Determining Accurate Dye Combinations for Sentinel Lymph Node Detection: A Systematic Review

被引:0
作者
Swerdlow, Mark [1 ,2 ]
Vangsness, Kella L. [1 ]
Kress, Gavin T. [1 ,2 ]
Georgescu, Anda [1 ]
Wong, Alex K. [1 ]
Carre, Antoine Lyonel [1 ,3 ]
机构
[1] City Hope Natl Med Ctr, Div Plast Surg, Duarte, CA USA
[2] Keck Sch Med USC, Dept Surg, 1520 San Pablo St,Suite 4300, Los Angeles, CA 90033 USA
[3] City Hope Natl Med Ctr, Dept Surg, 1500 East Duarte Rd, Duarte, CA 91010 USA
关键词
METHYLENE-BLUE DYE; INDOCYANINE GREEN; BREAST-CANCER; PATENT BLUE; BIOPSY; FLUORESCENCE; LYMPHOSCINTIGRAPHY; RADIOISOTOPE; TRACER; LYMPHADENECTOMY;
D O I
10.1097/GOX.0000000000005598
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Lymphatic dyes are commonly used to map the drainage path from tumor to lymphatics, which are biopsied to determine if spread has occurred. A blue dye in combination with technetium-99 is considered the gold standard for mapping, although many other dyes and dye combinations are used. Not all of these substances have the same detection efficacy. Methods: A systematic review of PubMed, SCOPUS, Web of Science, and Medline was performed. The predefined search terms were (indocyanine green OR isosulfan blue OR lymphazurin OR patent blue OR methylene blue OR fluorescein OR technetium-99) AND combination AND dye AND (sentinel lymph node biopsy OR lymphedema OR lymphatics OR lymph OR microsurgery OR cancer OR tumor OR melanoma OR carcinoma OR sarcoma). Results: The initial search returned 4267 articles. From these studies, 37 were selected as candidates that met inclusion criteria. After a full-text review, 34 studies were selected for inclusion. Eighty-nine methods of sentinel lymph node (SLN) detection were trialed using 22 unique dyes, dye combinations, or other tracers. In total, 12,157 SLNs of 12,801 SLNs were identified. Dye accuracy ranged from 100% to 69.8% detection. Five dye combinations had 100% accuracy. Dye combinations were more accurate than single dyes. Conclusions: Combining lymphatic dyes improves SLN detection results. Replacing technetium-99 with ICG may allow for increased access to SLN procedures with comparable results. The ideal SLN tracer is a low-cost molecule with a high affinity for lymphatic vessels due to size and chemical composition, visualization without specialized equipment, and no adverse effects.
引用
收藏
页数:8
相关论文
共 76 条
[1]   Diagnostic Performance of Indocyanine Green Plus Methylene Blue Versus Radioisotope Plus Methylene Blue Dye Method for Sentinel Lymph Node Biopsy in Node-Negative Early Breast Cancer [J].
Agrawal, Sanjit Kumar ;
Hashlamoun, Izideen ;
Karki, Banira ;
Sharma, Abhishek ;
Arun, Indu ;
Ahmed, Rosina .
JCO GLOBAL ONCOLOGY, 2020, 6 :1225-1231
[2]   Novel techniques for sentinel lymph node biopsy in breast cancer: a systematic review [J].
Ahmed, Muneer ;
Purushotham, Arnie D. ;
Douek, Michael .
LANCET ONCOLOGY, 2014, 15 (08) :E351-E362
[3]  
Berrocal Julian, 2017, Surg Res Pract, V2017, P5924802, DOI [10.1155/2017/5924802, 10.1155/2017/5924802]
[4]   FLUORESCENCE MICROLYMPHOGRAPHY [J].
BOLLINGER, A ;
JAGER, K ;
SGIER, F ;
SEGLIAS, J .
CIRCULATION, 1981, 64 (06) :1195-1200
[5]   Clinical applications of indocyanine green (ICG) enhanced fluorescence in laparoscopic surgery [J].
Boni, Luigi ;
David, Giulia ;
Mangano, Alberto ;
Dionigi, Gianlorenzo ;
Rausei, Stefano ;
Spampatti, Sebastiano ;
Cassinotti, Elisa ;
Fingerhut, Abe .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (07) :2046-2055
[6]   A Hybrid Radioactive and Fluorescent Tracer for Sentinel Node Biopsy in Penile Carcinoma as a Potential Replacement for Blue Dye [J].
Brouwer, Oscar R. ;
van den Berg, Nynke S. ;
Matheron, Hanna M. ;
van der Poel, Henk G. ;
van Rhijn, Bas W. ;
Bex, Axel ;
van Tinteren, Harm ;
Olmos, Renato A. Valdes ;
van Leeuwen, Fijs W. B. ;
Horenblas, Simon .
EUROPEAN UROLOGY, 2014, 65 (03) :600-609
[7]   Comparing the Hybrid Fluorescent-Radioactive Tracer Indocyanine Green-99mTc-Nanocolloid with 99mTc-Nanocolloid for Sentinel Node Identification: A Validation Study Using Lymphoscintigraphy and SPECT/CT [J].
Brouwer, Oscar R. ;
Buckle, Tessa ;
Vermeeren, Lenka ;
Klop, W. Martin C. ;
Balm, Alfons J. M. ;
van der Poel, Henk G. ;
van Rhijn, Bas W. ;
Horenblas, Simon ;
Nieweg, Omgo E. ;
van Leeuwen, Fijs W. B. ;
Olmos, Renato A. Valdes .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (07) :1034-1040
[8]   Quality of Care for Cervical and Endometrial Cancer Patients: The Impact of Different Techniques of Sentinel Lymph Node Mapping on Patient Satisfaction [J].
Buda, Alessandro ;
Elisei, Federica ;
Palazzi, Sharon ;
De Ponti, Elena ;
Arosio, Maurizio ;
Vecchione, Francesca ;
Dell'Anna, Tiziana ;
Cuzzocrea, Marco ;
Bussi, Beatrice ;
Giuliani, Daniela ;
Di Martino, Giampaolo ;
Crivellaro, Cinzia .
ANNALS OF SURGICAL ONCOLOGY, 2016, 23 (09) :2975-2981
[9]   Technetium-99m-indocyanine green versus technetium-99m-methylene blue for sentinel lymph node biopsy in early-stage endometrial cancer [J].
Cabrera, Silvia ;
Bebia, Vicente ;
Franco-Camps, Silvia ;
Forcada, Cristina ;
Villasboas-Rosciolesi, Diego ;
Navales, Ignacio ;
Perez-Benavente, Assumpcio ;
Gil-Moreno, Antonio .
INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2020, 30 (03) :311-317
[10]  
Chen Junxue, 2002, Zhonghua Wai Ke Za Zhi, V40, P164