Experimental study on behavior of top-and-seat-angle with double web-angle (TSDW) connections under fire conditions

被引:6
作者
Cao, Yifan [1 ]
Lu, Yaoliang [1 ]
Jiang, Jian [2 ]
Chen, Wei [2 ]
Ye, Jihong [2 ]
机构
[1] China Univ Min & Technol, Xuzhou 221116, Jiangsu, Peoples R China
[2] China Univ Min & Technol, Jiangsu Key Lab Environm Impact & Struct Safety En, Xuzhou 221116, Peoples R China
基金
中国国家自然科学基金;
关键词
Top -and -seat -angle with double web -angle; connections; Fire; Experiment; Failure mode; Full-scale; Angle thickness; Stiffener; SHEAR BOLTED CONNECTIONS; THIN SHEET STEELS; COLUMN CONNECTIONS; CLEAT CONNECTIONS; WELDED CONNECTION; TYING CAPACITY; BEAM; JOINTS; TESTS; PERFORMANCE;
D O I
10.1016/j.tws.2023.111304
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel beam-to-column connections are more prone to fracture due to tension in the heating and cooling phase of a fire, imposing an important issue on progressive collapse of steel structures in fire. Experiments are conducted in this study on four top-and-seat-angle with double web-angle (TSDW) connections under room-temperature, heating, heating-cooling and after-fire conditions. The effect of temperature histories and loading states on the failure modes and displacement curves of connections is investigated. A numerical model of full-scale TSDW connections is established and validated, and parametric studies are carried out to study the effect of scale ratios, material properties, angle thickness and stiffeners. The experimental results show that the connection may fail due to tearing of bolt holes or shear failure of bolts in the seat angle. The critical temperature of connections is 710 degrees C for a load ratio of 0.5, and its residual capacity reduces by 23 % after experiencing a maximum temperature of 980 degrees C. Loading during fire has a significant effect (60 %) on the residual capacity of connections after fire. It is found from numerical simulation that the scale ratio affects failure modes, critical temperatures, residual capacities and failure displacements of connections, and further work is still needed to quantify structural fire similarity. The yield strength and fracture strain are important factors affecting the behavior of steel connections at both ambient and elevated temperatures. Increasing the angle thickness and applying stiffeners can effectively improve the load-bearing capacity of TSDW connections at room temperature. There is an optimal angle thickness (e.g., 8 mm) for improving residual capacity of connections, and the selection of stiffeners should consider its matching with angles. It is recommended to exclude stiffeners for thick angles (e.g., 12 mm) to avoid adverse effect on the fire resistance and post-fire residual capacity of TSDW connections.
引用
收藏
页数:17
相关论文
共 57 条
[1]   Numerical study of top-and seat-angle with double web-angle connection with high-strength steel [J].
AlHendi, H. ;
Mahmoud, M. ;
Celikag, M. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 174
[2]  
[Anonymous], 2005, Eurocode 3: Design of Steel Structures, Part 1-2: General Rules - Structural Fire Design
[3]  
[Anonymous], 2005, EN 1993-1-8
[4]  
[Anonymous], 2016, PROGRESSIVE COLLAPSE
[5]  
[Anonymous], 2022, ANSI/AISC 360-22
[6]  
[Anonymous], 2017, GB51249, Code for Fire Safety of Steel Structures in Buildings
[7]   Effects of end distance on thin sheet steel single shear bolted connections at elevated temperatures [J].
Cai, Yancheng ;
Young, Ben .
THIN-WALLED STRUCTURES, 2020, 148
[8]   Bearing factors of cold-formed stainless steel double shear bolted connections at elevated temperatures [J].
Cai, Yancheng ;
Young, Ben .
THIN-WALLED STRUCTURES, 2016, 98 :212-229
[9]   Behavior of cold-formed stainless steel single shear bolted connections at elevated temperatures [J].
Cai, Yancheng ;
Young, Ben .
THIN-WALLED STRUCTURES, 2014, 75 :63-75
[10]   Methods of improving survivability of steel beam/column connections in fire [J].
Chen, L. ;
Wang, Y. C. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 79 :127-139