Development of Quantitative Real-Time PCR and Loop-Mediated Isothermal Amplification Assays for the Surveillance and Diagnosis of Herpes B Virus Infection

被引:2
作者
Amano, Murasaki [1 ,2 ,3 ]
Sapkanarak, Krittiga [4 ,5 ]
Thbthimthong, Wipaporn [4 ]
Meesawat, Suthirote [4 ,5 ]
Kemthong, Taratorn [4 ,5 ]
Suttisan, Nutchanat [4 ]
Abe, Haruka [1 ,6 ]
Malaivijitnond, Suchinda [4 ,5 ]
Yasuda, Jiro [1 ,2 ,3 ]
机构
[1] Nagasaki Univ, Natl Res Ctr Control & Prevent Infect Dis CCPID, Dept Emerging Infect Dis, Nagasaki 8528523, Japan
[2] Nagasaki Univ, Grad Sch Biomed Sci, Program Nurturing Global Leaders Trop & Emerging C, Nagasaki 8528523, Japan
[3] Nagasaki Univ, Inst Trop Med, Dept Emerging Infect Dis, Nagasaki 8528523, Japan
[4] Chulalongkorn Univ, Natl Primate Res Ctr Thailand, Sara Buri 18110, Thailand
[5] Chulalongkorn Univ, Fac Sci, Dept Biol, Bangkok 10330, Thailand
[6] Nagasaki Univ, Inst Trop Med NEKKEN, Vietnam Res Stn, Nagasaki 8528523, Japan
来源
VIRUSES-BASEL | 2023年 / 15卷 / 10期
关键词
herpes B virus; zoonosis; LAMP; surveillance; cynomolgus macaque; SENSITIVE DETECTION; EBOLA-VIRUS; MACAQUES; ANTIBODY; EXPOSURE; PRIMATES; SIMIAE;
D O I
10.3390/v15102086
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Herpes B virus (BV) is a zoonotic virus which can be transmitted from macaques to humans, which is often associated with high mortality rates. Because macaques often exhibit asymptomatic infections, individuals who come into contact with these animals face unexpected risks of BV infections. A serological test is widely performed to investigate BV infections. However, the assay's sensitivity and specificity appeared to be inadequate, and it does not necessarily indicate ongoing viral shedding. Here, we developed LAMP and qPCR assays aiming to detect BVs with a high sensitivity and specificity in various macaque species and validated them using oral swab samples collected from 97 wild cynomolgus macaques living in Thailand. Our LAMP and qPCR assays detected more than 50 and 10 copies of the target sequences per reaction, respectively. The LAMP assay could detect BV within 25 min, indicating its advantages for the rapid detection of BV. Collectively, our findings indicated that both assays developed in this study exhibit advantages and usefulness for BV surveillance and the diagnosis of BV infections in macaques. Furthermore, for the first time, we determined the partial genome sequences of BVs detected in cynomolgus macaques in Thailand. Phylogenetic analysis revealed the species-specific evolution of BV within macaques.
引用
收藏
页数:13
相关论文
共 50 条
[21]   Field Evaluation of a Real-Time Fluorescence Loop-Mediated Isothermal Amplification Assay, RealAmp, for the Diagnosis of Malaria in Thailand and India [J].
Patel, Jaymin C. ;
Lucchi, Naomi W. ;
Srivastava, Priyanka ;
Lin, Jessica T. ;
Sug-aram, Rungniran ;
Aruncharus, Supannee ;
Bharti, Praveen K. ;
Shukla, Man M. ;
Congpuong, Kanungnit ;
Satimai, Wichai ;
Singh, Neeru ;
Udhayakumar, Venkatachalam ;
Meshnick, Steven R. .
JOURNAL OF INFECTIOUS DISEASES, 2014, 210 (08) :1180-1187
[22]   Development of a Real-Time Loop-Mediated Isothermal Amplification Assay for the Rapid Detection of Olea Europaea Geminivirus [J].
Bertacca, Sofia ;
Caruso, Andrea Giovanni ;
Trippa, Daniela ;
Marchese, Annalisa ;
Giovino, Antonio ;
Matic, Slavica ;
Noris, Emanuela ;
San Ambrosio, Maria Isabel Font ;
Alfaro, Ana ;
Panno, Stefano ;
Davino, Salvatore .
PLANTS-BASEL, 2022, 11 (05)
[23]   Multiple Endonuclease Restriction Real-Time Loop-Mediated Isothermal Amplification A Novel Analytically Rapid, Sensitive, Multiplex Loop-Mediated Isothermal Amplification Detection Technique [J].
Wang, Yi ;
Wang, Yan ;
Lan, Ruiting ;
Xu, Huaqing ;
Ma, Aijing ;
Li, Dongxun ;
Dai, Hang ;
Yuan, Xuejiao ;
Xu, Jianguo ;
Ye, Changyun .
JOURNAL OF MOLECULAR DIAGNOSTICS, 2015, 17 (04) :392-401
[24]   Development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis [J].
Mohamed E. Ahmed ;
Mawahib H. Eldigail ;
Fatima M. Elamin ;
Ibtisam A. Ali ;
Martin P. Grobusch ;
Imadeldin E. Aradaib .
BMC Veterinary Research, 12
[25]   Developing a real-time quantitative loop-mediated isothermal amplification assay as a rapid and accurate method for detection of Brucellosis [J].
Soleimani, M. ;
Shams, S. ;
Majidzadeh-A, K. .
JOURNAL OF APPLIED MICROBIOLOGY, 2013, 115 (03) :828-834
[26]   Quantitative analysis of DNA methylation using sequence-specific, real-time loop-mediated isothermal amplification [J].
Fu, Yao ;
Zhang, Li ;
Xing, Yu ;
Deng, Shixiong .
ANALYTICA CHIMICA ACTA, 2022, 1235
[27]   Development of loop-mediated isothermal amplification assays for rapid and easy detection of Coxiella Burnetii [J].
Chen, Hua-Wei ;
Ching, Wei-Mei .
JOURNAL OF MICROBIOLOGICAL METHODS, 2014, 107 :176-181
[28]   Loop-mediated isothermal amplification assay for the diagnosis of retinitis caused by herpes simplex virus-1 [J].
Reddy, A. K. ;
Balne, P. K. ;
Reddy, R. K. ;
Mathai, A. ;
Kaur, I. .
CLINICAL MICROBIOLOGY AND INFECTION, 2011, 17 (02) :210-213
[29]   Real-time loop-mediated isothermal amplification assay for rapid detection of Fusarium circinatum [J].
Stehlikova, Dagmar ;
Luchi, Nicola ;
Aglietti, Chiara ;
Lucia Pepori, Alessia ;
Javier Diez, Julio ;
Santini, Alberto .
BIOTECHNIQUES, 2020, 69 (01) :11-17
[30]   Rapid detection of Streptococcus pneumoniae by real-time fluorescence loop-mediated isothermal amplification [J].
Xia, Yong ;
Guo, Xu-Guang ;
Zhou, Shan .
JOURNAL OF THORACIC DISEASE, 2014, 6 (09) :1193-1199