-attempt success rate with no statistically significant (64% vs 60%; P = 0.460) and also demonstrated a shorter procedure time than the non-smart glasses group (25.5 sec vs 42.3 sec; P = 0.003). The participants reported the subjective difficulty score was higher in the smart glasses group (the visual analog scale, VAS = 8). Conclusion: In simulation scenarios, the smart glasses-assisted USGPIV could shorten the procedure time. However, our study did not find significant differences in the first pass success rate of USGPIV between the two groups.
引用
收藏
页码:2201 / 2206
页数:6
相关论文
共 25 条
[1]   Smart Glasses: A New Tool for Assessing the Number of Patients in Mass-Casualty Incidents [J].
Apiratwarakul, Korakot ;
Cheung, Lap Woon ;
Tiamkao, Somsak ;
Phungoen, Pariwat ;
Tientanopajai, Kitt ;
Taweepworadej, Wiroj ;
Kanarkard, Wanida ;
Ienghong, Kamonwon .
PREHOSPITAL AND DISASTER MEDICINE, 2022, 37 (04) :480-484
[2]   Ultrasound-guided versus traditional method for peripheral venous access: an umbrella review [J].
Berlanga-Macias, Carlos ;
Diez-Fernandez, Ana ;
Martinez-Hortelano, Jose Alberto ;
Sequi-Dominguez, Irene ;
Saz-Lara, Alicia ;
Pozuelo-Carrascosa, Diana ;
Martinez-Vizcaino, Vicente .
BMC NURSING, 2022, 21 (01)
[3]   Can Non-Physician Providers Use Ultrasound to Aid in Establishing Peripheral IV Access in Patients Who are Difficult to Cannulate? A Scoping Review [J].
Burton, Samuel O. ;
Donovan, Jake K. ;
Jones, Samuel L. ;
Meadley, Benjamin N. .
PREHOSPITAL AND DISASTER MEDICINE, 2022, 37 (04) :535-546
[4]   ULTRASOUND PHANTOMS MADE OF GELATIN COVERED WITH HYDROCOLLOID SKIN DRESSING [J].
Chao, Shao-Lun ;
Chen, Kuo-Chih ;
Lin, Li-Wei ;
Wang, Tzong-Luen ;
Chong, Chee-Fah .
JOURNAL OF EMERGENCY MEDICINE, 2013, 45 (02) :240-243
[5]  
Daniel WW., 2013, Biostatistics: A Foundation for Analysis in the Health Sciences, P192
[6]   How I Teach: Ultrasound-guided Peripheral Venous Access [J].
Gorgone, Matthew ;
O'Connor, Timothy P. ;
Maximous, Stephanie I. .
ATS SCHOLAR, 2022, 3 (04) :598-609
[7]  
Ienghong K, 2021, J MED ASS THAI, V104, P35
[8]   Smart Glasses for Radial Arterial Catheterization in Pediatric Patients: A Randomized Clinical Trial [J].
Jang, Young-Eun ;
Cho, Sung-Ae ;
Ji, Sang-Hwan ;
Kim, Eun-Hee ;
Lee, Ji-Hyun ;
Kim, Hee-Soo ;
Kim, Jin-Tae .
ANESTHESIOLOGY, 2021, 135 (04) :612-620
[9]   Education in the placement of ultrasound-guided peripheral venous catheters: a systematic review [J].
Jorgensen, Rasmus ;
Laursen, Christian B. ;
Konge, Lars ;
Pietersen, Pia Iben .
SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2021, 29 (01)
[10]   Ultrasound-Guided Central Venous Catheterization Using an Optical See-Through Head-Mounted Display: A Pilot Study [J].
Kaneko, Naoki ;
Sato, Makoto ;
Takeshima, Taro ;
Sehara, Yoshihide ;
Watanabe, Eiju .