The impact of tube bundle layout on the thermal and fluidic behaviour of liquid lead-bismuth eutectic in a helical-coiled once-through steam generator

被引:2
作者
Nuhash, Mashrur Muntasir [1 ]
Karim, Md Rezwanul [1 ]
Bhuiyan, Arafat A. [1 ]
机构
[1] Islamic Univ Technol IUT, Dept Mech & Prod Engn MPE, Gazipur 1704, Bangladesh
关键词
Liquid metal; Lead-bismuth eutectic; Heat transfer; Computational fluid dynamics; Helically-coiled once through steam generator; PRANDTL-NUMBER MODELS; TURBULENT-PRANDTL; HEAT-TRANSFER; APPLICABILITY; FLOWS;
D O I
10.1016/j.heliyon.2024.e24149
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study introduces a numerical model to assess the thermal and frictional properties of LBE crossflow over tube bundles on the shell side of a Helical-coiled Once-Through Steam Generator (H-OTSG) considering different arrangements, including inline, obliquely staggered, triangular, and rotated square configurations. The k-omega SST turbulence model combined with Kays turbulent Prandtl number model is utilized to develop the numerical model. The simulation results have been validated against experimental data and empirical correlations. The layouts of the tube bundles significantly influence the generation of transverse flow, vortical structures and rate of heat transfer in the flow domain. The maximum Nusselt number of 8.2 is observed for the triangular layout as significant crossflow is induced, which is a 10% increase compared to the inline arrangement where the Nusselt number is 7.45. Triangle layouts also exhibit a higher friction factor of 0.45, marking a 20% increase compared to the 0.45 friction factor observed in the inline arrangement. Increasing the oblique angle usually reduces the heat transfer rate and friction factor. Yet, at a 45-degree layout, higher turbulence intensity results in a Nu of 7.05, surpassing 6.93 observed at 30 degrees but falling short of 7.15 at 15 degrees. Nu decreases for rotated square arrangements, but a friction factor greater than the inline arrangement is observed at higher diagonal pitches. The Thermal Enhancement Factor (THEF) is employed to assess the thermal effectiveness of the different tube bundle layouts, and the maximum THEF of 1.1 is observed for the layout with an oblique angle of 45 degrees. Favorable THEF values of 1.06 and 1.05 are recorded for the triangular layout and 30-degree oblique angle, respectively. This numerical study will assist the design and development of LBE H-OTSG.
引用
收藏
页数:13
相关论文
共 39 条
  • [1] The Effects of Reduced Gravity and Radiative Heat Transfer on the Magnetohydrodynamic Flow Past a Non-Rotating Stationary Sphere Surrounded by a Porous Medium
    Abbas, Amir
    Sarris, Ioannis E.
    Ashraf, Muhammad
    Ghachem, Kaouther
    Hnaien, Nidhal
    Alshammari, Badr M.
    [J]. SYMMETRY-BASEL, 2023, 15 (04):
  • [2] Computational analysis of Darcy-Forchheimer relation, reduced gravity, and external applied magnetic field influence on radiative fluid flow and heat transfer past a sphere: Finite difference method
    Abbas, Amir
    Ashraf, Muhammad
    Ahmad, Hafeez
    Ghachem, Kaouther
    Ullah, Zia
    Hussanan, Abid
    Labidi, Taher
    Kolsi, Lioua
    [J]. HELIYON, 2023, 9 (05)
  • [3] Magnetohydrodynamic Bioconvective Flow of Williamson Nanofluid over a Moving Inclined Plate Embedded in a Porous Medium
    Abbas, Amir
    Khandelwal, Radhika
    Ahmad, Hafeez
    Ilyas, Asifa
    Ali, Liaqat
    Ghachem, Kaouther
    Hassen, Walid
    Kolsi, Lioua
    [J]. MATHEMATICS, 2023, 11 (04)
  • [4] Solar radiation over a roof in the presence of temperature-dependent thermal conductivity of a Casson flow for energy saving in buildings
    Abbas, Amir
    Noreen, Asma
    Ali, Masood Ashraf
    Ashraf, Muhammad
    Alzahrani, Eman
    Marzouki, Riadh
    Goodarzi, M.
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 53
  • [5] Abramov Alexey G., 2015, ST PETERSBURG POLYTE, V1, P356
  • [6] Study of structural features and thermal properties of barium hexaferrite upon indium doping
    Agayev, F. G.
    Trukhanov, S., V
    Trukhanov, An, V
    Jabarov, S. H.
    Ayyubova, G. Sh
    Mirzayev, M. N.
    Trukhanova, E. L.
    Vinnik, D. A.
    Kozlovskiy, A. L.
    Zdorovets, M., V
    Sombra, A. S. B.
    Zhou, Di
    Jotania, R. B.
    Singh, C.
    Trukhanov, A., V
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (24) : 14107 - 14114
  • [7] Modeling the total heat transfer coefficient of a nuclear research reactor cooling system by different methods
    Akay, Orhan Erdal
    Das, Mehmet
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2021, 25
  • [8] [Anonymous], 2015, Handbook on Lead-bismuth Eutectic Alloy and Lead Properties, Materials Compatibility, Thermal- Hydraulics and Technologies
  • [9] Influence of stepped cylindrical turbulence generators on the thermal enhancement factor of a flat plate solar air heater
    Antony, A. Leander
    Shetty, Shreyas P.
    Madhwesh, N.
    Sharma, N. Yagnesh
    Karanth, K. Vasudeva
    [J]. SOLAR ENERGY, 2020, 198 : 295 - 310
  • [10] Helical coil thermal-hydraulic model for supercritical lead cooled fast reactor steam generators
    Caramello, Marco
    Bertani, Cristina
    De Salve, Mario
    Panella, Bruno
    [J]. APPLIED THERMAL ENGINEERING, 2016, 101 : 693 - 698