Toward a More Comprehensive Approach for Dissolved Organic Matter Chemical Characterization Using an Orbitrap Fusion Tribrid Mass Spectrometer Coupled with Ion and Liquid Chromatography Techniques

被引:3
作者
Bergmann, Daniela [1 ]
Matarrita-Rodriguez, Jessie [1 ,2 ]
Abdulla, Hussain [1 ,3 ]
机构
[1] Texas A&M Univ Corpus Christi, Dept Phys & Environm Sci, Corpus Christi, TX 78412 USA
[2] Univ Costa Rica, Ctr Invest Contaminac Ambiental CICA, San Jose 115012060, Costa Rica
[3] Texas A&M Univ Corpus Christi, Ctr Water Supply Studies, Corpus Christi, TX 78412 USA
基金
美国国家科学基金会;
关键词
MOLECULAR CHARACTERIZATION; MS; METABOLITES; ACCURACY; CALIBRATION; VALIDATION; EXTRACTION; INJECTION; STANDARD; DOM;
D O I
10.1021/acs.analchem.3c02599
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dissolved organic matter (DOM) represents one of the largest active organic carbon pools in the global carbon cycle. Although extensively studied, only <10% of DOM has been chemically characterized into individual dissolved compounds due to its molecular complexity. This study introduced a more comprehensive DOM characterization method by coupling both ion chromatography (IC) and liquid chromatography (LC) with high mass accuracy and resolution mass spectrometry. We presented a new on-the-fly mass calibration of the Orbitrap technique by utilizing the "lock mass" function in the Orbitrap Fusion Tribrid mass spectrometer (OT-FTMS), which assures high mass accuracy at every scan by a postcolumn introduction of internal labeled standards. With both IC and LC, tested unlabeled standards of amino acids, small peptides, and organic acids were consistently below 1.0 ppm mass error, giving the OT-FTMS the potential of reaching mass accuracy of the Fourier-transform ion cyclotron resonance mass spectrometer. In addition to mass accuracy, a pooled quality control sample (QC) was used to increase reproducibility by applying systematic error removal using random forest (SERRF). Using an untargeted mass spectrometry approach, estuarine DOM samples were analyzed by OT-FTMS coupled to IC in negative mode and LC in positive mode detection to cover a wide range of highly cationic to highly anionic molecules. As a proof of concept, we focused on elucidating the structures of three distinct DOM compound classes with varied acidities and basicities. In UPLC-OT-FTMS, a total of 915 compounds were detected. We putatively elucidated 44 small peptides and 33 deaminated peptides of these compounds. With IC-OT-FTMS, a total of 1432 compounds were detected. We putatively elucidated 20 peptides, 268 deaminated peptides, and 188 organic acids. Except for five compounds, all putatively elucidated compounds were uniquely detected in their corresponding chromatography technique. These results highlight the need for combining these two techniques to provide a more comprehensive method for DOM characterization. Application of the combined IC and LC techniques is not limited to DOM chemical characterization. It can analyze other complex compound mixtures, such as metabolites, and anthropogenic pollutants, such as pesticides and endocrine-disrupting chemicals, in environmental and biological samples.
引用
收藏
页码:3744 / 3753
页数:10
相关论文
共 45 条
  • [1] Accumulation of deaminated peptides in anoxic sediments of Santa Barbara Basin
    Abdulla, Hussain A.
    Burdige, David J.
    Komada, Tomoko
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2018, 223 : 245 - 258
  • [2] [Anonymous], 2015, Acceptance Criteria for Confirmation of Identity of Chemical Residues using Exact Mass Data for the FDA Foods and Veterinary Medicine Program
  • [3] Correction of mass calibration gaps in liquid chromatography-mass spectrometry metabolomics data
    Benton, H. Paul
    Want, Elizabeth J.
    Ebbels, Timothy M. D.
    [J]. BIOINFORMATICS, 2010, 26 (19) : 2488 - 2489
  • [4] Guidelines and considerations for the use of system suitability and quality control samples in mass spectrometry assays applied in untargeted clinical metabolomic studies
    Broadhurst, David
    Goodacre, Royston
    Reinke, Stacey N.
    Kuligowski, Julia
    Wilson, Ian D.
    Lewis, Matthew R.
    Dunn, Warwick B.
    [J]. METABOLOMICS, 2018, 14 (06)
  • [5] Semi-targeted analysis of metabolites using capillary-flow ion chromatography coupled to high-resolution mass spectrometry
    Burgess, Karl
    Creek, Darren
    Dewsbury, Paul
    Cook, Ken
    Barrett, Michael P.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (22) : 3447 - 3452
  • [6] Flow injection of the lock mass standard for accurate mass measurement in electrospray ionization time-of-flight mass spectrometry coupled with liquid chromatography
    Charles, L
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (13) : 1383 - 1388
  • [7] Comprehensive Lists of Internal Calibrants for Ultrahigh-Resolution Mass Spectrometry Analysis of Crude Oil and Natural Organic Matter and Their Preparation Recipes
    Cho, Eunji
    Solihat, Nissa Nurfajrin
    Kim, Young Hwan
    Kim, Sunghwan
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (02) : 590 - 596
  • [8] Scaling and normalization effects in NMR spectroscopic metabonomic data sets
    Craig, A
    Cloareo, O
    Holmes, E
    Nicholson, JK
    Lindon, JC
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (07) : 2262 - 2267
  • [9] A simple and efficient method for the solid-phase extraction of dissolved organic matter (SPE-DOM) from seawater
    Dittmar, Thorsten
    Koch, Boris
    Hertkorn, Norbert
    Kattner, Gerhard
    [J]. LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2008, 6 : 230 - 235
  • [10] Optimization of Resolving Power, Fragmentation, and Mass Calibration in an Orbitrap Spectrometer for Analysis of 24 Pesticide Metabolites in Urine
    Dualde, Pablo
    Coscolla, Clara
    Pastor, Agustin
    Yusa, Vicent
    [J]. INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 2019