Low Parts Per Trillion Detection of Iodinated Disinfection Byproducts in Drinking Water and Urine using Vacuum-Assisted Sorbent Extraction and GC-MS/MS

被引:3
|
作者
Justen, Patrick T. [1 ]
Kilpatrick, Madison L. [1 ]
Soto, Joshua L. [1 ]
Richardson, Susan D. [1 ]
机构
[1] Univ South Carolina, Dept Chem & Biochem, Columbia, SC 29208 USA
关键词
disinfection byproducts; DBPs; iodo-THMs; mass spectrometry; VASE; SOLID-PHASE MICROEXTRACTION; ORGANIC-CARBON DOC; IODO-TRIHALOMETHANES; IODIDE; CHLORINATION; EXPOSURE; CHLORAMINATION; OXIDATION; REMOVAL; IMPACT;
D O I
10.1021/acs.est.3c07097
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Disinfection byproducts (DBPs) are ubiquitous environmental contaminants, which are present in virtually all drinking water and linked to detrimental health effects. Iodinated-DBPs are more cytotoxic and genotoxic than chloro- and bromo-DBPs and are formed during disinfection of iodide-containing source water. Liquid-liquid extraction (LLE) paired with gas chromatography (GC)-mass spectrometry (MS) has been the method of choice in the study of low molecular weight iodinated-DBPs; however, this method is laborious and time-consuming and struggles with complex matrices. We developed an environmentally friendly method utilizing headspace solid phase extraction with the application of vacuum to measure six iodinated-trihalomethanes (I-THMs) in drinking water and urine. Vacuum-assisted sorbent extraction (VASE) has the ability to exhaustively and rapidly extract volatile and semivolatile compounds from liquid matrices without the use of solvent. Using VASE with GC-MS/MS provides improved analyte recovery and reduced matrix interference compared to LLE. Additionally, VASE enables extraction of 30 samples simultaneously with minimal sample handling and improved method reproducibility. Using VASE with GC-MS/MS, we achieved quantification limits of 3-4 ng/L. This technique was demonstrated on drinking water from four cities, where five I-THMs were quantified at levels 10-33 times below comparable LLE methods with 10 times lower volumes of sample (10 mL vs 100 mL).
引用
收藏
页码:1321 / 1328
页数:8
相关论文
共 4 条
  • [1] Effective and sensitive determination of eleven disinfection byproducts in drinking water by DLLME and GC-MS
    On, Jiwon
    Pyo, Heesoo
    Myung, Seung-Woon
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 639 : 208 - 216
  • [2] Full Evaporative Vacuum Extraction?A Quantitative and Green Approach for Analysis of Semivolatile Organic Compounds in Drinking Water and Surface Water Using GC-MS
    Hao, Weier
    Cardin, Daniel B.
    ANALYTICAL CHEMISTRY, 2023, 95 (08) : 3959 - 3967
  • [3] Pesticide Determination in Fresh Coconut Water (Cocos nucifera Linn.) by GC-MS Using Microwave-Assisted Liquid-Liquid Extraction
    Nakamura, Thamilin C.
    do Rego, Enoc L.
    de Souza, Jurandir R.
    Diniz, Paulo H. G. D.
    da Silva, Jose D. S.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2023, 34 (11) : 1707 - 1716
  • [4] Ultrasound-Assisted Switchable Solvent in Determination of Quaternary Ammonium Herbicide Paraquat in Biological, Environmental Water, and Apple Juice Samples Using Chemical Reduction Process Coupled to GC-MS Detection
    Lamei, Navid
    Ezoddin, Maryam
    Kakavandi, Nader Rahimi
    Abdi, Khosrou
    Ghazi-khansari, Mahmoud
    CHROMATOGRAPHIA, 2018, 81 (06) : 923 - 930