Carboxymethylated maltodextrin as a chiral selector for the separation of some basic drug enantiomers using capillary electrophoresis

被引:7
|
作者
Alawadi, Mustafa [1 ]
Fakhari, Ali Reza [1 ]
Bayatloo, Mohammad Reza [1 ]
Nojavan, Saeed [1 ]
机构
[1] Shahid Beheshti Univ, Dept Analyt Chem & Pollutants, Tehran, Iran
关键词
Carboxymethylated maltodextrin; Basic drugs; Capillary electrophoresis; Enantiomer separation; PHARMACEUTICAL FORMULATIONS; AMLODIPINE ENANTIOMERS; IONIC LIQUID; ENANTIOSEPARATION; QUANTIFICATION; CYCLODEXTRIN;
D O I
10.1016/j.chroma.2023.464335
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, carboxymethylated maltodextrin (Cm-MD) was successfully synthesized as an efficient anionic chiral selector and applied for the enantiomer separation of some basic drugs including tramadol, venlafaxine, verapamil, hydroxyzine, citalopram, fluoxetine, and amlodipine by capillary electrophoresis (CE). The synthesized chiral selector was characterized by the nuclear magnetic resonance and Fourier transform infrared spectrophotometry. Under the optimized Cm-MD modified CE conditions (background electrolyte: phosphate buffer (pH 5.0, 50 mM) containing 5% (w/v) Cm-MD; applied voltage: 20 kV; and capillary column temperature: 25 C), successful enantiomer separation of all studied chiral drugs were observed. By comparison of Cm-MD and MD for enantiomer separation of the model drugs, it was revealed that Cm-MD exhibits a higher resolution in comparison to the MD modified CE. This enhanced resolution could be attributed to the electrostatic interactions between the cationic drugs and anionic Cm-MD and opposite direction mobility of the host-guest complex relative to the chiral analyte. The optimized Cm-MD modified CE method was successfully used for the assay of the enantiomers of citalopram and venlafaxine in commercial tablets. The proposed method showed the linear range of 5.0-150.0 mg/L and 10.0-150.0 mg/L for both enantiomers of citalopram and venlafaxine, respectively. The limits of quantification were 5.0 and 10.0 mg/L for the enantiomers of citalopram and venlafaxine, respectively. The limit of detection for all enantiomers was found to be < 3.0 mg/L. Intra-and inter-day RSDs (n = 4) were less than 9.7%. The relative errors were less than 9.4% for all enantiomers. The obtained results in this research show that Cm-MD as a new, efficient and inexpensive chiral selector can be used for enantiomer separation of basic drugs using the CE technique.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Chiral Separation of the Enantiomers of Omeprazole and Pantoprazole by Capillary Electrophoresis
    Hancu, Gabriel
    Papp, Lajos Attila
    Rusu, Aura
    CHROMATOGRAPHIA, 2015, 78 (3-4) : 279 - 284
  • [22] Boric acid modified β-CD polymer as chiral selector for chiral drug separation using gravity mediated capillary electrophoresis
    Nan, Yaqin
    Yuan, Xiaoqian
    Xu, Xinyu
    Xu, Yanmei
    Jin, Xinghua
    Li, Youxin
    MICROCHEMICAL JOURNAL, 2025, 210
  • [23] Enantiomer separation by capillary electrophoresis using highly sulfated cyclodextrins as a chiral selector
    Kuwahara, Y
    Izumoto, S
    Nishi, H
    BUNSEKI KAGAKU, 2001, 50 (01) : 69 - 77
  • [24] Chiral Separation of the Enantiomers of Omeprazole and Pantoprazole by Capillary Electrophoresis
    Gabriel Hancu
    Lajos Attila Papp
    Aura Rusu
    Chromatographia, 2015, 78 : 279 - 284
  • [25] Chiral separation of 12 pairs of enantiomers by capillary electrophoresis using heptakis-(2,3-diacetyl-6-sulfato)-β-cyclodextrin as the chiral selector and the elucidation of the chiral recognition mechanism by computational methods
    Yao, Yaqi
    Song, Peilu
    Wen, Xiaoli
    Deng, Miaoduo
    Wang, Jian
    Guo, Xingjie
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (14) : 2999 - 3007
  • [26] Capillary electrophoresis chiral separation of basic pharmaceutical enantiomers with different charges using sulfated β-cyclodextrin
    Wang, F
    Khaledi, MG
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1999, 11 (01) : 11 - 21
  • [27] Chiral Separation of Indapamide Enantiomers by Capillary Electrophoresis
    Tero-Vescan, Amelia
    Hancu, Gabriel
    Oroian, Mihaela
    Carje, Anca
    ADVANCED PHARMACEUTICAL BULLETIN, 2014, 4 (03) : 267 - 272
  • [28] Chiral separation of binaphthol enantiomers in capillary electrophoresis
    Wang, RY
    Lu, XN
    Wu, MJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (01) : 73 - 76
  • [29] Separation of drug enantiomers by capillary electrophoresis alpha-cyclodextrin as chiral solvating agent
    Lin, BC
    Ji, YB
    Chen, YY
    Epperlein, U
    Koppenhoefer, B
    CHROMATOGRAPHIA, 1996, 42 (1-2) : 106 - 110
  • [30] Study on the separation of ofloxacin enantiomers by hydroxyl-propyl-β-cyclodextrin as a chiral selector in capillary electrophoresis: a computational approach
    FakhrEldin O. Suliman
    Abdalla A. Elbashir
    Oliver J. Schmitz
    Journal of Inclusion Phenomena and Macrocyclic Chemistry, 2015, 83 : 119 - 129