Optimization of hydrogen sensor placement for hydrogen leakage monitoring in the fuel cell truck

被引:17
作者
Liu, Shu [1 ]
He, Ren [1 ]
机构
[1] Jiangsu Univ, Sch Automot & Traff Engn, Zhenjiang 212013, Peoples R China
关键词
Fuel cell truck; Hydrogen leakage detection; Hydrogen sensor; Sensor placement optimization; Scenarios coverage; Scenario detection time; MUNICIPAL WATER NETWORKS; PROGRAMMING APPROACH; FORMULATION; SIMULATION; DETECTORS; MODEL;
D O I
10.1007/s40430-023-04120-1
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Hydrogen safety is one of the most important issues for fuel cell vehicles due to the leakage and wide flammability of hydrogen. It is essential to detect the hydrogen leak to support hydrogen safety. The hydrogen sensors are applied to detect a hydrogen leak. However, the traditional hydrogen sensor placement approaches are rule-of-thumb methods. The performance of hydrogen detection system is greatly affected by the number and placement of sensors. In this paper, the sensor placement is optimized using mixed-integer linear programming formulation. Two optimization objectives are investigated: maximization of scenarios coverage and minimization of scenario detection time. The hydrogen leakage scenarios database is established considering three leakage parameters: release rate, release position and release direction. The hydrogen concentration data are provided from experiment by placing twelve hydrogen sensors on the ceiling of hydrogen storage cabin of fuel cell truck and converted into scenarios coverage and scenario detection time. The results show that the number of hydrogen sensors can be greatly reduced with maximum scenarios coverage and minimum scenario detection time by sensor placement optimization.
引用
收藏
页数:8
相关论文
共 21 条
[1]   Optimal Placement of Gas Detectors: A P-Median Formulation Considering Dynamic Nonuniform Unavailabilities [J].
Benavides-Serrano, A. J. ;
Mannan, M. S. ;
Laird, C. D. .
AICHE JOURNAL, 2016, 62 (08) :2728-2739
[2]   Facility reliability issues in network p-median problems:: Strategic centralization and co-location effects [J].
Berman, Oded ;
Krass, Dmitry ;
Menezes, Mozart B. C. .
OPERATIONS RESEARCH, 2007, 55 (02) :332-350
[3]   Sensor placement in municipal water networks with temporal integer programming models [J].
Berry, Jonathan ;
Hart, William E. ;
Phillips, Cynthia A. ;
Uber, James G. ;
Watson, Jean-Paul .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2006, 132 (04) :218-224
[4]   Designing Contamination Warning Systems for Municipal Water Networks Using Imperfect Sensors [J].
Berry, Jonathan ;
Carr, Robert D. ;
Hart, William E. ;
Leung, Vitus J. ;
Phillips, Cynthia A. ;
Watson, Jean-Paul .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2009, 135 (04) :253-263
[5]   Nature reserve site selection to maximize expected species covered [J].
Camm, JD ;
Norman, SK ;
Polasky, S ;
Solow, AR .
OPERATIONS RESEARCH, 2002, 50 (06) :946-955
[6]  
Daskin M. S., 1982, Decision Sciences, V13, P416, DOI 10.1111/j.1540-5915.1982.tb00159.x
[7]   A MAXIMUM EXPECTED COVERING LOCATION MODEL - FORMULATION, PROPERTIES AND HEURISTIC SOLUTION [J].
DASKIN, MS .
TRANSPORTATION SCIENCE, 1983, 17 (01) :48-70
[8]   Temperature sensor placement optimization for VAV control using CFD-BES co-simulation strategy [J].
Du, Zhimin ;
Xu, Peifan ;
Jin, Xinqiao ;
Liu, Qiaoling .
BUILDING AND ENVIRONMENT, 2015, 85 :104-113
[9]   Sensing advancement towards safety assessment of hydrogen fuel cell vehicles [J].
Foorginezhad, Sahar ;
Mohseni-Dargah, Masoud ;
Falahati, Zahra ;
Abbassi, Rouzbeh ;
Razmjou, Amir ;
Asadnia, Mohsen .
JOURNAL OF POWER SOURCES, 2021, 489 (489)
[10]   CFD analysis of fast filling scenarios for 70 MPa hydrogen type IV tanks [J].
Galassi, M. Cristina ;
Baraldi, Daniele ;
Iborra, Beatriz Acosta ;
Moretto, Pietro .