Design and fabrication of a polydimethylsiloxane device for evaluating the effect of pillar geometry and configuration in the flow separation using deterministic lateral displacement

被引:1
|
作者
Pandit, Pavan [1 ,2 ]
Kong, Lingxue [2 ]
Samuel, G. L. [1 ]
机构
[1] IIT Madras, Dept Mech Engn, Mfg Engn Sect, Chennai 600036, Tamil Nadu, India
[2] Deakin Univ, Inst Frontier Mat, Geelong, Vic 3216, Australia
关键词
CRITICAL PARTICLE-SIZE; ARRAYS; PERFORMANCE; EXOSOMES; CHIP;
D O I
10.1039/d3ra06431j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The advancement of microfluidics and the manufacturing of microdevices has led to a strategic change in the biomedical industry. The flow through narrow channels and the pillars are placed strategically, leading to the phenomenon of particle separation through deterministic lateral displacement (DLD). In such a phenomenon, the shape, size, location and orientation of the obstacles play an important role. For the first time, particle separation is achieved with DLD modules having high row shift angles of 25 degrees, 30 degrees and 35 degrees, reducing the number of pillars. The significance of circular and triangular micropillars executing deterministic lateral displacement, oriented at different angles, has been investigated, and it is found that the triangular pillars oriented at 75 degrees resulted in better separation compared to the other configurations. In this report, the fabrication, location, orientation of the micropillars and the selection of appropriate process parameters are detailed. The structures are fabricated on silicon wafers using the standard photolithography process followed by the deep reactive ion etching process. These dies are further used to fabricate the polydimethylsiloxane-based microfluidic chips. These fabricated devices are characterised by their size, structure and quality using 3D microscopy and scanning electron microscopy. Further, blood plasma separation is carried out using the devices fabricated in this work, and the particles at the inlet and outlets are evaluated using microscopy and a novel image processing technique, replacing the use of a hemocytometer. The path traced by the particles at different flow conditions is numerically evaluated and validated with experiments. The novel device is capable of separating blood cells from plasma with a recovery factor varying from 44% to 100%. PDMS-PDMS bonding experiments using oxygen and argon plasma have been carried out to evaluate the maximum bond strength and flow velocity in the devices. It is observed that the oxygen plasma results in a bond strength of 0.404 N mm-1, thus a high throughput of 135.34 mu L s-1 is achieved using the fabricated device. Design, fabrication and characterisation of deterministic lateral displacement microfluidic devices for particle separation.
引用
收藏
页码:1563 / 1575
页数:13
相关论文
共 6 条
  • [1] Effect of process parameters on separation efficiency in a deterministic lateral displacement device
    Aghajanloo, Behrouz
    Inglis, David W.
    Ejeian, Fatemeh
    Tehrani, Alireza Fadaei
    Esfahani, Mohammad Hossein Nasr
    Saghafian, Mohsen
    Canavese, Giancarlo
    Marasso, Simone L.
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1678
  • [2] New design for the separation of microorganisms using microfluidic deterministic lateral displacement
    Al-Fandi, Mohamed
    Al-Rousan, Mohammad
    Jaradat, Mohammad A. K.
    Al-Ebbini, Lina
    ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2011, 27 (02) : 237 - 244
  • [3] Separation of viable and nonviable mammalian cells using a deterministic lateral displacement microfluidic device
    Tottori, Naotomo
    Nisisako, Takasi
    Park, Jongho
    Yanagida, Yasuko
    Hatsuzawa, Takeshi
    BIOMICROFLUIDICS, 2016, 10 (01):
  • [4] Increasing flow rates in polydimethylsiloxane-based deterministic lateral displacement devices for sub-micrometer particle separation
    Julius Marhenke
    Tobias Dirnecker
    Nicolas Vogel
    Mathias Rommel
    Microfluidics and Nanofluidics, 2023, 27
  • [5] Increasing flow rates in polydimethylsiloxane-based deterministic lateral displacement devices for sub-micrometer particle separation
    Marhenke, Julius
    Dirnecker, Tobias
    Vogel, Nicolas
    Rommel, Mathias
    MICROFLUIDICS AND NANOFLUIDICS, 2023, 27 (01)
  • [6] Separation of Microvesicles from Serological Samples Using Deterministic Lateral Displacement Effect
    Laki A.J.
    Botzheim L.
    Iván K.
    Tamási V.
    Civera P.
    BioNanoScience, 2015, 5 (1) : 48 - 54