Risk of midline catheter-related thrombosis due to catheter diameter: An observational cohort study

被引:6
作者
Bahl, Amit [1 ,4 ]
Mielke, Nicholas [2 ]
Xing, Yuying [3 ]
机构
[1] William Beaumont Univ Hosp, Corewell Hlth, Dept Emergency Med, Royal Oak, MI USA
[2] Oakland Univ, William Beaumont Sch Med, Rochester, MI USA
[3] Corewell Hlth Res Inst, Royal Oak, MI USA
[4] Beaumont Hosp, Dept Emergency Med, 3601 13 Mile Rd, Royal Oak, MI 48073 USA
关键词
Midline catheter; Thrombosis; Deep vein thrombosis; Catheter related thrombosis; Complications; Catheter to vein ratio; Diameter; Gauge;
D O I
10.1016/j.thromres.2023.06.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Deep vein thrombosis is a common and serious complication associated with midline catheters (MC). The aim of this investigation was to determine if catheter diameter is related to development of thrombosis.Methods: This was an observational cohort study conducted at a tertiary care academic center in Southeastern Michigan. Hospitalized adults that required a MC were eligible participants. Primary outcome was symptomatic MC associated upper extremity deep vein thrombosis (DVT) comparing three catheter diameters. Secondary outcomes included complications based on size and DVT comparing catheter to vein ratio.Results: Between January 1, 2017, and December 31, 2021, 3088 MCs met inclusion criteria; the distribution of 3 French (Fr), 4 Fr, and 5 Fr MCs was 35.1 %, 57.0 %, and 7.9 %, respectively. The majority of the population was female (61.2 %) and the average age was 64.2 years old. DVT occurred in 4.4 %, 3.9 %, and 11.9 % of 3 Fr, 4 Fr, and 5 Fr MCs, respectively (p < 0.001). In multivariable regression analysis, there was no difference in the odds of developing DVT for the 4 Fr MC compared to the 3 Fr (aOR 0.88; 95 % CI 0.59-1.31; p = 0.5243), however, there was significantly higher odds for the 5 Fr (aOR 2.72; 95 % CI 1.62-4.51; p = 0.001). Additionally, for every additional day the MC was in place, the odds of DVT increased by 3 % (aOR 1.03; 95 % CI 1.01-1.05; p = 0.0039). When comparing accuracy of the size model versus catheter to vein ratio model for predicting DVT, receiver operating characteristic curve analysis demonstrated the area under the curve for size was 73.70 % (95 % CI 68.04 %-79.36 %) compared to 73.01 % (95 % CI: 66.88 %-79.10 %) for catheter-to-vein ratio. Conclusions: Smaller diameter catheters should be preferentially chosen to mitigate the risk of thrombosis when therapy via midline catheters is required. Choosing a catheter based on reduced size or 1:3 catheter to vein ratio threshold has similar accuracy in predicting DVT.
引用
收藏
页码:172 / 180
页数:9
相关论文
共 26 条
[1]   Ultrasound-Guided Peripheral Intravenous Catheter Insertion Training Reduces Use of Midline Catheters in Hospitalized Patients With Difficult Intravenous Access [J].
Amick, Ashley E. ;
Feinsmith, Sarah E. ;
Sell, Jordan ;
Davis, Evan M. ;
Wayne, Diane B. ;
Feinglass, Joseph ;
Barsuk, Jeffrey H. .
JOURNAL OF PATIENT SAFETY, 2022, 18 (03) :E697-E703
[2]  
Bahl A., 2022, SSRN ELECT J, DOI [10.2139/SSRN.4020150, DOI 10.2139/SSRN.4020150]
[3]   Comparison of 2 Midline Catheter Devices With Differing Antithrombogenic Mechanisms for Catheter-Related Thrombosis A Randomized Clinical Trial [J].
Bahl, Amit ;
Diloreto, Emily ;
Jankowski, David ;
Hijazi, Mahmoud ;
Chen, Nai-Wei .
JAMA NETWORK OPEN, 2021, 4 (10)
[4]   Comparison of Venous Thrombosis Complications in Midlines Versus Peripherally Inserted Central Catheters: Are Midlines the Safer Option? [J].
Bahl, Amit ;
Karabon, Patrick ;
Chu, David .
CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2019, 25
[5]  
Bing Shaoxu, 2022, Am J Surg, V223, P983, DOI 10.1016/j.amjsurg.2021.09.029
[6]   Safe administration of vancomycin through a novel midline catheter: a randomized, prospective clinical trial [J].
Caparas, Jona V. ;
Hu, Jian-Ping .
JOURNAL OF VASCULAR ACCESS, 2014, 15 (04) :251-256
[7]   Variation in use and outcomes related to midline catheters: results from a multicentre pilot study [J].
Chopra, Vineet ;
Kaatz, Scott ;
Swaminathan, Lakshmi ;
Boldenow, Tanya ;
Snyder, Ashley ;
Burris, Rachel ;
Bernstein, Steve J. ;
Flanders, Scott .
BMJ QUALITY & SAFETY, 2019, 28 (09) :714-720
[8]   Ultrasound-guided tip location of midline catheters [J].
Elli, Stefano ;
Pittiruti, Mauro ;
Pigozzo, Valentina ;
Cannizzo, Luigi ;
Giannini, Luciano ;
Siligato, Andrea ;
Rondelli, Egle ;
Foti, Giuseppe ;
Lucchini, Alberto .
JOURNAL OF VASCULAR ACCESS, 2020, 21 (05) :764-768
[9]   Section One: Infusion Therapy Practice [J].
不详 .
JOURNAL OF INFUSION NURSING, 2021, 44 :S13-S42
[10]  
Gorski LA, 2017, J INFUS MURS, V40, P26, DOI 10.1097/NAN.0000000000000202