Stiffness pulsation of the human brain detected by non-invasive time-harmonic elastography

被引:5
作者
Meyer, Tom [1 ]
Kreft, Bernhard [1 ]
Bergs, Judith [1 ]
Antes, Erik [1 ]
Anders, Matthias S. [1 ]
Wellge, Brunhilde [1 ]
Braun, Juergen [2 ]
Doyley, Marvin [3 ]
Tzschaetzsch, Heiko [1 ]
Sack, Ingolf [1 ]
机构
[1] Charite Univ Med Berlin, Dept Radiol, Berlin, Germany
[2] Charite Univ Med Berlin, Inst Med Informat, Berlin, Germany
[3] Univ Rochester, Hajim Sch Engn & Appl Sci, Rochester, NY USA
关键词
ultrasound time-harmonic elastography; in vivo brain stiffness; brain pulsation; cerebrovascular compliance; intracranial pressure; MAGNETIC-RESONANCE ELASTOGRAPHY; WFUMB GUIDELINES; CLINICAL-USE; TRANSCRANIAL DOPPLER; RECOMMENDATIONS; TISSUE; LIVER;
D O I
10.3389/fbioe.2023.1140734
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction: Cerebral pulsation is a vital aspect of cerebral hemodynamics. Changes in arterial pressure in response to cardiac pulsation cause cerebral pulsation, which is related to cerebrovascular compliance and cerebral blood perfusion. Cerebrovascular compliance and blood perfusion influence the mechanical properties of the brain, causing pulsation-induced changes in cerebral stiffness. However, there is currently no imaging technique available that can directly quantify the pulsation of brain stiffness in real time. Methods: Therefore, we developed non-invasive ultrasound time-harmonic elastography (THE) technique for the real-time detection of brain stiffness pulsation. We used state-of-the-art plane-wave imaging for interleaved acquisitions of shear waves at a frequency of 60 Hz to measure stiffness and color flow imaging to measure cerebral blood flow within the middle cerebral artery. In the second experiment, we used cost-effective lineby-line B-mode imaging to measure the same mechanical parameters without flow imaging to facilitate future translation to the clinic. Results: In 10 healthy volunteers, stiffness increased during the passage of the arterial pulse wave from 4.8% +/- 1.8% in the temporal parenchyma to 11% +/- 5% in the basal cisterns and 13% +/- 9% in the brain stem. Brain stiffness peaked in synchrony with cerebral blood flow at approximately 180 +/- 30 ms after the cardiac R-wave. Line-by-line THE provided the same stiffness values with similar time resolution as high-end plane-wave THE, demonstrating the robustness of brain stiffness pulsation as an imaging marker. Discussion: Overall, this study sets the background and provides reference values for time-resolved THE in the human brain as a cost-efficient and easy-touse mechanical biomarker associated with cerebrovascular compliance.
引用
收藏
页数:9
相关论文
共 47 条
  • [1] Quantifying cardiac-induced brain tissue expansion using DENSE
    Adams, Ayodeji L.
    Kuijf, Hugo J.
    Viergever, Max A.
    Luijten, Peter R.
    Zwanenburg, Jaco J. M.
    [J]. NMR IN BIOMEDICINE, 2019, 32 (02)
  • [2] Acute pressure changes in the brain are correlated with MR elastography stiffness measurements: initial feasibility in an in vivo large animal model
    Arani, Arvin
    Min, Hoon-Ki
    Fattahi, Nikoo
    Wetjen, Nicholas M.
    Trzasko, Joshua D.
    Manduca, Armando
    Jack, Clifford R., Jr.
    Lee, Kendall H.
    Ehman, Richard L.
    Huston, John, III
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 1043 - 1051
  • [3] WFUMB GUIDELINES AND RECOMMENDATIONS ON THE CLINICAL USE OF ULTRASOUND ELASTOGRAPHY: PART 4. THYROID
    Cosgrove, David
    Barr, Richard
    Bojunga, Joerg
    Cantisani, Vito
    Chammas, Maria Cristina
    Dighe, Manjiri
    Vinayak, Sudhir
    Xu, Jun-Mei
    Dietrich, Christoph F.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (01) : 4 - 26
  • [4] TRANSTEMPORAL INVESTIGATION OF BRAIN PARENCHYMA ELASTICITY USING 2-D SHEAR WAVE ELASTOGRAPHY: DEFINITION OF AGE-MATCHED NORMAL VALUES
    Ertl, Michael
    Raasch, Nele
    Hammel, Gertrud
    Harter, Katharina
    Lang, Christopher
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (01) : 78 - 84
  • [5] WFUMB GUIDELINES AND RECOMMENDATIONS FOR CLINICAL USE OF ULTRASOUND ELASTOGRAPHY: PART 3: LIVER
    Ferraioli, Giovanna
    Filice, Carlo
    Castera, Laurent
    Choi, Byung Ihn
    Sporea, Ioan
    Wilson, Stephanie R.
    Cosgrove, David
    Dietrich, Christoph F.
    Amy, Dominique
    Bamber, Jeffrey C.
    Barr, Richard
    Chou, Yi-Hong
    Ding, Hong
    Farrokh, Andre
    Friedrich-Rust, Mireen
    Hall, Timothy J.
    Nakashima, Kazutaka
    Nightingale, Kathryn R.
    Palmeri, Mark L.
    Schafer, Fritz
    Shiina, Tsuyoshi
    Suzuki, Shinichi
    Kudo, Masatoshi
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05) : 1161 - 1179
  • [6] Forouhandehpour R., 2021, Neuroimage Rep, V1, P100014, DOI [10.1016/j.ynirp.2021.100014, DOI 10.1016/J.YNIRP.2021.100014]
  • [7] Tomoelastography of the native kidney: Regional variation and physiological effects on in vivo renal stiffness
    Garcia, Stephan Rodrigo Marticorena
    Grossmann, Markus
    Lang, Sophia Theresa
    Tzschaetzsch, Heiko
    Dittmann, Florian
    Hamm, Bernd
    Braun, Juergen
    Guo, Jing
    Sack, Ingolf
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 2126 - 2134
  • [8] Ge GR, 2022, PHYS MED BIOL, V67, DOI [10.1088/1361-6560/ac9e40, 10.1088/1361-6530/ac9e40]
  • [9] Cerebral tomoelastography based on multifrequency MR elastography in two and three dimensions
    Herthum, Helge
    Hetzer, Stefan
    Kreft, Bernhard
    Tzschaetzsch, Heiko
    Shahryari, Mehrgan
    Meyer, Tom
    Goerner, Steffen
    Neubauer, Hennes
    Guo, Jing
    Braun, Juergen
    Sack, Ingolf
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [10] Real-Time Multifrequency MR Elastography of the Human Brain Reveals Rapid Changes in Viscoelasticity in Response to the Valsalva Maneuver
    Herthum, Helge
    Shahryari, Mehrgan
    Tzschaetzsch, Heiko
    Schrank, Felix
    Warmuth, Carsten
    Goerner, Steffen
    Hetzer, Stefan
    Neubauer, Hennes
    Pfeuffer, Josef
    Braun, Juergen
    Sack, Ingolf
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9