A Novel Computation of Delay Margin Based on Grey Wolf Optimisation for a Load Frequency Control of Two-Area-Network Power Systems

被引:3
|
作者
Ibrahim, Mohammad Haziq [1 ]
Peng, Ang Swee [1 ]
Dani, Muhammad Norfauzi [1 ]
Khalil, Ashraf [2 ]
Law, Kah Haw [1 ]
Yunus, Sharina [1 ]
Rahman, Mohammad Ishlah [3 ]
Au, Thien Wan [4 ]
机构
[1] Univ Teknol Brunei, Elect & Elect Engn Programme Area, BE-1410 Bandar Seri Begawan, Brunei
[2] Tech Univ Denmark, DTU Engn Technol, DK-2750 Ballerup, Denmark
[3] Minist Educ, Politeknik Brunei, Sch Sci & Engn, Bandar Seri Begawan, Brunei
[4] Univ Teknol Brunei, Sch Comp & Informat, BE-1410 Bandar Seri Begawan, Brunei
关键词
communication time delay; delay margin; delay dependent stability; grey wolf optimisation; two-area load-frequency control; DEPENDENT STABILITY; LINEAR-SYSTEMS; CONSTANT; CRITERIA;
D O I
10.3390/en16062860
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In classical power systems, frequency measurements are transferred via a specialised communication channel, resulting in time delay. The time delay plays a major role in a power system, which can reduce the dynamic performance of the load-frequency control (LFC) system and can destabilise the system. The research to date has tended to focus on developing a new algorithm to determine the delay margin (DM) rather than looking into a hybrid algorithm which includes a nature-inspired metaheuristic optimisation technique. This paper introduces a novel method for computing the DM based on grey wolf optimisation (GWO), specifically for the constant time delay. In the proposed method, GWO is employed to optimise the minimum error of the spectral radius and to determine the best design variable of the crossing frequency. With the help of the proposed method, the sweeping range is no longer required, which improves the accuracy of the result. To evaluate the proposed method, a two-area network power system is considered as a case study. Furthermore, the effect of the PI controller gains on the DM is taken into account. The proposed method efficacy is demonstrated by comparing it with the most recently published methods. The results demonstrate that the proposed method is remarkably better than the existing methods found in the literature, where the smallest percentage inaccuracy using the simulation-based DM based on GWO is found to be 0.000%.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Delay-Dependent Stability of Load Frequency Control in Networked Power Systems Integrated with Electric Vehicles
    Ramakrishnan, K.
    Jawahar, A.
    CONTROL ENGINEERING AND APPLIED INFORMATICS, 2022, 24 (03): : 40 - 49
  • [32] Decentralized Networked Load Frequency Control in Interconnected Power Systems Based on Stochastic Jump System Theory
    Yang, Ting
    Zhang, Yajian
    Li, Wei
    Zomaya, Albert Y.
    IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (05) : 4427 - 4439
  • [33] Impact of participation ratios on the stability delay margins computed by direct method for multiple-area load frequency control systems with demand response
    Katipoglu, Deniz
    Sonmez, Sahin
    Ayasun, Saffet
    Naveed, Ausnain
    AUTOMATIKA, 2022, 63 (01) : 185 - 197
  • [34] Resilient Load Frequency Control of Power Systems to Compensate Random Time Delays and Time-Delay Attacks
    Shangguan, Xing-Chen
    He, Yong
    Zhang, Chuan-Ke
    Yao, Wei
    Zhao, Yifan
    Jiang, Lin
    Wu, Min
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (05) : 5115 - 5128
  • [35] Protocol-Based Load Frequency Control for Power Systems With Nonhomogeneous Sojourn Probabilities
    Cheng, Jun
    Xu, Jiangming
    Park, Ju H. H.
    Basin, Michael V. V.
    IEEE TRANSACTIONS ON SYSTEMS MAN CYBERNETICS-SYSTEMS, 2023, 53 (09): : 5742 - 5750
  • [36] Computation of Delay Margin in a Power System Having Open Channel Communication Based Automatic Generation Control using Pade Approximation
    Sharma, Dushyant
    Mishra, Sukumar
    Firdaus, Ayesha
    2019 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2019 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2019,
  • [37] Sampled-data based discrete and fast load frequency control for power systems with wind power
    Xingchen Shang-Guan
    He, Yong
    Zhang, Chuanke
    Jiang, Lin
    Spencer, Joseph William
    Wu, Min
    APPLIED ENERGY, 2020, 259
  • [38] Event-triggered load frequency control for multi-area power systems based on Markov model: a global sliding mode control approach
    Lv, Xinxin
    Sun, Yonghui
    Cao, Shiqi
    Dinavahi, Venkata
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (21) : 4878 - 4887
  • [39] Event-triggering load frequency control for multi-area power system based on random dynamic triggering mechanism and two-side closed functional?
    Liu, Xingyue
    Shi, Kaibo
    Ma, Changyou
    Tang, Yiqian
    Tang, Lin
    Wei, Youhua
    Han, Yingjun
    ISA TRANSACTIONS, 2023, 133 : 193 - 204
  • [40] A Comparative Hybrid Optimisation Analysis of Load Frequency Control in a Single Area Power System Using Metaheuristic Algorithms and Linear Quadratic Regulator
    Ibrahim, M. H.
    Ang, S. P.
    Hamid, Zainidi
    Mohammed, S. Sheik
    Law, Kah Haw
    2022 INTERNATIONAL CONFERENCE ON GREEN ENERGY, COMPUTING AND SUSTAINABLE TECHNOLOGY (GECOST), 2022, : 232 - 237