A Novel Computation of Delay Margin Based on Grey Wolf Optimisation for a Load Frequency Control of Two-Area-Network Power Systems

被引:3
|
作者
Ibrahim, Mohammad Haziq [1 ]
Peng, Ang Swee [1 ]
Dani, Muhammad Norfauzi [1 ]
Khalil, Ashraf [2 ]
Law, Kah Haw [1 ]
Yunus, Sharina [1 ]
Rahman, Mohammad Ishlah [3 ]
Au, Thien Wan [4 ]
机构
[1] Univ Teknol Brunei, Elect & Elect Engn Programme Area, BE-1410 Bandar Seri Begawan, Brunei
[2] Tech Univ Denmark, DTU Engn Technol, DK-2750 Ballerup, Denmark
[3] Minist Educ, Politeknik Brunei, Sch Sci & Engn, Bandar Seri Begawan, Brunei
[4] Univ Teknol Brunei, Sch Comp & Informat, BE-1410 Bandar Seri Begawan, Brunei
关键词
communication time delay; delay margin; delay dependent stability; grey wolf optimisation; two-area load-frequency control; DEPENDENT STABILITY; LINEAR-SYSTEMS; CONSTANT; CRITERIA;
D O I
10.3390/en16062860
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In classical power systems, frequency measurements are transferred via a specialised communication channel, resulting in time delay. The time delay plays a major role in a power system, which can reduce the dynamic performance of the load-frequency control (LFC) system and can destabilise the system. The research to date has tended to focus on developing a new algorithm to determine the delay margin (DM) rather than looking into a hybrid algorithm which includes a nature-inspired metaheuristic optimisation technique. This paper introduces a novel method for computing the DM based on grey wolf optimisation (GWO), specifically for the constant time delay. In the proposed method, GWO is employed to optimise the minimum error of the spectral radius and to determine the best design variable of the crossing frequency. With the help of the proposed method, the sweeping range is no longer required, which improves the accuracy of the result. To evaluate the proposed method, a two-area network power system is considered as a case study. Furthermore, the effect of the PI controller gains on the DM is taken into account. The proposed method efficacy is demonstrated by comparing it with the most recently published methods. The results demonstrate that the proposed method is remarkably better than the existing methods found in the literature, where the smallest percentage inaccuracy using the simulation-based DM based on GWO is found to be 0.000%.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] An Analytical Design Method of PI/PID Load Frequency Controllers for Single-Area Power System with Communication Network Time Delay
    Boskovic, Marko C.
    Sekara, Tomislav B.
    Rapaic, Milan R.
    2021 20TH INTERNATIONAL SYMPOSIUM INFOTEH-JAHORINA (INFOTEH), 2020,
  • [42] H∞ Performance-Based Sliding Mode Control Approach for Load Frequency Control of Interconnected Power System with Time Delay
    Pradhan, Subrat Kumar
    Das, Dushmanta Kumar
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2021, 46 (02) : 1369 - 1382
  • [43] LMI-Based Robust Predictive Load Frequency Control for Power Systems With Communication Delays
    Ojaghi, Pegah
    Rahmani, Mehdi
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (05) : 4091 - 4100
  • [44] Computation of stability regions for time-delayed two-area load frequency control system including dynamic demand response
    Katipoglu, Deniz
    Sonmez, Sahin
    Ayasun, Saffet
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2024, 39 (01): : 431 - 442
  • [45] Further Improvement on Delay-Dependent Load Frequency Control of Power Systems via Truncated B-L Inequality
    Yang, Feisheng
    He, Jing
    Pan, Quan
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (05) : 5062 - 5071
  • [46] Computation of PI Controllers Ensuring Desired Gain and Phase Margins for Two-Area Load Frequency Control System with Communication Time Delays
    Sonmez, Sahin
    Ayasun, Saffet
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2018, 46 (08) : 938 - 947
  • [47] Gain and phase margins based delay-dependent stability analysis of single-area load frequency control system with constant communication time delay
    Sonmez, Sahin
    Ayasun, Saffet
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2018, 40 (05) : 1701 - 1710
  • [48] Event-Triggered $H_{∞}$ Load Frequency Control for Multi-Area Nonlinear Power Systems Based on Non-Fragile Proportional Integral Control Strategy
    Zhong, Qishui
    Yang, Jin
    Shi, Kaibo
    Zhong, Shouming
    Li, Zhixiong
    Sotelo, Miguel Angel
    IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2022, 23 (08) : 12191 - 12201
  • [49] Delay-dependent stability analysis of a two-area load frequency control system including electric vehicle aggregator and dynamic demand response
    Tek, Bilal
    Sonmez, Sahin
    Ayasun, Saffet
    2020 12TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO), 2020, : 178 - 182
  • [50] Dynamic Event-Triggered ${H}_{∞ }$ Load Frequency Control for Multi-Area Power Systems Subject to Hybrid Cyber Attacks
    Wang, Jing
    Wang, Dongji
    Su, Lei
    Park, Ju H.
    Shen, Hao
    IEEE TRANSACTIONS ON SYSTEMS MAN CYBERNETICS-SYSTEMS, 2022, 52 (12): : 7787 - 7798