Investigation on fire resistance of steel-reinforced concrete-filled steel tubular columns subjected to non-uniform fire

被引:26
作者
Mao, Wen-Jing [1 ]
Zhou, Kan [2 ,3 ]
Wang, Wen-Da [1 ]
机构
[1] Lanzhou Univ Technol, Sch Civil Engn, Lanzhou 730050, Peoples R China
[2] Leeds Beckett Univ, Sch Built Environm Engn & Comp, City Campus, Leeds LS1 3HE, England
[3] Lanzhou Univ Technol, Sch Civil Engn, Lanzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Steel -reinforced concrete -filled steel tubular; (SRCFST) columns; Non -uniform fire; Thermo -mechanical behavior; Finite element (FE) model; Simplified design method; NUMERICAL-ANALYSIS; COMPOSITE COLUMNS; STUB COLUMNS; TUBE COLUMNS; STRENGTH; BEHAVIOR; PERFORMANCE; DESIGN; MODEL;
D O I
10.1016/j.engstruct.2023.115653
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The fire performance of steel-reinforced concrete-filled steel tubular (SRCFST) columns under non-uniform fire exposure is analytically and experimentally examined. Four SRCFST columns are methodically tested under 3-, 2opposite-, 2-adjacent-, and 1-face heating to achieve the failure modes, temperature evolution in time, axial and lateral deformations, and fire resistance. Finite element (FE) analysis models were used to verify and assess the test results. The obtained results reveal that profiled steel benefits the integrity and fire resistance of SRCFST columns. The temperature distribution of the cross-section is substantially affected by uneven temperature distribution, resulting in shifting the stiffness center toward the unexposed side at the elevated temperature. The parametric studies are also conducted over various influential factors to analyze their effects on the fire resistance of SRCFST columns subjected to non-uniform fire. A modified calculation methodology based on the extended Rankine approach is developed to predict the fire resistance of SRCFST columns under various fire conditions, covering uniform fire, 3-, 2-opposite-, 2- adjacent-, and 1-face heating. Based on the quantitative comparisons between the experimentally observed data and the numerically predicted results, the simplified method generally yields accurate predictions on the ultimate load capacity of SRCFST columns under nonuniform fire.
引用
收藏
页数:16
相关论文
共 56 条
[1]  
[Anonymous], 2005, 1994 1 2 EN
[2]  
[Anonymous], 2002, 1991 1 2 EN
[3]  
[Anonymous], 1999, 834 1 1999 ISO
[4]   Study on axial compression bearing capacity of novel concrete-filled square steel tube columns [J].
Chen, Zongping ;
Ning, Fan ;
Song, Chunmei ;
Liang, Yuhan .
JOURNAL OF BUILDING ENGINEERING, 2022, 51
[5]  
Chu TB, 2016, P ROMANIAN ACAD A, V17, P152
[6]   Structural Fire Performance of Concrete-Filled Built-Up Cold-Formed Steel Columns [J].
Craveiro, Helder D. ;
Rahnavard, Rohola ;
Henriques, Jose ;
Simoes, Rui A. .
MATERIALS, 2022, 15 (06)
[7]   Behavior of steel-reinforced concrete-filled square steel tubular stub columns under axial loading [J].
Ding, Fa-xing ;
Zhang, Tao ;
Liu, Xue-mei ;
Lu, Zhao-Hui ;
Guo, Qiang ;
Jiang, Guo-shuai .
THIN-WALLED STRUCTURES, 2017, 119 :737-748
[8]  
Dotreppe JC, 1999, ACI STRUCT J, V96, P9
[9]   Experimental investigation on the fire behaviour of rectangular and elliptical slender concrete-filled tubular columns [J].
Espinos, A. ;
Romero, M. L. ;
Serra, E. ;
Hospitaler, A. .
THIN-WALLED STRUCTURES, 2015, 93 :137-148
[10]   Circular and square slender concrete-filled tubular columns under large eccentricities and fire [J].
Espinos, A. ;
Romero, M. L. ;
Serra, E. ;
Hospitaler, A. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 110 :90-100