Risk-Based Maintenance Strategies on Fishing Vessel Refrigeration Systems Using Fuzzy-FMEA

被引:8
作者
Siahaan, Juniawan Preston [1 ]
Yaqin, Rizqi Ilmal [1 ]
Priharanto, Yuniar Endri [1 ]
Abrori, M. Zaki Latif [1 ]
Siswantoro, Nurhadi [2 ]
机构
[1] Politeknik Kelautan dan Perikanan Dumai, Dept Ship Machinery, Dumai, Riau, Indonesia
[2] Inst Teknol Sepuluh Nopember, Dept Marine Engn, Surabaya, East Java, Indonesia
关键词
COP; FMEA; Fuzzy-FMEA; Refrigeration; FAILURE MODE; CRITICALITY ANALYSIS; PERFORMANCE; OPTIMIZATION; EFFICIENCY; PRIORITIZATION;
D O I
10.1007/s11668-024-01878-x
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Applying the fuzzy logic method to FMEA and its correlation with performance investigations is rarely applied in analyzing refrigeration system risk. The aim of this study is investigate the refrigeration system performance and analyze the risk of failure mode in the performance of the refrigeration system using the fuzzy-FMEA method. In calculating performance, the COP parameter is needed. Prioritization of failure modes uses conventional FMEA (C-FMEA) and fuzzy-based FMEA (Fuzzy-FMEA), which produces conventional RPN (C-RPN) and fuzzy-RPN (F-RPN). Pareto diagrams are used to classify RPN categories which are the main causes. The result of the study is that the calculation of the refrigeration system performance shows a decreasing trend with increasing operating time. In the risk analysis, it was found that the F21 (evaporator) failure has the same rating, and the highest is C-RPN (252) and F-RPN (750). Five categories need to be mitigated. The application of fuzzy-FMEA determines the critical failure priority of the evaporator. The results of this study provide new insights into developing engine performance investigations by determining critical failure modes to get mitigation quickly by minimizing expert opinion expertise.
引用
收藏
页码:855 / 876
页数:22
相关论文
共 56 条
  • [1] The risk analysis by failure mode and effect analysis (FMEA) and fuzzy-FMEA of supercritical water gasification system used in the sewage sludge treatment
    Adar, Elanur
    Ince, Mahir
    Karatop, Buket
    Bilgili, Mehmet Sinan
    [J]. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2017, 5 (01): : 1261 - 1268
  • [2] Effect of evaporator temperature on vapor compression refrigeration system
    Al-Rashed, Abdullah A. A. A.
    [J]. ALEXANDRIA ENGINEERING JOURNAL, 2011, 50 (04) : 283 - 290
  • [3] The role of maintenance in improving companies' productivity and profitability
    Alsyouf, Imad
    [J]. INTERNATIONAL JOURNAL OF PRODUCTION ECONOMICS, 2007, 105 (01) : 70 - 78
  • [4] Failure Modes and Effects Analysis (FMEA) for wind turbines
    Arabian-Hoseynabadi, H.
    Oraee, H.
    Tavner, P. J.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2010, 32 (07) : 817 - 824
  • [5] Investigation on the performance improvement of household refrigeration system using R-134a refrigerant blended with ceria nano additives
    Arumuganainar, K.
    Edwin, M.
    Raj, J. Bensam
    [J]. APPLIED NANOSCIENCE, 2022, 12 (05) : 1753 - 1761
  • [6] Optimization of a multistage vapor-compression refrigeration system for various refrigerants
    Baakeem, Saleh S.
    Orfi, Jamel
    Alabdulkarem, Abdullah
    [J]. APPLIED THERMAL ENGINEERING, 2018, 136 : 84 - 96
  • [7] Backlund F., 2002, Journal of Quality in Maintenance Engineering, V8, P77, DOI DOI 10.1108/13552510210420603
  • [8] Baig M. H. A., 2013, INT J ADV INFORM SCI, V13, P2
  • [9] Balaraju J., 2019, J. Sustain. Min, V18, P257, DOI [10.1016/j.jsm.2019.08.002, DOI 10.1016/J.JSM.2019.08.002]
  • [10] Real-time monitoring energy efficiency and performance degradation of condensing boilers
    Baldi, Simone
    Quang, Thuan Le
    Holub, Ondrej
    Endel, Petr
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 136 : 329 - 339