LC-MS/MS methods for the determination of 30 quaternary ammonium compounds including benzalkonium and paraquat in human serum and urine

被引:18
|
作者
Li, Zhong-Min [1 ,2 ]
Lakuleswaran, Mathusa [1 ,2 ]
Kannan, Kurunthachalam [1 ,2 ,3 ]
机构
[1] New York Univ Grossman Sch Med, Dept Pediat, New York, NY 10016 USA
[2] New York Univ Grossman Sch Med, Dept Environm Med, New York, NY 10016 USA
[3] MSB 6-698,550 First Ave, New York, NY 10016 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2023年 / 1214卷
关键词
Benzalkonium; Quaternary ammonium compound; Paraquat; Serum; Urine; Disinfectant; Exposure; Carboxylic benzalkonium; TANDEM MASS-SPECTROMETRY; HERBICIDES PARAQUAT; HIGH-RESOLUTION; COMPOUNDS QACS; DIQUAT; PLASMA; QUANTIFICATION; IDENTIFICATION; VEGETABLES; TOXICITY;
D O I
10.1016/j.jchromb.2022.123562
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Benzalkyldimethylammonium (or benzalkonium; BACs), alkyltrimethylammonium (ATMACs), and dia-lkyldimethylammonium compounds (DDACs) have been widely used for over six decades as disinfectants, especially during the COVID-19 pandemic. Here we describe methods for the determination of 7 BACs, 6 ATMACs, 6 DDACs, 8 BAC metabolites, and the structurally similar quaternary ammonium compound (QAC) herbicides diquat, paraquat, and difenzoquat in human serum and urine using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The methods were optimized using isotopically labelled internal standards and solid-phase extraction with weak cation-exchange cartridges. We separated diquat and paraquat chro-matographically using a mixed-mode LC column, and BACs, ATMACs, DDACs, difenzoquat, and BAC metabolites using reversed-phase (C8 and C18) LC columns. Method limits of detection (MLODs) and quantification (MLOQs) were 0.002-0.42 and 0.006-1.40 ng/mL, respectively. Recoveries of all analytes fortified at 1, 5, and 20 ng/mL concentrations in serum and urine matrices were 61-129%, with standard deviations of 0-20%. Repeated analysis of similarly fortified serum and urine samples yielded intra-day and inter-day variations of 0.22-17.4% and 0.35-17.3%, respectively. Matrix effects for analytes spiked into serum and urine matrices ranged from -27% to 15.4%. Analysis of real urine and serum samples revealed the presence of several QACs in human serum. Although no parent BACs were found in urine, we detected, for the first time, several to-hydroxy and to-carboxylic acid metabolites of BACs at average concentrations in the range of 0.05-0.35 ng/mL. The developed method is suitable for application in large-scale biomonitoring of human exposure to QACs and their metabolites in human serum and urine.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Validation of LC-MS/MS method for determination of ertapenem in human plasma and urine
    Kim, Yun-Jeong
    Han, Song-Hee
    Jeon, Ji-Young
    Hwang, Min-Ho
    Im, Yong-Jin
    Chae, Soo-Wan
    Kim, Min-Gul
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2012, 25 (01): : 19 - 24
  • [22] LC-MS/MS determination of a farnesyl transferase inhibitor in human plasma and urine
    DePuy, ME
    Musson, DG
    Yu, S
    Fisher, AL
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (04) : 1157 - 1171
  • [23] Detection of bisphenol A in human urine by LC-MS/MS
    Völkel, W
    Bittner, N
    Dekant, W
    TOXICOLOGY AND APPLIED PHARMACOLOGY, 2004, 197 (03) : 190 - 190
  • [24] Development of an LC-MS/MS Method for Simultaneous Determination of the Quaternary Ammonium Herbicides Paraquat, Diquat, Chlormequat, and Mepiquat in Plant-Derived Commodities
    Anna Bauer
    Jens Luetjohann
    Sascha Rohn
    Jürgen Kuballa
    Eckard Jantzen
    Food Analytical Methods, 2018, 11 : 2237 - 2243
  • [25] Development of an LC-MS/MS Method for Simultaneous Determination of the Quaternary Ammonium Herbicides Paraquat, Diquat, Chlormequat, and Mepiquat in Plant-Derived Commodities
    Bauer, Anna
    Luetjohann, Jens
    Rohn, Sascha
    Kuballa, Jurgen
    Jantzen, Eckard
    FOOD ANALYTICAL METHODS, 2018, 11 (08) : 2237 - 2243
  • [26] METABOLITE PROFILING OF MZ IN MOUSE, RAT AND HUMAN URINE BY LC-MS AND LC-MS/MS
    Li, Li
    Tian, Dandan
    Li, Chuan
    DRUG METABOLISM REVIEWS, 2008, 40 : 135 - 135
  • [27] Determination of boldenone in postmortem specimens including blood and urine samples using LC-MS/MS
    Park, Meejung
    Sim, Juhyun
    Jeon, Youngjoon
    Yeon, Seonghoon
    Lee, Jaesin
    In, Sangwhan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 169 : 111 - 115
  • [28] Uncertainty evaluation for the determination of creatinine in urine by LC-MS/MS
    Kim, Jin Young
    Kwon, Woonyong
    Suh, SungIll
    In, Moon Kyo
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2012, 25 (01): : 83 - 90
  • [29] Validated LC-MS/MS methods for the determination of risperidone and the enantiomers of 9-hydroxyrisperidone in human plasma and urine
    De Meulder, Marc
    Remmerie, Bart M. M.
    de Vries, Ronald
    Sips, Luc L. A.
    Boom, Sandra
    Hooijschuur, Edwin W. J.
    van de Merbel, Nico C.
    Timmerman, Philip M. M. B. L.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 870 (01): : 8 - 16
  • [30] Determination of Clenbuterol in Various Edible Parts of Livestock Products by LC-MS/MS and LC-MS/MS/MS Methods
    HAYASHI, Takako
    HAMASE, Kenji