Determining Accurate Dye Combinations for Sentinel Lymph Node Detection: A Systematic Review

被引:0
作者
Swerdlow, Mark [1 ,2 ]
Vangsness, Kella L. [1 ]
Kress, Gavin T. [1 ,2 ]
Georgescu, Anda [1 ]
Wong, Alex K. [1 ]
Carre, Antoine Lyonel [1 ,3 ]
机构
[1] City Hope Natl Med Ctr, Div Plast Surg, Duarte, CA USA
[2] Keck Sch Med USC, Dept Surg, 1520 San Pablo St,Suite 4300, Los Angeles, CA 90033 USA
[3] City Hope Natl Med Ctr, Dept Surg, 1500 East Duarte Rd, Duarte, CA 91010 USA
关键词
METHYLENE-BLUE DYE; INDOCYANINE GREEN; BREAST-CANCER; PATENT BLUE; BIOPSY; FLUORESCENCE; LYMPHOSCINTIGRAPHY; RADIOISOTOPE; TRACER; LYMPHADENECTOMY;
D O I
10.1097/GOX.0000000000005598
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Lymphatic dyes are commonly used to map the drainage path from tumor to lymphatics, which are biopsied to determine if spread has occurred. A blue dye in combination with technetium-99 is considered the gold standard for mapping, although many other dyes and dye combinations are used. Not all of these substances have the same detection efficacy. Methods: A systematic review of PubMed, SCOPUS, Web of Science, and Medline was performed. The predefined search terms were (indocyanine green OR isosulfan blue OR lymphazurin OR patent blue OR methylene blue OR fluorescein OR technetium-99) AND combination AND dye AND (sentinel lymph node biopsy OR lymphedema OR lymphatics OR lymph OR microsurgery OR cancer OR tumor OR melanoma OR carcinoma OR sarcoma). Results: The initial search returned 4267 articles. From these studies, 37 were selected as candidates that met inclusion criteria. After a full-text review, 34 studies were selected for inclusion. Eighty-nine methods of sentinel lymph node (SLN) detection were trialed using 22 unique dyes, dye combinations, or other tracers. In total, 12,157 SLNs of 12,801 SLNs were identified. Dye accuracy ranged from 100% to 69.8% detection. Five dye combinations had 100% accuracy. Dye combinations were more accurate than single dyes. Conclusions: Combining lymphatic dyes improves SLN detection results. Replacing technetium-99 with ICG may allow for increased access to SLN procedures with comparable results. The ideal SLN tracer is a low-cost molecule with a high affinity for lymphatic vessels due to size and chemical composition, visualization without specialized equipment, and no adverse effects.
引用
收藏
页数:8
相关论文
共 76 条
[31]   Comparison of intradermal and subcutaneous injections in lymphatic mapping [J].
Kersey, TW ;
Van Eyk, J ;
Lannin, DR ;
Chua, AN ;
Tafra, L .
JOURNAL OF SURGICAL RESEARCH, 2001, 96 (02) :255-259
[32]   Methylene Blue Dye-Induced Skin Necrosis in Immediate Breast Reconstruction: Evaluation and Management [J].
Lee, Ji Hwan ;
Chang, Choong Hyun ;
Park, Chan Heun ;
Kim, June-Kyu .
ARCHIVES OF PLASTIC SURGERY-APS, 2014, 41 (03) :258-263
[33]   Adverse reactions to isosulfan blue during selective sentinel lymph node dissection in melanoma [J].
Leong, SPL ;
Donegan, E ;
Heffermon, W ;
Dean, S ;
Katz, JA .
ANNALS OF SURGICAL ONCOLOGY, 2000, 7 (05) :361-366
[34]   Indocyanine green fluorescence method for sentinel lymph node biopsy in breast cancer [J].
Lin, Joseph ;
Lin, Li-Sheng ;
Chen, Dar-Ren ;
Lin, Kuo-Juei ;
Wang, Yu-Fen ;
Chang, Yu-Jun .
ASIAN JOURNAL OF SURGERY, 2020, 43 (12) :1149-1153
[35]  
Mathelin C, 2009, ANTICANCER RES, V29, P4119
[36]   Particle-Size and Radiochemical Purity Evaluations of Filtered Tc-99m-Sulfur Colloid Prepared with Different Heating Times [J].
Michenfelder, Maggie M. ;
Bartlett, Lucas J. ;
Mahoney, Douglas W. ;
Herold, Thomas J. ;
Hung, Joseph C. .
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2014, 42 (04) :283-288
[37]   Network meta-analysis of novel and conventional sentinel lymph node biopsy techniques in breast cancer [J].
Mok, C. W. ;
Tan, S-M ;
Zheng, Q. ;
Shi, L. .
BJS OPEN, 2019, 3 (04) :445-452
[38]   INTRAOPERATIVE LYMPHATIC MAPPING AND SELECTIVE CERVICAL LYMPHADENECTOMY FOR EARLY-STAGE MELANOMAS OF THE HEAD AND NECK [J].
MORTON, DL ;
WEN, DR ;
FOSHAG, LJ ;
ESSNER, R ;
COCHRAN, A .
JOURNAL OF CLINICAL ONCOLOGY, 1993, 11 (09) :1751-1756
[39]   Sentinel node biopsy for early-stage melanoma - Accuracy and morbidity in MSLT-I, an international multicenter trial [J].
Morton, DL ;
Cochran, AJ ;
Thompson, JF ;
Elashoff, R ;
Essner, R ;
Glass, EC ;
Mozzillo, N ;
Nieweg, OE ;
Roses, DF ;
Hoekstra, HJ ;
Karakousis, CP ;
Reintgen, DS ;
Coventry, BJ ;
Wang, HJ .
ANNALS OF SURGERY, 2005, 242 (03) :302-313
[40]  
MORTON DL, 1992, ARCH SURG-CHICAGO, V127, P392