Application of portable liquid scintillation counter for on-field measurement of tritium in aqueous samples during radiation emergency

被引:0
作者
Reddy, Priyanka J. [1 ]
Sankhla, Rajesh [1 ,2 ]
Chaudhury, Probal [1 ]
机构
[1] Bhabha Atom Res Ctr, Radiat Safety Syst Div, Mumbai 400085, India
[2] Homi Bhabha Natl Inst, Mumbai 400085, India
关键词
Curve fitting - Ethers - Ionization - Polyols - Scintillation - Scintillation counters - Screening - Tritium;
D O I
10.1016/j.jenvrad.2023.107330
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Screening of aqueous samples for H-3 contamination is required to decide suitability of water intended for human consumption during radiation emergency. BARC, Trombay has recently procured Portable Triathler liquid scintillation counter as a screening tool for on-site response to radiation emergency. For this purpose, parameters like, different available scintillators, scintillator to sample ratio and influence of different capacity scintillation vials were optimized for H-3 concentration measurement. The study indicated that for 7 mL vials, the optimized scintillator to sample ratio was 4:1 for Optiphase Hisafe II, Ultima Gold Ultra Low Level Tritium, Aqualight AB and Dioxane based scintillators whereas for Ultima Gold AB and Optiphase Hisafe III scintillators it was 3:1. In case of 20 mL vials, the ratio was optimized to 8:1 for all the above mentioned six scintillators. Additionally, the effect of applying counting efficiency using calibration curves generated using distilled water and that obtained using optimized scintillator to sample ratio in various spiked water samples was also studied. Results in H-3 concentration (2000-5700 Bq/mL) indicate about +/- 10% deviation using both the methods for commercially available scintillators. However, in case of Dioxane based scintillator, the deviation was higher (20%). For analysis of H-3 concentration similar to 200 Bq/mL using commercially available scintillators results in higher deviation of about 21% due to unreliable quench indicating parameter for count rate less than 4000. The study indicated that calibration curves constructed using optimized parameters are universally applicable for determination of H-3 concentration in wide variety of water samples.
引用
收藏
页数:9
相关论文
共 25 条
[1]  
Abesser C., 2009, Ground Water Resources Programme Open Report OR/09/006
[2]  
AERB Guidelines, 2014, AERB/NRF/SG/EP-5 (Rev.1)
[3]  
[Anonymous], 2014, IAEA/GNIP Precipitation Sampling Guide, P1
[4]   Tritium in surface waters of the Yenisei River basin [J].
Bolsunovsky, AY ;
Bondareva, LG .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2003, 66 (03) :285-294
[5]   Optimization of a portable liquid scintillation counting device for determining 222Rn in water [J].
Celaya, Santiago ;
Fuente, Ismael ;
Quindos, Luis ;
Sainz, Carlos .
RADIATION MEASUREMENTS, 2018, 117 :1-6
[7]   Measurement of tritium in the Sava and Danube Rivers [J].
Grahek, Zeljko ;
Breznik, Borut ;
Stojkovic, Ivana ;
Coha, Ivana ;
Nikolov, Jovana ;
Todorovic, Natasa .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2016, 162 :56-67
[8]   A portable liquid scintillation counter for general LSC and high sensitivity alpha-counting applications [J].
Haaslahti, J ;
Aalto, J ;
Oikari, T .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 243 (02) :377-381
[9]   Observed half-lives of 3H, 90Sr and 137Cs in hydrosphere in the Vltava River basin (Bohemia) [J].
Hanslík, E ;
Jedináková-Krízová, V ;
Ivanovová, D ;
Kalinová, E ;
Sedlárová, B ;
Simonek, P .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2005, 81 (2-3) :307-320
[10]   Concentration of radionuclides in hydrosphere affected by Temelin Nuclear Power Plant in Czech Republic [J].
Hanslik, E. ;
Ivanovova, D. ;
Jedinakova-Krizova, V. ;
Juranova, E. ;
Simonek, P. .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2009, 100 (07) :558-563